Progression of Tricuspid Regurgitation After Cardiac Implantable Electronic Device Implantation and Its Impact on Mortality and Hospitalization: A Single-Center Cohort Study.

IF 2.4 3区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Ahmet Can Urgancı, Filiz Özerkan Çakan, Evrim Şimşek
{"title":"Progression of Tricuspid Regurgitation After Cardiac Implantable Electronic Device Implantation and Its Impact on Mortality and Hospitalization: A Single-Center Cohort Study.","authors":"Ahmet Can Urgancı, Filiz Özerkan Çakan, Evrim Şimşek","doi":"10.1111/jce.70532","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Tricuspid regurgitation (TR) progression is a recognized complication of cardiac implantable electronic device (CIED) implantation, yet its prognostic impact on long-term clinical outcomes remains incompletely defined.</p><p><strong>Methods and results: </strong>In this single-center retrospective cohort, 303 patients undergoing CIED implantation between 2005 and 2023 were followed for a median of 4.8 years. TR severity was assessed echocardiographically at baseline and 12 months. The primary endpoint was TR progression (≥ 1-grade worsening); secondary endpoints were all-cause mortality, cardiovascular hospitalization, their composite, and progression to severe TR, analyzed by Kaplan-Meier and Cox regression. TR progressed in 103 patients (34.0%), regressed in 33 (10.9%), and remained stable in 167 (55.1%), a net rightward shift (p < 0.001). Progression differed by device type (p = 0.031): among the larger subgroups, VVI-ICD showed the greatest net progression (31.8% worsened vs. 6.9% improved; p < 0.001) and CRT-D the highest regression (18.8%). During follow-up, 67 patients (22.1%) died and 164 (54.1%) were hospitalized. Overall TR progression was not independently associated with mortality (HR 1.118, p = 0.693) but independently predicted cardiovascular hospitalization (HR 1.640, p = 0.003) and the composite endpoint (HR 1.480, p = 0.014). On unadjusted analysis, progression specifically to severe TR (n = 15) was associated with increased mortality (HR 1.99, p = 0.024) and cardiovascular hospitalization (HR 2.45, p < 0.001).</p><p><strong>Conclusion: </strong>TR progression occurs in approximately one-third of CIED recipients within the first year and independently predicts cardiovascular hospitalization. Progression to severe TR identifies a higher-risk subset, supporting routine post-implant echocardiographic surveillance.</p>","PeriodicalId":15178,"journal":{"name":"Journal of Cardiovascular Electrophysiology","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2026-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jce.70532","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Tricuspid regurgitation (TR) progression is a recognized complication of cardiac implantable electronic device (CIED) implantation, yet its prognostic impact on long-term clinical outcomes remains incompletely defined.

Methods and results: In this single-center retrospective cohort, 303 patients undergoing CIED implantation between 2005 and 2023 were followed for a median of 4.8 years. TR severity was assessed echocardiographically at baseline and 12 months. The primary endpoint was TR progression (≥ 1-grade worsening); secondary endpoints were all-cause mortality, cardiovascular hospitalization, their composite, and progression to severe TR, analyzed by Kaplan-Meier and Cox regression. TR progressed in 103 patients (34.0%), regressed in 33 (10.9%), and remained stable in 167 (55.1%), a net rightward shift (p < 0.001). Progression differed by device type (p = 0.031): among the larger subgroups, VVI-ICD showed the greatest net progression (31.8% worsened vs. 6.9% improved; p < 0.001) and CRT-D the highest regression (18.8%). During follow-up, 67 patients (22.1%) died and 164 (54.1%) were hospitalized. Overall TR progression was not independently associated with mortality (HR 1.118, p = 0.693) but independently predicted cardiovascular hospitalization (HR 1.640, p = 0.003) and the composite endpoint (HR 1.480, p = 0.014). On unadjusted analysis, progression specifically to severe TR (n = 15) was associated with increased mortality (HR 1.99, p = 0.024) and cardiovascular hospitalization (HR 2.45, p < 0.001).

Conclusion: TR progression occurs in approximately one-third of CIED recipients within the first year and independently predicts cardiovascular hospitalization. Progression to severe TR identifies a higher-risk subset, supporting routine post-implant echocardiographic surveillance.

心脏植入式电子装置植入后三尖瓣反流的进展及其对死亡率和住院率的影响:一项单中心队列研究
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.20
自引率
14.80%
发文量
433
审稿时长
3-6 weeks
期刊介绍: Journal of Cardiovascular Electrophysiology (JCE) keeps its readership well informed of the latest developments in the study and management of arrhythmic disorders. Edited by Bradley P. Knight, M.D., and a distinguished international editorial board, JCE is the leading journal devoted to the study of the electrophysiology of the heart.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书