Santiago Vildoza, Victor Chen, Stone Sima, Tobias Buzzai Wilson, David Edis
{"title":"An anatomically contoured interbody cage is associated with reduced subsidence after oblique lumbar interbody fusion: a comparative cohort study.","authors":"Santiago Vildoza, Victor Chen, Stone Sima, Tobias Buzzai Wilson, David Edis","doi":"10.1080/17434440.2026.2748185","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study compared subsidence and segmental lordosis correction between a novel anatomically contoured cage and a conventional wedge-shaped cage used for oblique lumbar interbody fusion (OLIF).</p><p><strong>Research design and methods: </strong>This retrospective cohort included 38 patients undergoing OLIF at 60 levels with bilateral pedicle screw fixation. Subsidence was defined as ≥2 mm endplate penetration assessed on six-month computed tomography. Generalized estimating equations accounted for within-patient clustering and adjusted for minimum Hounsfield units, with additional adjustment for age or operated level in separate models.</p><p><strong>Results: </strong>Subsidence occurred at 2/30 levels (6.7%) treated with the anatomically contoured cage and 10/30 (33.3%) treated with the conventional cage (<i>p</i> = 0.021). The conventional cage was associated with higher odds of subsidence in the primary model (odds ratio [OR] 5.45; 95% confidence interval [CI] 1.35-22.00; <i>p</i> = 0.017). This association remained significant after age adjustment (OR 4.68; 95% CI 1.02-21.46; <i>p</i> = 0.047), but not after operated-level adjustment (OR 4.44; 95% CI 0.80-24.68; <i>p</i> = 0.088). Subsidence was associated with less lordosis gain (adjusted difference -3.33°; 95% CI - 5.03 to -1.62; <i>p</i> < 0.001).</p><p><strong>Conclusions: </strong>The anatomically contoured cage was associated with lower subsidence, but this association was sensitive to operated-level adjustment. The small sample and non-randomized design warrant cautious interpretation and prospective confirmation.</p>","PeriodicalId":94006,"journal":{"name":"Expert review of medical devices","volume":" ","pages":"1-9"},"PeriodicalIF":2.7000,"publicationDate":"2026-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert review of medical devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17434440.2026.2748185","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: This study compared subsidence and segmental lordosis correction between a novel anatomically contoured cage and a conventional wedge-shaped cage used for oblique lumbar interbody fusion (OLIF).
Research design and methods: This retrospective cohort included 38 patients undergoing OLIF at 60 levels with bilateral pedicle screw fixation. Subsidence was defined as ≥2 mm endplate penetration assessed on six-month computed tomography. Generalized estimating equations accounted for within-patient clustering and adjusted for minimum Hounsfield units, with additional adjustment for age or operated level in separate models.
Results: Subsidence occurred at 2/30 levels (6.7%) treated with the anatomically contoured cage and 10/30 (33.3%) treated with the conventional cage (p = 0.021). The conventional cage was associated with higher odds of subsidence in the primary model (odds ratio [OR] 5.45; 95% confidence interval [CI] 1.35-22.00; p = 0.017). This association remained significant after age adjustment (OR 4.68; 95% CI 1.02-21.46; p = 0.047), but not after operated-level adjustment (OR 4.44; 95% CI 0.80-24.68; p = 0.088). Subsidence was associated with less lordosis gain (adjusted difference -3.33°; 95% CI - 5.03 to -1.62; p < 0.001).
Conclusions: The anatomically contoured cage was associated with lower subsidence, but this association was sensitive to operated-level adjustment. The small sample and non-randomized design warrant cautious interpretation and prospective confirmation.