{"title":"Comparison of manual palpation, 2D carotid ultrasound, and end-tidal carbon dioxide for detecting return of spontaneous circulation.","authors":"Akin Gullu, Sukru Kockan, Emre Sanci, Erdem Aydin, Ahmet Emir Sari, Asim Enes Ozbek, Huseyin Cahit Halhalli","doi":"10.15441/ceem.25.113","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Healthcare providers frequently spend excessive time attempting to identify a pulse and may have difficulty accurately confirming its presence. Point-of-care carotid artery ultrasonography has been suggested as a potential alternative to manual palpation. This study aimed to evaluate the effectiveness of manual palpation, 2D carotid ultrasonography, and rapid increases in end-tidal carbon dioxide (EtCO2) levels for determining the return of spontaneous circulation (ROSC) in patients with cardiac arrest presenting to an emergency department.</p><p><strong>Methods: </strong>This was a single-center, prospective, observational study. Nontraumatic adult patients in cardiopulmonary arrest who were brought to the emergency department were included. After cardiac arrest was identified, the following data were recorded: initial arrest rhythm, ultrasonographic and manual pulse assessments, EtCO2 levels, resuscitation duration, and post-ROSC vital signs. The team leader's judgment was used for ROSC adjudication and served as the reference standard.</p><p><strong>Results: </strong>The investigation included 88 patients who underwent a total of 642 cycles of cardiopulmonary resuscitation. The area under the curve (AUC) values for 2D carotid ultrasonography, EtCO2, and manual palpation were 0.974, 0.802, and 0.862, respectively (all P<0.001). In pairwise AUC comparisons, ultrasonography differed significantly from manual palpation (P=0.001) and EtCO2 (P<0.001), whereas manual palpation and EtCO2 did not differ significantly (P=0.167). Bedside ultrasonography for detecting a carotid pulse had a sensitivity of 93.8% and a specificity of 100%.</p><p><strong>Conclusion: </strong>These findings suggest that 2D carotid ultrasonography can be effectively used to detect a pulse in patients with cardiopulmonary arrest.</p>","PeriodicalId":10325,"journal":{"name":"Clinical and Experimental Emergency Medicine","volume":"13 3","pages":"311-317"},"PeriodicalIF":3.4000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13654665/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Experimental Emergency Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15441/ceem.25.113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Healthcare providers frequently spend excessive time attempting to identify a pulse and may have difficulty accurately confirming its presence. Point-of-care carotid artery ultrasonography has been suggested as a potential alternative to manual palpation. This study aimed to evaluate the effectiveness of manual palpation, 2D carotid ultrasonography, and rapid increases in end-tidal carbon dioxide (EtCO2) levels for determining the return of spontaneous circulation (ROSC) in patients with cardiac arrest presenting to an emergency department.
Methods: This was a single-center, prospective, observational study. Nontraumatic adult patients in cardiopulmonary arrest who were brought to the emergency department were included. After cardiac arrest was identified, the following data were recorded: initial arrest rhythm, ultrasonographic and manual pulse assessments, EtCO2 levels, resuscitation duration, and post-ROSC vital signs. The team leader's judgment was used for ROSC adjudication and served as the reference standard.
Results: The investigation included 88 patients who underwent a total of 642 cycles of cardiopulmonary resuscitation. The area under the curve (AUC) values for 2D carotid ultrasonography, EtCO2, and manual palpation were 0.974, 0.802, and 0.862, respectively (all P<0.001). In pairwise AUC comparisons, ultrasonography differed significantly from manual palpation (P=0.001) and EtCO2 (P<0.001), whereas manual palpation and EtCO2 did not differ significantly (P=0.167). Bedside ultrasonography for detecting a carotid pulse had a sensitivity of 93.8% and a specificity of 100%.
Conclusion: These findings suggest that 2D carotid ultrasonography can be effectively used to detect a pulse in patients with cardiopulmonary arrest.