Short-frame, self-expanding, fully recapturable transcatheter aortic valve replacement device in pure aortic regurgitation: Procedural performance and 30-day outcomes.

IF 2.3 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Hui Yan, Yunyao Li, Weiguo Wan, Haihan Liao, Sheng Cao, Hongning Song, Xiaoya Zhou, Hong Jiang, Bing Huang
{"title":"Short-frame, self-expanding, fully recapturable transcatheter aortic valve replacement device in pure aortic regurgitation: Procedural performance and 30-day outcomes.","authors":"Hui Yan, Yunyao Li, Weiguo Wan, Haihan Liao, Sheng Cao, Hongning Song, Xiaoya Zhou, Hong Jiang, Bing Huang","doi":"10.1016/j.carrev.2026.10.006","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Achieving stable anchoring and effective sealing remains the principal limitation of transcatheter aortic valve replacement (TAVR) in patients with pure native aortic regurgitation (PNAR). A short-frame, fully recapturable self-expanding valve may expand the procedural margin by enabling iterative repositioning and implantation depth optimisation in non-calcified anatomy.</p><p><strong>Methods: </strong>We analysed 13 consecutive patients with symptomatic moderate-to-severe or severe PNAR who underwent transfemoral TAVR with the ScienCrown® (Lepu Medical, Beijing, China) system. The primary endpoint was technical success at exit from the procedure room according to VARC-3 criteria. Secondary endpoints included device success and early safety at 30 days.</p><p><strong>Results: </strong>Technical success was achieved in all patients (13/13, 100%), and device success at 30 days was also achieved in all patients (13/13, 100%). The 30-day early safety endpoint was met in 12 patients (92.3%). The mean prosthesis size was 27.62 ± 1.26 mm, with a mean prosthesis diameter oversizing relative to the average annular diameter of 12.90 ± 3.54%; no balloon predilatation was performed. The mean number of deployment attempts was 1.62 ± 0.77. All procedures were completed without valve embolisation/migration, coronary obstruction, second-valve implantation, or emergency surgery. One patient (7.69%) developed complete atrioventricular block on postoperative day 3 and underwent permanent pacemaker implantation; no additional pacemaker implantations occurred through 30 days. Predischarge diffusion-weighted magnetic resonance imaging demonstrated no new acute cerebral infarction. At 30 days, there were no deaths, strokes or transient ischaemic attacks, myocardial infarction, life-threatening/major bleeding, major vascular complications, endocarditis, or valve-related reinterventions. Mean transvalvular gradients were 7.67 ± 5.20 mmHg, and all patients had improved or stable NYHA functional class with no moderate or severe residual aortic regurgitation.</p><p><strong>Conclusions: </strong>In this exploratory single-centre series, transfemoral TAVR using a short-frame, fully recapturable self-expanding valve achieved 100% technical success and favourable early safety and haemodynamic performance in selected patients with PNAR. Prospective multicentre studies with longer follow-up and appropriate comparator groups are warranted.</p>","PeriodicalId":47657,"journal":{"name":"Cardiovascular Revascularization Medicine","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2026-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Revascularization Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.carrev.2026.10.006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Achieving stable anchoring and effective sealing remains the principal limitation of transcatheter aortic valve replacement (TAVR) in patients with pure native aortic regurgitation (PNAR). A short-frame, fully recapturable self-expanding valve may expand the procedural margin by enabling iterative repositioning and implantation depth optimisation in non-calcified anatomy.

Methods: We analysed 13 consecutive patients with symptomatic moderate-to-severe or severe PNAR who underwent transfemoral TAVR with the ScienCrown® (Lepu Medical, Beijing, China) system. The primary endpoint was technical success at exit from the procedure room according to VARC-3 criteria. Secondary endpoints included device success and early safety at 30 days.

Results: Technical success was achieved in all patients (13/13, 100%), and device success at 30 days was also achieved in all patients (13/13, 100%). The 30-day early safety endpoint was met in 12 patients (92.3%). The mean prosthesis size was 27.62 ± 1.26 mm, with a mean prosthesis diameter oversizing relative to the average annular diameter of 12.90 ± 3.54%; no balloon predilatation was performed. The mean number of deployment attempts was 1.62 ± 0.77. All procedures were completed without valve embolisation/migration, coronary obstruction, second-valve implantation, or emergency surgery. One patient (7.69%) developed complete atrioventricular block on postoperative day 3 and underwent permanent pacemaker implantation; no additional pacemaker implantations occurred through 30 days. Predischarge diffusion-weighted magnetic resonance imaging demonstrated no new acute cerebral infarction. At 30 days, there were no deaths, strokes or transient ischaemic attacks, myocardial infarction, life-threatening/major bleeding, major vascular complications, endocarditis, or valve-related reinterventions. Mean transvalvular gradients were 7.67 ± 5.20 mmHg, and all patients had improved or stable NYHA functional class with no moderate or severe residual aortic regurgitation.

Conclusions: In this exploratory single-centre series, transfemoral TAVR using a short-frame, fully recapturable self-expanding valve achieved 100% technical success and favourable early safety and haemodynamic performance in selected patients with PNAR. Prospective multicentre studies with longer follow-up and appropriate comparator groups are warranted.

经导管主动脉瓣置换术治疗单纯主动脉反流的短框架、自膨胀、完全可恢复的装置:程序性能和30天预后。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Cardiovascular Revascularization Medicine
Cardiovascular Revascularization Medicine CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
3.30
自引率
5.90%
发文量
687
审稿时长
36 days
期刊介绍: Cardiovascular Revascularization Medicine (CRM) is an international and multidisciplinary journal that publishes original laboratory and clinical investigations related to revascularization therapies in cardiovascular medicine. Cardiovascular Revascularization Medicine publishes articles related to preclinical work and molecular interventions, including angiogenesis, cell therapy, pharmacological interventions, restenosis management, and prevention, including experiments conducted in human subjects, in laboratory animals, and in vitro. Specific areas of interest include percutaneous angioplasty in coronary and peripheral arteries, intervention in structural heart disease, cardiovascular surgery, etc.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书