Dosimetric impact of baseline shift plan in a magnetic resonance linear accelerator according to target motion and plan characteristics

IF 2.5 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Shohei Tanaka, Noriyuki Kadoya, Yoshiyuki Takahashi, Seiya Koga, Yoshiyuki Katsuta, Kazuhiro Arai, Taichi Hoshino, Yushan Xiao, Wingyi Lee, Noriyoshi Takahashi, Rei Umezawa, Keiichi Jingu
{"title":"Dosimetric impact of baseline shift plan in a magnetic resonance linear accelerator according to target motion and plan characteristics","authors":"Shohei Tanaka,&nbsp;Noriyuki Kadoya,&nbsp;Yoshiyuki Takahashi,&nbsp;Seiya Koga,&nbsp;Yoshiyuki Katsuta,&nbsp;Kazuhiro Arai,&nbsp;Taichi Hoshino,&nbsp;Yushan Xiao,&nbsp;Wingyi Lee,&nbsp;Noriyoshi Takahashi,&nbsp;Rei Umezawa,&nbsp;Keiichi Jingu","doi":"10.1002/acm2.70861","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Purpose</h3>\n \n <p>In this study, the dosimetric effect of baseline shift (BLS) in a magnetic resonance linear accelerator was investigated and compared with adapt-to-position (ATP), adapt-to-shape (ATS), and an uncorrected plan without adaptation.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>In a simulation dataset consisting of 30 patients (10 prostate, 10 liver, 10 pancreatic), all structures were rigidly shifted by 1, 3, 5, and 10 mm separately in the superior–inferior and posterior directions, and four plans (ATS reoptimization, ATP reoptimization, BLS using the segment aperture morphing algorithm, and an uncorrected plan without adaptation) were generated for each shift condition. Planning target volume (PTV) coverage and PTV maximum dose (Dmax) were then compared. The dosimetric effects of BLS on the targets and organs at risk (OARs) under non-rigid anatomic changes were also evaluated using a clinical dataset based on magnetic resonance imaging acquired during treatment.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>In the simulation analysis of superior–inferior shifts, target coverage using BLS was comparable to that using ATS and ATP across all disease sites and improved compared with that using the uncorrected plan. For posterior shifts, target coverage remained comparable to that using ATS and ATP; however, BLS increased the PTV Dmax at all posterior shift magnitudes (1–10 mm) in prostate and pancreatic cases, with limited increases in liver cases. In the clinical dataset, OAR doses upon left–right or anterior–posterior displacement were greater using BLS than using ATP, ATS, and uncorrected plans in the prostate and pancreatic cases, with limited increases in the liver cases.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The dosimetric impact of BLS relies on motion direction and plan characteristics. BLS was stable for superior–inferior shifts, whereas posterior shifts may increase PTV hotspots and OAR doses. Therefore, clinical application of BLS should consider motion direction and plan design rather than applying a uniform strategy.</p>\n </section>\n </div>","PeriodicalId":14989,"journal":{"name":"Journal of Applied Clinical Medical Physics","volume":"27 11","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2026-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/acm2.70861","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Clinical Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/acm2.70861","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

In this study, the dosimetric effect of baseline shift (BLS) in a magnetic resonance linear accelerator was investigated and compared with adapt-to-position (ATP), adapt-to-shape (ATS), and an uncorrected plan without adaptation.

Methods

In a simulation dataset consisting of 30 patients (10 prostate, 10 liver, 10 pancreatic), all structures were rigidly shifted by 1, 3, 5, and 10 mm separately in the superior–inferior and posterior directions, and four plans (ATS reoptimization, ATP reoptimization, BLS using the segment aperture morphing algorithm, and an uncorrected plan without adaptation) were generated for each shift condition. Planning target volume (PTV) coverage and PTV maximum dose (Dmax) were then compared. The dosimetric effects of BLS on the targets and organs at risk (OARs) under non-rigid anatomic changes were also evaluated using a clinical dataset based on magnetic resonance imaging acquired during treatment.

Results

In the simulation analysis of superior–inferior shifts, target coverage using BLS was comparable to that using ATS and ATP across all disease sites and improved compared with that using the uncorrected plan. For posterior shifts, target coverage remained comparable to that using ATS and ATP; however, BLS increased the PTV Dmax at all posterior shift magnitudes (1–10 mm) in prostate and pancreatic cases, with limited increases in liver cases. In the clinical dataset, OAR doses upon left–right or anterior–posterior displacement were greater using BLS than using ATP, ATS, and uncorrected plans in the prostate and pancreatic cases, with limited increases in the liver cases.

Conclusions

The dosimetric impact of BLS relies on motion direction and plan characteristics. BLS was stable for superior–inferior shifts, whereas posterior shifts may increase PTV hotspots and OAR doses. Therefore, clinical application of BLS should consider motion direction and plan design rather than applying a uniform strategy.

基于目标运动和计划特性的基线移位计划在磁共振直线加速器中的剂量学影响
本研究研究了基线位移(BLS)在磁共振直线加速器中的剂量学效应,并将其与自适应位置(ATP)、自适应形状(ATS)和不自适应的未校正计划进行了比较。方法在30例患者(10例前列腺、10例肝脏、10例胰腺)的模拟数据集中,所有结构分别在上下方向和后方向刚性移位1、3、5和10 mm,并针对每种移位条件生成4种方案(ATS再优化、ATP再优化、使用分段孔径变形算法的BLS和不适应的未校正方案)。然后比较计划靶体积(PTV)覆盖率和PTV最大剂量(Dmax)。使用基于治疗期间获得的磁共振成像的临床数据集,还评估了BLS对非刚性解剖改变下靶和危险器官(OARs)的剂量学效应。结果在优-劣移位的模拟分析中,在所有疾病部位,使用BLS的目标覆盖率与使用ATS和ATP的目标覆盖率相当,并且与使用未校正计划的目标覆盖率相比有所提高。对于后验偏移,目标覆盖范围与ATS和ATP相当;然而,在前列腺和胰腺病例中,BLS增加了所有后移幅度(1-10 mm)的PTV Dmax,在肝脏病例中增加有限。在临床数据集中,在前列腺和胰腺病例中,使用BLS进行左右或前后移位时的OAR剂量大于使用ATP、ATS和未校正方案,肝脏病例的OAR剂量增加有限。结论BLS对剂量学的影响取决于运动方向和计划特征。BLS在上下移位时是稳定的,而后移位可能增加PTV热点和OAR剂量。因此,临床应用BLS应考虑运动方向和计划设计,而不是采用统一的策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
19.00%
发文量
331
审稿时长
3 months
期刊介绍: Journal of Applied Clinical Medical Physics is an international Open Access publication dedicated to clinical medical physics. JACMP welcomes original contributions dealing with all aspects of medical physics from scientists working in the clinical medical physics around the world. JACMP accepts only online submission. JACMP will publish: -Original Contributions: Peer-reviewed, investigations that represent new and significant contributions to the field. Recommended word count: up to 7500. -Review Articles: Reviews of major areas or sub-areas in the field of clinical medical physics. These articles may be of any length and are peer reviewed. -Technical Notes: These should be no longer than 3000 words, including key references. -Letters to the Editor: Comments on papers published in JACMP or on any other matters of interest to clinical medical physics. These should not be more than 1250 (including the literature) and their publication is only based on the decision of the editor, who occasionally asks experts on the merit of the contents. -Book Reviews: The editorial office solicits Book Reviews. -Announcements of Forthcoming Meetings: The Editor may provide notice of forthcoming meetings, course offerings, and other events relevant to clinical medical physics. -Parallel Opposed Editorial: We welcome topics relevant to clinical practice and medical physics profession. The contents can be controversial debate or opposed aspects of an issue. One author argues for the position and the other against. Each side of the debate contains an opening statement up to 800 words, followed by a rebuttal up to 500 words. Readers interested in participating in this series should contact the moderator with a proposed title and a short description of the topic
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书