Repurposing a commercial artificial intelligence vision platform for automated surgical instrument identification: a proof-of-concept study.

IF 3.3 Q1 SURGERY
Simon Stoerzer, Klinto Xhemo, Felix Gronau, Linda Feldbruegge, Philipp Felgendreff, Maximilian Kaltenecker, Jacques Hahn, Gerrit Grannas, Moritz Schmelzle
{"title":"Repurposing a commercial artificial intelligence vision platform for automated surgical instrument identification: a proof-of-concept study.","authors":"Simon Stoerzer, Klinto Xhemo, Felix Gronau, Linda Feldbruegge, Philipp Felgendreff, Maximilian Kaltenecker, Jacques Hahn, Gerrit Grannas, Moritz Schmelzle","doi":"10.1186/s13037-026-00512-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Retained surgical items are classified as never events but continue to occur, and the count meant to prevent them is often recorded as correct even when an item is retained. Computer vision could provide an independent check on what is on the instrument table, but purpose-built surgical systems are scarce. Industrial vision platforms offer a faster route, although their surgical performance is unknown.</p><p><strong>Methods: </strong>In a prospective experimental study, a commercial artificial intelligence vision platform developed for industrial inspection was applied to 19 surgical instruments and 3 suture items, each presented once in 100 runs (2,200 experiments). No software redesign was required, but the classifier had been trained on this item set, making this a supervised rather than a zero-shot setting. Two outcomes were recorded: whether the platform assigned the exact item identity, and whether it registered an item as present at the packing step irrespective of type, termed count-presence detection. Because experiments are clustered within items and runs, the primary estimate is the mean per-item accuracy with cluster-adjusted intervals.</p><p><strong>Results: </strong>The correct instruments were identified in 2,036 of 2,200 experiments (92.5%). The mean per-item accuracy was 92.5% (95% confidence interval 88.4 to 96.7; cluster-adjusted 87.7 to 95.6). Count-presence detection was 99.1% (98.7 to 99.4). Performance was reproducible across runs (intraclass correlation 0.02), whereas variance clustered by item (0.12). Accuracy ranged from 64% (suture needle 6-0) to 100% (six items). Errors were directional and almost always within visually near-identical sub-types.</p><p><strong>Conclusions: </strong>An industrial vision platform detected item presence with high reliability and identified item type with high accuracy, however, with a residual error rate of 7.5%. The errors were predictable and confined to visually similar classes, pointing to correctable mitigations rather than a fundamental limit. These figures represent an upper bound under highly controlled conditions rather than expected intraoperative performance. Such a system is intended to support rather than replace the perioperative team. This study establishes feasibility rather than clinical benefit; a prospective intraoperative study is the necessary next step.</p>","PeriodicalId":46782,"journal":{"name":"Patient Safety in Surgery","volume":"20 1","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2026-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13660092/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Patient Safety in Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13037-026-00512-z","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Retained surgical items are classified as never events but continue to occur, and the count meant to prevent them is often recorded as correct even when an item is retained. Computer vision could provide an independent check on what is on the instrument table, but purpose-built surgical systems are scarce. Industrial vision platforms offer a faster route, although their surgical performance is unknown.

Methods: In a prospective experimental study, a commercial artificial intelligence vision platform developed for industrial inspection was applied to 19 surgical instruments and 3 suture items, each presented once in 100 runs (2,200 experiments). No software redesign was required, but the classifier had been trained on this item set, making this a supervised rather than a zero-shot setting. Two outcomes were recorded: whether the platform assigned the exact item identity, and whether it registered an item as present at the packing step irrespective of type, termed count-presence detection. Because experiments are clustered within items and runs, the primary estimate is the mean per-item accuracy with cluster-adjusted intervals.

Results: The correct instruments were identified in 2,036 of 2,200 experiments (92.5%). The mean per-item accuracy was 92.5% (95% confidence interval 88.4 to 96.7; cluster-adjusted 87.7 to 95.6). Count-presence detection was 99.1% (98.7 to 99.4). Performance was reproducible across runs (intraclass correlation 0.02), whereas variance clustered by item (0.12). Accuracy ranged from 64% (suture needle 6-0) to 100% (six items). Errors were directional and almost always within visually near-identical sub-types.

Conclusions: An industrial vision platform detected item presence with high reliability and identified item type with high accuracy, however, with a residual error rate of 7.5%. The errors were predictable and confined to visually similar classes, pointing to correctable mitigations rather than a fundamental limit. These figures represent an upper bound under highly controlled conditions rather than expected intraoperative performance. Such a system is intended to support rather than replace the perioperative team. This study establishes feasibility rather than clinical benefit; a prospective intraoperative study is the necessary next step.

重新利用商业人工智能视觉平台进行自动手术器械识别:概念验证研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.80
自引率
8.10%
发文量
37
审稿时长
9 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书