A Controlled Single-Speaker Evaluation of Ambient Voice Technologies' Speech-to-Text Function Using Narrated Surgical Case-Reports.

IF 8.8 3区 医学 Q1 HEALTH CARE SCIENCES & SERVICES
Ruairi O'Kane, Daniel Stonehouse-Smith, Melody Shirazi, Rachel Hutchinson, Morgan Gregg, Riya Patel, Jadbinder Seehra, Spyridon N Papageorgiou, Martyn T Cobourne
{"title":"A Controlled Single-Speaker Evaluation of Ambient Voice Technologies' Speech-to-Text Function Using Narrated Surgical Case-Reports.","authors":"Ruairi O'Kane, Daniel Stonehouse-Smith, Melody Shirazi, Rachel Hutchinson, Morgan Gregg, Riya Patel, Jadbinder Seehra, Spyridon N Papageorgiou, Martyn T Cobourne","doi":"10.1007/s10916-026-02471-5","DOIUrl":null,"url":null,"abstract":"<p><p>Ambient voice technologies (AVT) utilise automatic speech recognition (ASR) and generative artificial intelligence for speech-to-text conversion, and are advocated as efficient, accurate tools for clinical documentation. We investigated (n = 8) AVT systems using surgical case-reports as narratives in a controlled single-speaker evaluation prioritising safety outcomes: specifically 3 commercial transcription-systems (Dragon-Medical-One, Heidi-Health, Tortus); 4 ASR speech-to-text Application Programming Interfaces (Speechmatics-Enhanced, Amazon-Medical-Transcribe, Whisper, GPT4oTranscribe); and an experimental two-stage ASR-Large Language Model (LLM) pipeline incorporating GPT4oTranscribe with GPT-5-LLM generative error correction (GPT4oTranscribe-Corrected-5). Reference-transcripts (n = 100; 32,897 words, range = 44-449, mean = 329/per-transcript) derived from surgical case-reports were recorded and input into AVT systems as audio-recordings for transcription-output generation. Primary outcome was proportion of transcription-outputs containing at least one clinically significant Class 3 error graded for potential harm. Secondary outcomes included transcription accuracy: Domain-Word-Error-Rate (DWER) against SNOMED-CT, lexical-accuracy (ROUGE score) and semantic similarity (BERT, BART scores). To investigate impact of the experimental pipeline on clinically significant errors, raw ASR and LLM-processed transcription-outputs were compared and errors classified as resolved, remaining or newly introduced. Across (n = 800) transcript-outputs, 30-68% (GPT4oTranscribe-Corrected-5; Amazon-Medical-Transcribe and Dragon-Medical-One, respectively) contained at least one clinically significant Class 3 error. LLM-processing reduced the proportion of transcript-outputs affected (53% to 30%), amongst 89 clinically significant errors in ASR-output, 51 were resolved, 38 remained significant and 4 were newly introduced. Reference-transcript length significantly increased odds of Class 3 errors for 4 systems (GPT4oTranscribe, Tortus, Amazon-Medical-Transcribe, Dragon-Medical-One; odds ratio 2.65-3.34/additional 100 reference-words). Errors with potential to cause severe harm or death (NHS England Level 3-4) totalled (n = 53) across systems, concentrated in the domains of medication-type/dose (39.6%), and investigations/laboratory results (30.2%). Performance varied across systems for transcription metrics (P < 0.001). GPT4oTranscribe-Corrected-5 (DWER = 3.60%) and Heidi-Health (DWER = 5.67%) performed best for medical terminology; Amazon-Medical-Transcribe worst (DWER = 24.03%). For lexical and semantic similarity GPT4oTranscribe-Corrected-5 performed best, followed by Heidi-Health. The ASR-LLM pipeline reduced clinically significant errors but did introduce new ones in 3% of transcript-outputs. The safety and effectiveness of these systems in clinical practice requires further evaluation.</p>","PeriodicalId":16338,"journal":{"name":"Journal of Medical Systems","volume":"50 1","pages":""},"PeriodicalIF":8.8000,"publicationDate":"2026-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13652911/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Systems","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10916-026-02471-5","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

Abstract

Ambient voice technologies (AVT) utilise automatic speech recognition (ASR) and generative artificial intelligence for speech-to-text conversion, and are advocated as efficient, accurate tools for clinical documentation. We investigated (n = 8) AVT systems using surgical case-reports as narratives in a controlled single-speaker evaluation prioritising safety outcomes: specifically 3 commercial transcription-systems (Dragon-Medical-One, Heidi-Health, Tortus); 4 ASR speech-to-text Application Programming Interfaces (Speechmatics-Enhanced, Amazon-Medical-Transcribe, Whisper, GPT4oTranscribe); and an experimental two-stage ASR-Large Language Model (LLM) pipeline incorporating GPT4oTranscribe with GPT-5-LLM generative error correction (GPT4oTranscribe-Corrected-5). Reference-transcripts (n = 100; 32,897 words, range = 44-449, mean = 329/per-transcript) derived from surgical case-reports were recorded and input into AVT systems as audio-recordings for transcription-output generation. Primary outcome was proportion of transcription-outputs containing at least one clinically significant Class 3 error graded for potential harm. Secondary outcomes included transcription accuracy: Domain-Word-Error-Rate (DWER) against SNOMED-CT, lexical-accuracy (ROUGE score) and semantic similarity (BERT, BART scores). To investigate impact of the experimental pipeline on clinically significant errors, raw ASR and LLM-processed transcription-outputs were compared and errors classified as resolved, remaining or newly introduced. Across (n = 800) transcript-outputs, 30-68% (GPT4oTranscribe-Corrected-5; Amazon-Medical-Transcribe and Dragon-Medical-One, respectively) contained at least one clinically significant Class 3 error. LLM-processing reduced the proportion of transcript-outputs affected (53% to 30%), amongst 89 clinically significant errors in ASR-output, 51 were resolved, 38 remained significant and 4 were newly introduced. Reference-transcript length significantly increased odds of Class 3 errors for 4 systems (GPT4oTranscribe, Tortus, Amazon-Medical-Transcribe, Dragon-Medical-One; odds ratio 2.65-3.34/additional 100 reference-words). Errors with potential to cause severe harm or death (NHS England Level 3-4) totalled (n = 53) across systems, concentrated in the domains of medication-type/dose (39.6%), and investigations/laboratory results (30.2%). Performance varied across systems for transcription metrics (P < 0.001). GPT4oTranscribe-Corrected-5 (DWER = 3.60%) and Heidi-Health (DWER = 5.67%) performed best for medical terminology; Amazon-Medical-Transcribe worst (DWER = 24.03%). For lexical and semantic similarity GPT4oTranscribe-Corrected-5 performed best, followed by Heidi-Health. The ASR-LLM pipeline reduced clinically significant errors but did introduce new ones in 3% of transcript-outputs. The safety and effectiveness of these systems in clinical practice requires further evaluation.

使用叙述的外科病例报告对环境语音技术的语音转文本功能进行受控单说话人评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Medical Systems
Journal of Medical Systems 医学-卫生保健
CiteScore
11.60
自引率
1.90%
发文量
83
审稿时长
4.8 months
期刊介绍: Journal of Medical Systems provides a forum for the presentation and discussion of the increasingly extensive applications of new systems techniques and methods in hospital clinic and physician''s office administration; pathology radiology and pharmaceutical delivery systems; medical records storage and retrieval; and ancillary patient-support systems. The journal publishes informative articles essays and studies across the entire scale of medical systems from large hospital programs to novel small-scale medical services. Education is an integral part of this amalgamation of sciences and selected articles are published in this area. Since existing medical systems are constantly being modified to fit particular circumstances and to solve specific problems the journal includes a special section devoted to status reports on current installations.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书