Estimating Residual Kidney Function in Hemodialysis Patients Using Serum Uromodulin.

David A Jaques, Valérie Jotterand Drepper, Nicola Marangon, Olivier Devuyst, Sophie De Seigneux, Patrick Saudan, Belen Ponte
{"title":"Estimating Residual Kidney Function in Hemodialysis Patients Using Serum Uromodulin.","authors":"David A Jaques, Valérie Jotterand Drepper, Nicola Marangon, Olivier Devuyst, Sophie De Seigneux, Patrick Saudan, Belen Ponte","doi":"10.2215/CJN.0000001247","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Residual kidney function (RKF) monitoring is essential to safe incremental hemodialysis (HD) prescription. Yet the cumbersome nature of interdialytic urine collections represents a major barrier to routine implementation. We investigated serum uromodulin, as a marker of functional renal mass, in identifying HD patients with clinically significant RKF when used alone, or in combination with serum β2-microglobulin, a traditional marker of glomerular filtration.</p><p><strong>Methods: </strong>We conducted a prospective observational study of 151 HD patients at two centers in Geneva, Switzerland. Serum uromodulin and β2-microglobulin were measured on pre-dialysis samples, and residual urea clearance (KRU) was determined by interdialytic timed urine collection. The discriminative performance of each biomarker for identifying patients with KRU ≥2 mL/min/35L was assessed by receiver operating characteristic (ROC) analysis, and the two markers were then combined using logistic regression. We applied a two-threshold grey-zone strategy, defining a priori rule-out and rule-in cutoffs to achieve ≥90% sensitivity and specificity, respectively.</p><p><strong>Results: </strong>Of the 151 patients, 92 (61%) had KRU <2 mL/min/35L and 59 (39%) had KRU ≥2 mL/min/35L. Serum uromodulin discriminated KRU ≥2 mL/min/35L with an area under the curve (AUC) of 0.891 (95% CI 0.839-0.944), statistically equivalent to β2-microglobulin (AUC 0.877; P=0.66). Each marker contributed independent information: the combined model achieved an AUC of 0.923 (95% CI 0.883-0.964), superior to either alone (vs uromodulin P=0.03; vs β2-microglobulin P=0.01). Using the grey-zone strategy, uromodulin alone classified 76% of patients without urine collection (negative predictive value (NPV) 97%, positive predictive value (PPV) 84%), while the combined model classified 85%. Restricting analysis to non-anuric patients modestly decreased discrimination (AUC 0.833) with preserved PPV (84%), while avoiding the need for urine collection in 80% of this sub-group.</p><p><strong>Conclusions: </strong>Serum uromodulin provides RKF information orthogonal to and non-redundant with conventional filtration markers. Their combination reliably identifies the KRU ≥2 mL/min/35L threshold relevant to incremental hemodialysis, sparing most patients from urine collection.</p>","PeriodicalId":520592,"journal":{"name":"Clinical journal of the American Society of Nephrology : CJASN","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical journal of the American Society of Nephrology : CJASN","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2215/CJN.0000001247","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Residual kidney function (RKF) monitoring is essential to safe incremental hemodialysis (HD) prescription. Yet the cumbersome nature of interdialytic urine collections represents a major barrier to routine implementation. We investigated serum uromodulin, as a marker of functional renal mass, in identifying HD patients with clinically significant RKF when used alone, or in combination with serum β2-microglobulin, a traditional marker of glomerular filtration.

Methods: We conducted a prospective observational study of 151 HD patients at two centers in Geneva, Switzerland. Serum uromodulin and β2-microglobulin were measured on pre-dialysis samples, and residual urea clearance (KRU) was determined by interdialytic timed urine collection. The discriminative performance of each biomarker for identifying patients with KRU ≥2 mL/min/35L was assessed by receiver operating characteristic (ROC) analysis, and the two markers were then combined using logistic regression. We applied a two-threshold grey-zone strategy, defining a priori rule-out and rule-in cutoffs to achieve ≥90% sensitivity and specificity, respectively.

Results: Of the 151 patients, 92 (61%) had KRU <2 mL/min/35L and 59 (39%) had KRU ≥2 mL/min/35L. Serum uromodulin discriminated KRU ≥2 mL/min/35L with an area under the curve (AUC) of 0.891 (95% CI 0.839-0.944), statistically equivalent to β2-microglobulin (AUC 0.877; P=0.66). Each marker contributed independent information: the combined model achieved an AUC of 0.923 (95% CI 0.883-0.964), superior to either alone (vs uromodulin P=0.03; vs β2-microglobulin P=0.01). Using the grey-zone strategy, uromodulin alone classified 76% of patients without urine collection (negative predictive value (NPV) 97%, positive predictive value (PPV) 84%), while the combined model classified 85%. Restricting analysis to non-anuric patients modestly decreased discrimination (AUC 0.833) with preserved PPV (84%), while avoiding the need for urine collection in 80% of this sub-group.

Conclusions: Serum uromodulin provides RKF information orthogonal to and non-redundant with conventional filtration markers. Their combination reliably identifies the KRU ≥2 mL/min/35L threshold relevant to incremental hemodialysis, sparing most patients from urine collection.

用血清尿调素估计血透患者的残余肾功能。
背景:残余肾功能(RKF)监测是安全增量血液透析(HD)处方的必要条件。然而,透析间期尿液收集的繁琐性质是常规实施的主要障碍。我们研究了血清尿调蛋白作为功能性肾肿块的标志物,在单独使用或与血清β2-微球蛋白(肾小球滤过的传统标志物)联合使用时,在鉴别患有临床显著RKF的HD患者中的作用。方法:我们在瑞士日内瓦的两个中心对151例HD患者进行了前瞻性观察研究。透析前测定血清尿调素和β2-微球蛋白,透析间期定时收集尿液测定剩余尿素清除率(KRU)。采用受试者工作特征(ROC)分析评估各生物标志物对KRU≥2 mL/min/35L患者的鉴别性能,然后采用logistic回归将两种标志物组合。我们采用双阈值灰色地带策略,定义先验排除和规则截止,分别达到≥90%的灵敏度和特异性。结果:151例患者中,92例(61%)发生KRU。结论:血清尿调蛋白提供的RKF信息与常规过滤标志物正交且无冗余。它们的组合可靠地识别了与渐进式血液透析相关的KRU≥2ml /min/35L阈值,使大多数患者免于尿液收集。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书