Andreas Havsgård Handeland, Hardev Singh Grewal, Camilla Grindeland Boer, Daniel J. Indelicato, Kristian Smeland Ytre-Hauge, Helge Henjum, Camilla Hanquist Stokkevåg
{"title":"Dynamic Proton arc therapy for paediatric parameningeal rhabdomyosarcoma","authors":"Andreas Havsgård Handeland, Hardev Singh Grewal, Camilla Grindeland Boer, Daniel J. Indelicato, Kristian Smeland Ytre-Hauge, Helge Henjum, Camilla Hanquist Stokkevåg","doi":"10.1002/acm2.70867","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Parameningeal rhabdomyosarcomas (PM-RMS) are pediatric tumors with a high risk of local failure and severe toxicity. Intensity modulated proton therapy (IMPT) offers improved healthy tissue sparing compared to conventional photon-based radiotherapy, and proton arc therapy (PAT) might offer further improvement in healthy tissue sparing for these patients, thus emphasizing the need for systematic studies specifically focusing on PM-RMS patients. Additionally, the relative biological effectiveness (RBE) of protons is known to vary with linear energy transfer (LET).</p>\n </section>\n \n <section>\n \n <h3> Purpose</h3>\n \n <p>The aim of this study was to investigate the potential of LET-optimized PAT for PM-RMS treatment.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Volumetric modulated arc therapy (VMAT) plans, IMPT and PAT plans, both with and without LET optimization were made for 13 PM-RMS patients using Raystation version 2023B. The plans were evaluated based on the achievement of clinical goals, homogeneity index, delivery time, robustness, LET and variable RBE-weighted dose within the target and selected OARs.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>LET optimization increased the mean LET in the target from 2.5 keV/µm [2.1, 2.8] to 3.4 keV/µm [2.7, 4.1] for IMPT and from 2.8 keV/µm [2.5, 3.1] to 3.4 keV/µm [2.7, 4.0] for PAT with minor changes in dose distributions. Target coverage and OAR doses were comparable between IMPT and PAT, while both had an expected improvement in OAR sparing compared to VMAT. Delivery times were 134.5 [95.3, 203.7] seconds for the IMPT plans and 197.4 [138.9, 244.6] seconds for the PAT plans before LET optimization, and were for both modalities reduced by around 2–5 seconds after LET optimization.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The dose distribution was similar across PAT and IMPT in this study, and superior compared to VMAT. LET optimization in the proton plans achieved LET improvements in both target and OARs without compromising dose.</p>\n </section>\n </div>","PeriodicalId":14989,"journal":{"name":"Journal of Applied Clinical Medical Physics","volume":"27 11","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2026-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/acm2.70867","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Clinical Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/acm2.70867","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Parameningeal rhabdomyosarcomas (PM-RMS) are pediatric tumors with a high risk of local failure and severe toxicity. Intensity modulated proton therapy (IMPT) offers improved healthy tissue sparing compared to conventional photon-based radiotherapy, and proton arc therapy (PAT) might offer further improvement in healthy tissue sparing for these patients, thus emphasizing the need for systematic studies specifically focusing on PM-RMS patients. Additionally, the relative biological effectiveness (RBE) of protons is known to vary with linear energy transfer (LET).
Purpose
The aim of this study was to investigate the potential of LET-optimized PAT for PM-RMS treatment.
Methods
Volumetric modulated arc therapy (VMAT) plans, IMPT and PAT plans, both with and without LET optimization were made for 13 PM-RMS patients using Raystation version 2023B. The plans were evaluated based on the achievement of clinical goals, homogeneity index, delivery time, robustness, LET and variable RBE-weighted dose within the target and selected OARs.
Results
LET optimization increased the mean LET in the target from 2.5 keV/µm [2.1, 2.8] to 3.4 keV/µm [2.7, 4.1] for IMPT and from 2.8 keV/µm [2.5, 3.1] to 3.4 keV/µm [2.7, 4.0] for PAT with minor changes in dose distributions. Target coverage and OAR doses were comparable between IMPT and PAT, while both had an expected improvement in OAR sparing compared to VMAT. Delivery times were 134.5 [95.3, 203.7] seconds for the IMPT plans and 197.4 [138.9, 244.6] seconds for the PAT plans before LET optimization, and were for both modalities reduced by around 2–5 seconds after LET optimization.
Conclusions
The dose distribution was similar across PAT and IMPT in this study, and superior compared to VMAT. LET optimization in the proton plans achieved LET improvements in both target and OARs without compromising dose.
期刊介绍:
Journal of Applied Clinical Medical Physics is an international Open Access publication dedicated to clinical medical physics. JACMP welcomes original contributions dealing with all aspects of medical physics from scientists working in the clinical medical physics around the world. JACMP accepts only online submission.
JACMP will publish:
-Original Contributions: Peer-reviewed, investigations that represent new and significant contributions to the field. Recommended word count: up to 7500.
-Review Articles: Reviews of major areas or sub-areas in the field of clinical medical physics. These articles may be of any length and are peer reviewed.
-Technical Notes: These should be no longer than 3000 words, including key references.
-Letters to the Editor: Comments on papers published in JACMP or on any other matters of interest to clinical medical physics. These should not be more than 1250 (including the literature) and their publication is only based on the decision of the editor, who occasionally asks experts on the merit of the contents.
-Book Reviews: The editorial office solicits Book Reviews.
-Announcements of Forthcoming Meetings: The Editor may provide notice of forthcoming meetings, course offerings, and other events relevant to clinical medical physics.
-Parallel Opposed Editorial: We welcome topics relevant to clinical practice and medical physics profession. The contents can be controversial debate or opposed aspects of an issue. One author argues for the position and the other against. Each side of the debate contains an opening statement up to 800 words, followed by a rebuttal up to 500 words. Readers interested in participating in this series should contact the moderator with a proposed title and a short description of the topic