{"title":"Progression of Tricuspid Regurgitation After Cardiac Implantable Electronic Device Implantation and Its Impact on Mortality and Hospitalization: A Single-Center Cohort Study.","authors":"Ahmet Can Urgancı, Filiz Özerkan Çakan, Evrim Şimşek","doi":"10.1111/jce.70532","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Tricuspid regurgitation (TR) progression is a recognized complication of cardiac implantable electronic device (CIED) implantation, yet its prognostic impact on long-term clinical outcomes remains incompletely defined.</p><p><strong>Methods and results: </strong>In this single-center retrospective cohort, 303 patients undergoing CIED implantation between 2005 and 2023 were followed for a median of 4.8 years. TR severity was assessed echocardiographically at baseline and 12 months. The primary endpoint was TR progression (≥ 1-grade worsening); secondary endpoints were all-cause mortality, cardiovascular hospitalization, their composite, and progression to severe TR, analyzed by Kaplan-Meier and Cox regression. TR progressed in 103 patients (34.0%), regressed in 33 (10.9%), and remained stable in 167 (55.1%), a net rightward shift (p < 0.001). Progression differed by device type (p = 0.031): among the larger subgroups, VVI-ICD showed the greatest net progression (31.8% worsened vs. 6.9% improved; p < 0.001) and CRT-D the highest regression (18.8%). During follow-up, 67 patients (22.1%) died and 164 (54.1%) were hospitalized. Overall TR progression was not independently associated with mortality (HR 1.118, p = 0.693) but independently predicted cardiovascular hospitalization (HR 1.640, p = 0.003) and the composite endpoint (HR 1.480, p = 0.014). On unadjusted analysis, progression specifically to severe TR (n = 15) was associated with increased mortality (HR 1.99, p = 0.024) and cardiovascular hospitalization (HR 2.45, p < 0.001).</p><p><strong>Conclusion: </strong>TR progression occurs in approximately one-third of CIED recipients within the first year and independently predicts cardiovascular hospitalization. Progression to severe TR identifies a higher-risk subset, supporting routine post-implant echocardiographic surveillance.</p>","PeriodicalId":15178,"journal":{"name":"Journal of Cardiovascular Electrophysiology","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2026-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jce.70532","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Tricuspid regurgitation (TR) progression is a recognized complication of cardiac implantable electronic device (CIED) implantation, yet its prognostic impact on long-term clinical outcomes remains incompletely defined.
Methods and results: In this single-center retrospective cohort, 303 patients undergoing CIED implantation between 2005 and 2023 were followed for a median of 4.8 years. TR severity was assessed echocardiographically at baseline and 12 months. The primary endpoint was TR progression (≥ 1-grade worsening); secondary endpoints were all-cause mortality, cardiovascular hospitalization, their composite, and progression to severe TR, analyzed by Kaplan-Meier and Cox regression. TR progressed in 103 patients (34.0%), regressed in 33 (10.9%), and remained stable in 167 (55.1%), a net rightward shift (p < 0.001). Progression differed by device type (p = 0.031): among the larger subgroups, VVI-ICD showed the greatest net progression (31.8% worsened vs. 6.9% improved; p < 0.001) and CRT-D the highest regression (18.8%). During follow-up, 67 patients (22.1%) died and 164 (54.1%) were hospitalized. Overall TR progression was not independently associated with mortality (HR 1.118, p = 0.693) but independently predicted cardiovascular hospitalization (HR 1.640, p = 0.003) and the composite endpoint (HR 1.480, p = 0.014). On unadjusted analysis, progression specifically to severe TR (n = 15) was associated with increased mortality (HR 1.99, p = 0.024) and cardiovascular hospitalization (HR 2.45, p < 0.001).
Conclusion: TR progression occurs in approximately one-third of CIED recipients within the first year and independently predicts cardiovascular hospitalization. Progression to severe TR identifies a higher-risk subset, supporting routine post-implant echocardiographic surveillance.
期刊介绍:
Journal of Cardiovascular Electrophysiology (JCE) keeps its readership well informed of the latest developments in the study and management of arrhythmic disorders. Edited by Bradley P. Knight, M.D., and a distinguished international editorial board, JCE is the leading journal devoted to the study of the electrophysiology of the heart.