New Mixed-Reality Navigation System for Cup Positioning in Trapeziometacarpal Arthroplasty: An In Vitro Validation Study.

IF 0.5 Q4 SURGERY
David Mayorga-Naranjo, Carmen García-Espert, Cristina Ramírez-Fuentes, Alfonso Valverde-Navarro, Joan Ferràs-Tarragó
{"title":"New Mixed-Reality Navigation System for Cup Positioning in Trapeziometacarpal Arthroplasty: An In Vitro Validation Study.","authors":"David Mayorga-Naranjo, Carmen García-Espert, Cristina Ramírez-Fuentes, Alfonso Valverde-Navarro, Joan Ferràs-Tarragó","doi":"10.1142/S2424835526500542","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> To describe and validate a novel mixed-reality (MR) navigation system for cup positioning in trapeziometacarpal arthroplasty and to assess its accuracy and reproducibility compared with the conventional freehand technique. <b>Methods:</b> A trackerless holographic navigation software for Microsoft HoloLens 2 was developed to provide real-time holographic feedback of anteversion and inclination during guidewire insertion. Two in vitro studies were performed. First, geometric trapezoidal models (<i>n</i> = 80) were used, in which an orthopaedic resident and an expert hand surgeon inserted Kirschner wires freehand and with navigation. Second, anatomical trapezium bio-models (<i>n</i> = 20) were used, with an expert surgeon performing freehand (<i>n</i> = 10) and navigated (<i>n</i> = 10) insertions. Postoperative CT quantified angular deviation from planned targets. Results were analysed using Student's <i>t</i>-test and Bartlett's test. <b>Results:</b> In geometric models, the pooled total mean absolute error was 6.99° (SD = 4.92°, 95% CI 3.47-10.52) for the freehand technique and 0.65° (SD = 0.26°, 95% CI 0.47-0.84) for MR guidance, with a mean paired difference of 6.34° favouring navigation (<i>p</i> = 0.002). Anteversion and inclination errors were significantly lower, and variability was reduced (Bartlett <i>p</i> < 0.01). No significant differences were observed between operators under MR guidance. In anatomical bio-models, MR guidance significantly reduced the overall mean angular error from 9.10° to 0.68° (<i>p</i> = 0.0004), while both anteversion and inclination errors were also significantly lower than with the conventional freehand technique. <b>Conclusions:</b> In this in vitro study, MR navigation substantially improves the accuracy and reproducibility of guidewire placement for trapeziometacarpal cup positioning compared with the freehand technique, while reducing variability and operator dependence. Clinical studies are required to determine its impact on intraoperative workflow and patient outcomes.</p>","PeriodicalId":51689,"journal":{"name":"Journal of Hand Surgery-Asian-Pacific Volume","volume":" ","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2026-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hand Surgery-Asian-Pacific Volume","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/S2424835526500542","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: To describe and validate a novel mixed-reality (MR) navigation system for cup positioning in trapeziometacarpal arthroplasty and to assess its accuracy and reproducibility compared with the conventional freehand technique. Methods: A trackerless holographic navigation software for Microsoft HoloLens 2 was developed to provide real-time holographic feedback of anteversion and inclination during guidewire insertion. Two in vitro studies were performed. First, geometric trapezoidal models (n = 80) were used, in which an orthopaedic resident and an expert hand surgeon inserted Kirschner wires freehand and with navigation. Second, anatomical trapezium bio-models (n = 20) were used, with an expert surgeon performing freehand (n = 10) and navigated (n = 10) insertions. Postoperative CT quantified angular deviation from planned targets. Results were analysed using Student's t-test and Bartlett's test. Results: In geometric models, the pooled total mean absolute error was 6.99° (SD = 4.92°, 95% CI 3.47-10.52) for the freehand technique and 0.65° (SD = 0.26°, 95% CI 0.47-0.84) for MR guidance, with a mean paired difference of 6.34° favouring navigation (p = 0.002). Anteversion and inclination errors were significantly lower, and variability was reduced (Bartlett p < 0.01). No significant differences were observed between operators under MR guidance. In anatomical bio-models, MR guidance significantly reduced the overall mean angular error from 9.10° to 0.68° (p = 0.0004), while both anteversion and inclination errors were also significantly lower than with the conventional freehand technique. Conclusions: In this in vitro study, MR navigation substantially improves the accuracy and reproducibility of guidewire placement for trapeziometacarpal cup positioning compared with the freehand technique, while reducing variability and operator dependence. Clinical studies are required to determine its impact on intraoperative workflow and patient outcomes.

新型混合现实导航系统用于斜腕关节成形术中的杯形定位:一项体外验证研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.90
自引率
0.00%
发文量
304
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书