Vânia Fernandes, João Vasconcelos, José Vidoedo, Miguel Maia, João Almeida Pinto
{"title":"PERCUTANEOUS MECHANICAL THROMBECTOMY: A NEW TOOL IN THE TREATMENT OF ACUTE MESENTERIC ISCHEMIA.","authors":"Vânia Fernandes, João Vasconcelos, José Vidoedo, Miguel Maia, João Almeida Pinto","doi":"10.48729/pjctvs.659","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The diagnosis of acute mesenteric ischemia (AMI) remains challenging due to nonspecific symptoms and signs that lead to a high mortality rate. Common causes include cardiac emboli and thrombosis of a mesenteric plaque.</p><p><strong>Objective: </strong>To present a clinical case of acute mesenteric ischemia that underwent successful endovascular revascularization.</p><p><strong>Case report: </strong>82-year-old female patient with a history of atrioventricular block, hypertension, and dementia. She was admitted to the emergency department for acute abdominal pain with onset 3 days before. Diagnosis of ischemic colitis secondary to acute superior mesenteric artery occlusion was confirmed by angioCT scan. Endovascular treatment was performed: percutaneous mechanical thrombectomy through left brachial access using the Rotarex® system (Straub Medical). She improved from her previous symptoms and was discharged at day 6, with no need of exploratory laparotomy.</p><p><strong>Discussion/conclusion: </strong>AMI is a vascular emergency that requires rapid identification and treatment. There are two courses of action for mesenteric revascularization: open or endovascular. Some authors have demonstrated an advantage in the endovascular approach, with reduced morbidity and mortality, especially in an often aging and frail group of patients. The Rotarex® (Straub Medical) system fragments the thrombus and aspirates it at the same time, thus avoiding embolic phenomena at distance. Despite being a new technology, it has shown to be a very promising tool for AMI treatment due to its fast restoration of blood flow with minimal invasiveness.</p>","PeriodicalId":74480,"journal":{"name":"Portuguese journal of cardiac thoracic and vascular surgery","volume":"28 3","pages":"67-70"},"PeriodicalIF":0.0000,"publicationDate":"2026-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Portuguese journal of cardiac thoracic and vascular surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.48729/pjctvs.659","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: The diagnosis of acute mesenteric ischemia (AMI) remains challenging due to nonspecific symptoms and signs that lead to a high mortality rate. Common causes include cardiac emboli and thrombosis of a mesenteric plaque.
Objective: To present a clinical case of acute mesenteric ischemia that underwent successful endovascular revascularization.
Case report: 82-year-old female patient with a history of atrioventricular block, hypertension, and dementia. She was admitted to the emergency department for acute abdominal pain with onset 3 days before. Diagnosis of ischemic colitis secondary to acute superior mesenteric artery occlusion was confirmed by angioCT scan. Endovascular treatment was performed: percutaneous mechanical thrombectomy through left brachial access using the Rotarex® system (Straub Medical). She improved from her previous symptoms and was discharged at day 6, with no need of exploratory laparotomy.
Discussion/conclusion: AMI is a vascular emergency that requires rapid identification and treatment. There are two courses of action for mesenteric revascularization: open or endovascular. Some authors have demonstrated an advantage in the endovascular approach, with reduced morbidity and mortality, especially in an often aging and frail group of patients. The Rotarex® (Straub Medical) system fragments the thrombus and aspirates it at the same time, thus avoiding embolic phenomena at distance. Despite being a new technology, it has shown to be a very promising tool for AMI treatment due to its fast restoration of blood flow with minimal invasiveness.