Comparison of manual palpation, 2D carotid ultrasound, and end-tidal carbon dioxide for detecting return of spontaneous circulation.

IF 3.4 Q2 EMERGENCY MEDICINE
Clinical and Experimental Emergency Medicine Pub Date : 2026-09-01 Epub Date: 2026-01-28 DOI:10.15441/ceem.25.113
Akin Gullu, Sukru Kockan, Emre Sanci, Erdem Aydin, Ahmet Emir Sari, Asim Enes Ozbek, Huseyin Cahit Halhalli
{"title":"Comparison of manual palpation, 2D carotid ultrasound, and end-tidal carbon dioxide for detecting return of spontaneous circulation.","authors":"Akin Gullu, Sukru Kockan, Emre Sanci, Erdem Aydin, Ahmet Emir Sari, Asim Enes Ozbek, Huseyin Cahit Halhalli","doi":"10.15441/ceem.25.113","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Healthcare providers frequently spend excessive time attempting to identify a pulse and may have difficulty accurately confirming its presence. Point-of-care carotid artery ultrasonography has been suggested as a potential alternative to manual palpation. This study aimed to evaluate the effectiveness of manual palpation, 2D carotid ultrasonography, and rapid increases in end-tidal carbon dioxide (EtCO2) levels for determining the return of spontaneous circulation (ROSC) in patients with cardiac arrest presenting to an emergency department.</p><p><strong>Methods: </strong>This was a single-center, prospective, observational study. Nontraumatic adult patients in cardiopulmonary arrest who were brought to the emergency department were included. After cardiac arrest was identified, the following data were recorded: initial arrest rhythm, ultrasonographic and manual pulse assessments, EtCO2 levels, resuscitation duration, and post-ROSC vital signs. The team leader's judgment was used for ROSC adjudication and served as the reference standard.</p><p><strong>Results: </strong>The investigation included 88 patients who underwent a total of 642 cycles of cardiopulmonary resuscitation. The area under the curve (AUC) values for 2D carotid ultrasonography, EtCO2, and manual palpation were 0.974, 0.802, and 0.862, respectively (all P<0.001). In pairwise AUC comparisons, ultrasonography differed significantly from manual palpation (P=0.001) and EtCO2 (P<0.001), whereas manual palpation and EtCO2 did not differ significantly (P=0.167). Bedside ultrasonography for detecting a carotid pulse had a sensitivity of 93.8% and a specificity of 100%.</p><p><strong>Conclusion: </strong>These findings suggest that 2D carotid ultrasonography can be effectively used to detect a pulse in patients with cardiopulmonary arrest.</p>","PeriodicalId":10325,"journal":{"name":"Clinical and Experimental Emergency Medicine","volume":"13 3","pages":"311-317"},"PeriodicalIF":3.4000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13654665/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Experimental Emergency Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15441/ceem.25.113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Healthcare providers frequently spend excessive time attempting to identify a pulse and may have difficulty accurately confirming its presence. Point-of-care carotid artery ultrasonography has been suggested as a potential alternative to manual palpation. This study aimed to evaluate the effectiveness of manual palpation, 2D carotid ultrasonography, and rapid increases in end-tidal carbon dioxide (EtCO2) levels for determining the return of spontaneous circulation (ROSC) in patients with cardiac arrest presenting to an emergency department.

Methods: This was a single-center, prospective, observational study. Nontraumatic adult patients in cardiopulmonary arrest who were brought to the emergency department were included. After cardiac arrest was identified, the following data were recorded: initial arrest rhythm, ultrasonographic and manual pulse assessments, EtCO2 levels, resuscitation duration, and post-ROSC vital signs. The team leader's judgment was used for ROSC adjudication and served as the reference standard.

Results: The investigation included 88 patients who underwent a total of 642 cycles of cardiopulmonary resuscitation. The area under the curve (AUC) values for 2D carotid ultrasonography, EtCO2, and manual palpation were 0.974, 0.802, and 0.862, respectively (all P<0.001). In pairwise AUC comparisons, ultrasonography differed significantly from manual palpation (P=0.001) and EtCO2 (P<0.001), whereas manual palpation and EtCO2 did not differ significantly (P=0.167). Bedside ultrasonography for detecting a carotid pulse had a sensitivity of 93.8% and a specificity of 100%.

Conclusion: These findings suggest that 2D carotid ultrasonography can be effectively used to detect a pulse in patients with cardiopulmonary arrest.

手工触诊、颈动脉二维超声和潮末二氧化碳检测自发循环恢复的比较。
目的:医疗保健提供者经常花费过多的时间试图识别脉搏,并可能难以准确确认其存在。点护理颈动脉超声检查已被建议作为一个潜在的替代手动触诊。本研究旨在评估手诊、二维颈动脉超声检查和潮末二氧化碳(EtCO2)水平快速升高对急诊科心脏骤停患者自发循环(ROSC)恢复的影响。方法:这是一项单中心、前瞻性观察性研究。被送到急诊科的非创伤性成人心肺骤停患者也包括在内。发现心脏骤停后,记录以下数据:初始骤停节律、超声和手动脉搏评估、EtCO2水平、复苏持续时间和rosc后生命体征。领队的判断作为ROSC评审的参考标准。结果:共88例患者接受了642个周期的心肺复苏。二维颈动脉超声、EtCO2、手诊的曲线下面积(AUC)分别为0.974、0.802、0.862(均为p)。结论:二维颈动脉超声可有效检测心肺骤停患者的脉搏。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.80
自引率
10.50%
发文量
59
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书