Application of AI-assisted compressed sensing cine sequence in the assessment of cardiac function in children with Kawasaki disease.

IF 2 4区 医学 Q2 PEDIATRICS
Translational pediatrics Pub Date : 2026-09-30 Epub Date: 2026-08-31 DOI:10.21037/tp-2026-0641
Xin Zhao, Xihong Hu, Yipu Li, Quanli Shen, Yan Zheng, Chengxiang Lin, Kai Lu, Junpu Hu, Lan He, Chenxi Hu, Guanke Cai, Qiong Yao
{"title":"Application of AI-assisted compressed sensing cine sequence in the assessment of cardiac function in children with Kawasaki disease.","authors":"Xin Zhao, Xihong Hu, Yipu Li, Quanli Shen, Yan Zheng, Chengxiang Lin, Kai Lu, Junpu Hu, Lan He, Chenxi Hu, Guanke Cai, Qiong Yao","doi":"10.21037/tp-2026-0641","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cardiac magnetic resonance (CMR) imaging is an important tool for assessing the cardiac structure and function in Kawasaki disease. To perform a prospective analysis comparing the newly developed temporal artificial intelligence (AI)-assisted compressed sensing cine (ACS-cine) and conventional cine (Conv-cine) in the assessment of cardiac function in Kawasaki disease patients.</p><p><strong>Methods: </strong>This study included 45 patients (35 males), who were scanned using both ACS-cine and Conv-cine sequences. Left and right ventricular ejection fractions (LVEF and RVEF), left and right ventricular end-systolic volumes (LVESV and RVESV), and left and right ventricular end-diastolic volumes (LVEDV and RVEDV) were measured. The image quality and intraclass correlation coefficient (ICC) of the two methods were also assessed.</p><p><strong>Results: </strong>The mean acquisition time of ACS-cine was significantly shorter than that of Conv-cine (17.18±2.45 <i>vs.</i> 251.12±38.01 seconds, P<0.05). In terms of cardiac function measurements, the median LVEF measured by Conv-cine was higher than that of ACS-cine (63.0% <i>vs.</i> 61.0%, P<0.05), while median LVESV was lower in Conv-cine than in ACS-cine (26.5 <i>vs.</i> 27.9 mL/m<sup>2</sup>, P<0.05). The image quality score of ACS-cine was slightly higher than that of Conv-cine (4.41±0.50 <i>vs.</i> 3.87±0.65, P<0.001). The inter-observer consistency was almost perfect for both ACS-cine (ICC: 0.882-0.978) and Conv-cine (ICC: 0.952-0.991).</p><p><strong>Conclusions: </strong>ACS-cine technology demonstrates significant time efficiency advantages in CMR with satisfactory image quality, although there are statistically significant differences in the measurement of certain cardiac function parameters (LVEF and LVESV) compared to Conv-cine.</p>","PeriodicalId":23294,"journal":{"name":"Translational pediatrics","volume":"15 9","pages":"367"},"PeriodicalIF":2.0000,"publicationDate":"2026-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13655866/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Translational pediatrics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21037/tp-2026-0641","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/31 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Cardiac magnetic resonance (CMR) imaging is an important tool for assessing the cardiac structure and function in Kawasaki disease. To perform a prospective analysis comparing the newly developed temporal artificial intelligence (AI)-assisted compressed sensing cine (ACS-cine) and conventional cine (Conv-cine) in the assessment of cardiac function in Kawasaki disease patients.

Methods: This study included 45 patients (35 males), who were scanned using both ACS-cine and Conv-cine sequences. Left and right ventricular ejection fractions (LVEF and RVEF), left and right ventricular end-systolic volumes (LVESV and RVESV), and left and right ventricular end-diastolic volumes (LVEDV and RVEDV) were measured. The image quality and intraclass correlation coefficient (ICC) of the two methods were also assessed.

Results: The mean acquisition time of ACS-cine was significantly shorter than that of Conv-cine (17.18±2.45 vs. 251.12±38.01 seconds, P<0.05). In terms of cardiac function measurements, the median LVEF measured by Conv-cine was higher than that of ACS-cine (63.0% vs. 61.0%, P<0.05), while median LVESV was lower in Conv-cine than in ACS-cine (26.5 vs. 27.9 mL/m2, P<0.05). The image quality score of ACS-cine was slightly higher than that of Conv-cine (4.41±0.50 vs. 3.87±0.65, P<0.001). The inter-observer consistency was almost perfect for both ACS-cine (ICC: 0.882-0.978) and Conv-cine (ICC: 0.952-0.991).

Conclusions: ACS-cine technology demonstrates significant time efficiency advantages in CMR with satisfactory image quality, although there are statistically significant differences in the measurement of certain cardiac function parameters (LVEF and LVESV) compared to Conv-cine.

人工智能辅助压缩传感影像序列在川崎病患儿心功能评估中的应用
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Translational pediatrics
Translational pediatrics Medicine-Pediatrics, Perinatology and Child Health
CiteScore
4.50
自引率
5.00%
发文量
108
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书