{"title":"Presubmission Pathologic Quality Control for FoundationOne CDx Comprehensive Genomic Profiling.","authors":"Yume Natori, Yosuke Hirotsu, Masahiro Shibusawa, Kaito Nakamura, Shunsuke Watanabe, Saki Amemiya, Yuki Nagakubo, Ryosuke Tajiri, Toshio Oyama, Hitoshi Mochizuki, Masao Omata","doi":"10.1016/j.jmoldx.2026.09.002","DOIUrl":null,"url":null,"abstract":"<p><p>Comprehensive genomic profiling using FoundationOne CDx (F1CDx) requires formalin-fixed, paraffin-embedded specimens with sufficient tumor area and DNA yield. Presubmission pathologic assessment is critical but has not been systematically evaluated in real-world practice. This study analyzed 371 consecutive F1CDx requests at a cancer genomic medicine designated hospital in Japan. Presubmission quality checks assessed tumor surface area and estimated section numbers and residual specimen volume. Assay outcomes were classified as presubmission cancellation, temporary suspension (insufficient DNA, suspected contamination, or technical issues), qualified, or pass. Of 371 requests, 52 (14.0%) were cancelled before submission, mainly because of insufficient specimen volume or clinical decision. Among 319 submitted cases, 22 (6.9%) were temporarily suspended. Among 297 cases with returned results, 256 (86.2%) achieved pass quality and 41 (13.8%) were qualified. Tumor content-related parameters, including institutional tumor content, laboratory-assessed tumor content, and sequencing-estimated tumor content, were all significantly lower in qualified than in pass cases. In qualified cases, evaluation of tumor mutational burden and microsatellite instability was successful in only 31.7% and 19.5%, respectively. In multivariable analysis, lower tumor content was the only independent predictor of quality control failure. These findings indicate most F1CDx assay failures are attributable to insufficient tumor content or specimen volume. Strengthened presubmission quality control and coordinated workflows can meaningfully improve comprehensive genomic profiling success. Limitations include the retrospective single-institution design and lack of external validation.</p>","PeriodicalId":50128,"journal":{"name":"Journal of Molecular Diagnostics","volume":" ","pages":""},"PeriodicalIF":3.9000,"publicationDate":"2026-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Molecular Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jmoldx.2026.09.002","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PATHOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Comprehensive genomic profiling using FoundationOne CDx (F1CDx) requires formalin-fixed, paraffin-embedded specimens with sufficient tumor area and DNA yield. Presubmission pathologic assessment is critical but has not been systematically evaluated in real-world practice. This study analyzed 371 consecutive F1CDx requests at a cancer genomic medicine designated hospital in Japan. Presubmission quality checks assessed tumor surface area and estimated section numbers and residual specimen volume. Assay outcomes were classified as presubmission cancellation, temporary suspension (insufficient DNA, suspected contamination, or technical issues), qualified, or pass. Of 371 requests, 52 (14.0%) were cancelled before submission, mainly because of insufficient specimen volume or clinical decision. Among 319 submitted cases, 22 (6.9%) were temporarily suspended. Among 297 cases with returned results, 256 (86.2%) achieved pass quality and 41 (13.8%) were qualified. Tumor content-related parameters, including institutional tumor content, laboratory-assessed tumor content, and sequencing-estimated tumor content, were all significantly lower in qualified than in pass cases. In qualified cases, evaluation of tumor mutational burden and microsatellite instability was successful in only 31.7% and 19.5%, respectively. In multivariable analysis, lower tumor content was the only independent predictor of quality control failure. These findings indicate most F1CDx assay failures are attributable to insufficient tumor content or specimen volume. Strengthened presubmission quality control and coordinated workflows can meaningfully improve comprehensive genomic profiling success. Limitations include the retrospective single-institution design and lack of external validation.
期刊介绍:
The Journal of Molecular Diagnostics, the official publication of the Association for Molecular Pathology (AMP), co-owned by the American Society for Investigative Pathology (ASIP), seeks to publish high quality original papers on scientific advances in the translation and validation of molecular discoveries in medicine into the clinical diagnostic setting, and the description and application of technological advances in the field of molecular diagnostic medicine. The editors welcome for review articles that contain: novel discoveries or clinicopathologic correlations including studies in oncology, infectious diseases, inherited diseases, predisposition to disease, clinical informatics, or the description of polymorphisms linked to disease states or normal variations; the application of diagnostic methodologies in clinical trials; or the development of new or improved molecular methods which may be applied to diagnosis or monitoring of disease or disease predisposition.