Oana M Mereuta, Julien Ognard, William G Loudon, Esref Alperen Bayraktar, Yasuhito Ueki, Daying Dai, Jack Weissberg, Suehyun Cho, Evaline Wang, Teresa Yuan, Anish Vaghela, Xiaobo Ma, Sarah Lortscher, Dan R Montonye, Christopher K Gow, Edward S Ahn, Waleed Brinjikji, Ramanathan Kadirvel
{"title":"Magnetically guided microrobot via minimally invasive percutaneous cisternal access: a first preclinical evaluation.","authors":"Oana M Mereuta, Julien Ognard, William G Loudon, Esref Alperen Bayraktar, Yasuhito Ueki, Daying Dai, Jack Weissberg, Suehyun Cho, Evaline Wang, Teresa Yuan, Anish Vaghela, Xiaobo Ma, Sarah Lortscher, Dan R Montonye, Christopher K Gow, Edward S Ahn, Waleed Brinjikji, Ramanathan Kadirvel","doi":"10.3171/2026.4.JNS252541","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Magnetically guided microrobots could enable minimally invasive intracranial interventions by navigating CSF spaces without traversing brain parenchyma. However, clinical translation requires in vivo validation of delivery, control, retrieval, and short-term safety under realistic workflow conditions. The aim of this study was to assess the feasibility and initial safety of percutaneous cisterna magna access, microrobot navigation, and retrieval using an image-integrated electromagnetic coil platform in a large-animal model, targeting future application to Dandy-Walker malformation cyst fenestration.</p><p><strong>Methods: </strong>In this Good Laboratory Practice-compliant ovine study, 7 male sheep were allocated to an MRI-only control group (n = 1), flexion control group (n = 1), and treatment group (n = 3; percutaneous cisternal access, deployment of a 3.5 × 7-mm Parylene-C-coated bladed microrobot with a neodymium core, magnetic navigation, scripted dwell, and retrieval), with 2 animals designated as alternates. Preoperative MRI was used for planning, with intraoperative cone-beam CT fusion and biplanar fluoroscopy. The follow-up period was 28 days and included daily observation, weekly neurological examination, and analysis of hematology/chemistry, intraoperative CSF, and terminal necropsy with histopathology. Outcomes were descriptive.</p><p><strong>Results: </strong>The full workflow was completed in all 3 treated animals without conversion or rescue. Cannulation succeeded on the first attempt; continuous fluoroscopic visibility and stable magnetic control were maintained; and retrieval succeeded in a single maneuver. Postoperative recovery was uneventful, with weight gain and no neurological deficits over 28 days of follow-up. Laboratory values were within reference ranges except for 1 case of transient leukocytosis (day 0) that resolved. CSF was acellular/normal. Necropsy showed localized procedure-site changes only (dural fibrosis, thin adhesions in 2 of 3 treated animals). Histology revealed focal superficial vermian gliosis ≤ 2 mm in 2 of 3 treated animals without hemorrhage, necrosis, or off-target injury, and controls were within normal limits (1 case of minimal incidental axonal change in the flexion control).</p><p><strong>Conclusions: </strong>Percutaneous cisternal delivery and retrieval of an untethered microrobot were feasible and tolerated in sheep, with localized tissue responses at 28 days. These findings support further studies focused on longer follow-up, workflow optimization, and disease-specific efficacy.</p>","PeriodicalId":16505,"journal":{"name":"Journal of neurosurgery","volume":" ","pages":"1-11"},"PeriodicalIF":3.8000,"publicationDate":"2026-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neurosurgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3171/2026.4.JNS252541","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Magnetically guided microrobots could enable minimally invasive intracranial interventions by navigating CSF spaces without traversing brain parenchyma. However, clinical translation requires in vivo validation of delivery, control, retrieval, and short-term safety under realistic workflow conditions. The aim of this study was to assess the feasibility and initial safety of percutaneous cisterna magna access, microrobot navigation, and retrieval using an image-integrated electromagnetic coil platform in a large-animal model, targeting future application to Dandy-Walker malformation cyst fenestration.
Methods: In this Good Laboratory Practice-compliant ovine study, 7 male sheep were allocated to an MRI-only control group (n = 1), flexion control group (n = 1), and treatment group (n = 3; percutaneous cisternal access, deployment of a 3.5 × 7-mm Parylene-C-coated bladed microrobot with a neodymium core, magnetic navigation, scripted dwell, and retrieval), with 2 animals designated as alternates. Preoperative MRI was used for planning, with intraoperative cone-beam CT fusion and biplanar fluoroscopy. The follow-up period was 28 days and included daily observation, weekly neurological examination, and analysis of hematology/chemistry, intraoperative CSF, and terminal necropsy with histopathology. Outcomes were descriptive.
Results: The full workflow was completed in all 3 treated animals without conversion or rescue. Cannulation succeeded on the first attempt; continuous fluoroscopic visibility and stable magnetic control were maintained; and retrieval succeeded in a single maneuver. Postoperative recovery was uneventful, with weight gain and no neurological deficits over 28 days of follow-up. Laboratory values were within reference ranges except for 1 case of transient leukocytosis (day 0) that resolved. CSF was acellular/normal. Necropsy showed localized procedure-site changes only (dural fibrosis, thin adhesions in 2 of 3 treated animals). Histology revealed focal superficial vermian gliosis ≤ 2 mm in 2 of 3 treated animals without hemorrhage, necrosis, or off-target injury, and controls were within normal limits (1 case of minimal incidental axonal change in the flexion control).
Conclusions: Percutaneous cisternal delivery and retrieval of an untethered microrobot were feasible and tolerated in sheep, with localized tissue responses at 28 days. These findings support further studies focused on longer follow-up, workflow optimization, and disease-specific efficacy.
期刊介绍:
The Journal of Neurosurgery, Journal of Neurosurgery: Spine, Journal of Neurosurgery: Pediatrics, and Neurosurgical Focus are devoted to the publication of original works relating primarily to neurosurgery, including studies in clinical neurophysiology, organic neurology, ophthalmology, radiology, pathology, and molecular biology. The Editors and Editorial Boards encourage submission of clinical and laboratory studies. Other manuscripts accepted for review include technical notes on instruments or equipment that are innovative or useful to clinicians and researchers in the field of neuroscience; papers describing unusual cases; manuscripts on historical persons or events related to neurosurgery; and in Neurosurgical Focus, occasional reviews. Letters to the Editor commenting on articles recently published in the Journal of Neurosurgery, Journal of Neurosurgery: Spine, and Journal of Neurosurgery: Pediatrics are welcome.