Convolutional neural network metal artifact reduction in ultra-high resolution photon counting detector CT of middle- and inner-ear implants

IF 3.2 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Medical physics Pub Date : 2026-10-14 DOI:10.1002/mp.70711
Kevin J. Treb, Maryam Sadeghian, Wenchao Cao, Paul J. Farnsworth, John I. Lane, John C. Benson, Christopher P. Favazza, Andrea Ferrero, Andrew D. Missert, Matthew L. Carlson, Shuai Leng
{"title":"Convolutional neural network metal artifact reduction in ultra-high resolution photon counting detector CT of middle- and inner-ear implants","authors":"Kevin J. Treb,&nbsp;Maryam Sadeghian,&nbsp;Wenchao Cao,&nbsp;Paul J. Farnsworth,&nbsp;John I. Lane,&nbsp;John C. Benson,&nbsp;Christopher P. Favazza,&nbsp;Andrea Ferrero,&nbsp;Andrew D. Missert,&nbsp;Matthew L. Carlson,&nbsp;Shuai Leng","doi":"10.1002/mp.70711","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Metallic inner- and middle-ear implants with submillimeter structures requiring ultra-high resolution (UHR) imaging invariably result in metal artifacts at CT, which can obscure adjacent microstructures and subtle pathologic findings. Current metal artifact reduction techniques can be less effective for small metal objects or metal in heterogeneous background anatomy, and can sometimes introduce new artifacts or noise.</p>\n </section>\n \n <section>\n \n <h3> Purpose</h3>\n \n <p>To develop and evaluate an image-domain convolutional neural network to reduce metal artifacts near inner- and middle-ear implants in UHR photon-counting-detector (PCD)-CT.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>For network training, three stapes prosthesis models containing titanium and platinum were randomly oriented within a head-sized phantom and imaged on a PCD-CT with a UHR protocol. Metal and metal+artifact images were isolated by subtraction of the phantom background followed by CT number thresholding. Isolated artifact signal was enhanced via multiplication with a randomized factor ranging from one to a pre-determined artifact amplification scalar hyperparameter. Paired training inputs (with artifacts) and labels (without artifacts) were created by adding metal-free patient temporal bone images with metal+artifact and metal images, respectively. Combinations of 9 patient CT volumes and 24 metal CT volumes were used to create 216 CT volumes for training and validation with an 80%/20% training/validation split. The network was retrained with different amplification scalars (5, 10, 20, 30, 40) and with either mean-squared-error or mean-absolute-error loss functions to determine the optimal combination of these hyperparameters. The network was tested on 7 CT volumes from patients with three different implant types: stapes prostheses, cochlear implants, and a transverse sinus stent. Network performance was quantified through the artifact index, noise magnitude, CT number preservation of metal and bone, and dimensions of metal measured as the full-width at half-maximum of CT number line profiles.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Networks trained with mean-squared-error demonstrated a trade-off between metal artifact reduction and preservation of bone CT number as the artifact amplification scalar changed. The trade-off was not observed when mean-absolute error was used. Using the network with hyperparameters that best preserved bone and reduced artifacts simultaneously (mean-absolute-error, amplification scalar 20), the artifact index was improved by 83.2% (<i>p </i>&lt; 0.001) across all implant types, and image noise was reduced by 46.8% (<i>p </i>&lt; 0.001). Artifact reduction was significantly better for cases with stapes prostheses than the other implant types (<i>p </i>&lt; 0.004), although artifact index was still greatly improved for all implant types (91.1% for the stapes prostheses, 81.3% for the CI, and 72.9% for the transverse sinus stent). Metal implant dimensions were not significantly different between the network input and output images (<i>p</i> = 0.67).</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>An image-domain convolutional neural network with task-specific hyperparameters reduced artifact severity and image noise in UHR PCD-CT of different inner- and middle-ear implants without loss of fine image detail.</p>\n </section>\n </div>","PeriodicalId":18384,"journal":{"name":"Medical physics","volume":"53 10","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2026-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical physics","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/mp.70711","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Metallic inner- and middle-ear implants with submillimeter structures requiring ultra-high resolution (UHR) imaging invariably result in metal artifacts at CT, which can obscure adjacent microstructures and subtle pathologic findings. Current metal artifact reduction techniques can be less effective for small metal objects or metal in heterogeneous background anatomy, and can sometimes introduce new artifacts or noise.

Purpose

To develop and evaluate an image-domain convolutional neural network to reduce metal artifacts near inner- and middle-ear implants in UHR photon-counting-detector (PCD)-CT.

Methods

For network training, three stapes prosthesis models containing titanium and platinum were randomly oriented within a head-sized phantom and imaged on a PCD-CT with a UHR protocol. Metal and metal+artifact images were isolated by subtraction of the phantom background followed by CT number thresholding. Isolated artifact signal was enhanced via multiplication with a randomized factor ranging from one to a pre-determined artifact amplification scalar hyperparameter. Paired training inputs (with artifacts) and labels (without artifacts) were created by adding metal-free patient temporal bone images with metal+artifact and metal images, respectively. Combinations of 9 patient CT volumes and 24 metal CT volumes were used to create 216 CT volumes for training and validation with an 80%/20% training/validation split. The network was retrained with different amplification scalars (5, 10, 20, 30, 40) and with either mean-squared-error or mean-absolute-error loss functions to determine the optimal combination of these hyperparameters. The network was tested on 7 CT volumes from patients with three different implant types: stapes prostheses, cochlear implants, and a transverse sinus stent. Network performance was quantified through the artifact index, noise magnitude, CT number preservation of metal and bone, and dimensions of metal measured as the full-width at half-maximum of CT number line profiles.

Results

Networks trained with mean-squared-error demonstrated a trade-off between metal artifact reduction and preservation of bone CT number as the artifact amplification scalar changed. The trade-off was not observed when mean-absolute error was used. Using the network with hyperparameters that best preserved bone and reduced artifacts simultaneously (mean-absolute-error, amplification scalar 20), the artifact index was improved by 83.2% (p < 0.001) across all implant types, and image noise was reduced by 46.8% (p < 0.001). Artifact reduction was significantly better for cases with stapes prostheses than the other implant types (p < 0.004), although artifact index was still greatly improved for all implant types (91.1% for the stapes prostheses, 81.3% for the CI, and 72.9% for the transverse sinus stent). Metal implant dimensions were not significantly different between the network input and output images (p = 0.67).

Conclusion

An image-domain convolutional neural network with task-specific hyperparameters reduced artifact severity and image noise in UHR PCD-CT of different inner- and middle-ear implants without loss of fine image detail.

卷积神经网络在中耳和内耳植入物超高分辨率光子计数检测器CT中的金属伪影降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical physics
Medical physics 医学-核医学
CiteScore
6.80
自引率
15.80%
发文量
660
审稿时长
1.7 months
期刊介绍: Medical Physics publishes original, high impact physics, imaging science, and engineering research that advances patient diagnosis and therapy through contributions in 1) Basic science developments with high potential for clinical translation 2) Clinical applications of cutting edge engineering and physics innovations 3) Broadly applicable and innovative clinical physics developments Medical Physics is a journal of global scope and reach. By publishing in Medical Physics your research will reach an international, multidisciplinary audience including practicing medical physicists as well as physics- and engineering based translational scientists. We work closely with authors of promising articles to improve their quality.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书