The Feasibility and Sustainability of Microcystis aeruginosa Removal with Nanobubble-Assisted Coagulation Using Polyaluminum Chloride (PACl) under Real Drinking Water Conditions
{"title":"The Feasibility and Sustainability of Microcystis aeruginosa Removal with Nanobubble-Assisted Coagulation Using Polyaluminum Chloride (PACl) under Real Drinking Water Conditions","authors":"Paramon Koutorjevski, Qian Zhang, Xiaying Xin","doi":"10.1021/acsestwater.6c00738","DOIUrl":null,"url":null,"abstract":"<p>Inorganic\r\ncoagulants such as polyaluminum chloride (PACl) are widely\r\nused in conventional drinking water treatment systems to effectively\r\nreduce turbidity and remove contaminants across diverse water matrices;\r\nhowever, they are associated with high chemical demand, operational\r\ncosts, and potential health and environmental concerns. This study\r\ndemonstrates that integrating nonmodified nanobubbles (NBs) during\r\nthe rapid-mixing stage of the coagulation process (NB-assisted coagulation)\r\nconsiderably enhances treatment performance compared to using PACl\r\nalone. Experiments were conducted in water samples collected from\r\nLake Ontario to evaluate the performance of NB-assisted coagulation\r\nin real-water matrices. <em>Microcystis aeruginosa</em> was\r\nemployed as a model contaminant due to its relevance as an emerging\r\nissue in water treatment systems and its ability to indicate intracellular\r\ncyanotoxin release via potential cell lysis. Results showed that cyanotoxin\r\nconcentrations in NB-assisted systems were comparable to those in\r\nconventional coagulation, confirming that NBs do not disrupt cells\r\nor induce toxin release. Moreover, NB-assisted coagulation achieved\r\nequivalent or improved contaminant removal efficiency at reduced coagulant\r\ndosages, thereby lowering chemical consumption and the environmental\r\nfootprint. The sustainability and economic benefits were further evaluated\r\nthrough a life cycle assessment and cost analysis for a hypothetical\r\nwater treatment system incorporating an NB generator.</p>","PeriodicalId":93847,"journal":{"name":"ACS ES&T water","volume":"6 10","pages":"6576–6589"},"PeriodicalIF":4.5000,"publicationDate":"2026-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS ES&T water","FirstCategoryId":"1085","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acsestwater.6c00738","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/7 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Inorganic
coagulants such as polyaluminum chloride (PACl) are widely
used in conventional drinking water treatment systems to effectively
reduce turbidity and remove contaminants across diverse water matrices;
however, they are associated with high chemical demand, operational
costs, and potential health and environmental concerns. This study
demonstrates that integrating nonmodified nanobubbles (NBs) during
the rapid-mixing stage of the coagulation process (NB-assisted coagulation)
considerably enhances treatment performance compared to using PACl
alone. Experiments were conducted in water samples collected from
Lake Ontario to evaluate the performance of NB-assisted coagulation
in real-water matrices. Microcystis aeruginosa was
employed as a model contaminant due to its relevance as an emerging
issue in water treatment systems and its ability to indicate intracellular
cyanotoxin release via potential cell lysis. Results showed that cyanotoxin
concentrations in NB-assisted systems were comparable to those in
conventional coagulation, confirming that NBs do not disrupt cells
or induce toxin release. Moreover, NB-assisted coagulation achieved
equivalent or improved contaminant removal efficiency at reduced coagulant
dosages, thereby lowering chemical consumption and the environmental
footprint. The sustainability and economic benefits were further evaluated
through a life cycle assessment and cost analysis for a hypothetical
water treatment system incorporating an NB generator.