Accuracy of complete-arch implant positions recorded by analog impressions, intraoral scanning, and extraoral and intraoral photogrammetry.

IF 3.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Richard Lee, Darren Littlefair, Dale Howes
{"title":"Accuracy of complete-arch implant positions recorded by analog impressions, intraoral scanning, and extraoral and intraoral photogrammetry.","authors":"Richard Lee, Darren Littlefair, Dale Howes","doi":"10.1111/jopr.70249","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this in vitro study was to compare the accuracy of analog impressions, intraoral scanning, extraoral photogrammetry, and intraoral photogrammetry in recording complete-arch implant positions.</p><p><strong>Materials and methods: </strong>A stainless-steel reference model representing an edentulous maxilla with six parallel implants and multiunit abutments was tested using two analog impression techniques; seven intraoral scanners with vertical scan bodies: Omnicam, Primescan, Trios 3, Trios 4, Trios 5, i700, and Aoralscan 3; three extraoral photogrammetry systems: PIC, iCam4D, and Tupel 3D; and one intraoral photogrammetry system: Aoralscan Elite (n = 10 per group). A coordinate-measuring machine measured the abutment center positions and axes on the reference model and analog stone casts, and a computer-aided design program measured the intraoral scanning and photogrammetry digital files. The inter-abutment distances and angles were compared to determine the accuracy of each technique.</p><p><strong>Results: </strong>The analog groups recorded linear trueness of 39-47 µm (precision 17-18 µm) and angular trueness of 0.07°-0.08° (precision 0.02°-0.05°). The intraoral scanning groups recorded linear trueness of 78-141 µm (precision 18-83 µm) and angular trueness of 0.23°-0.71° (precision 0.05°-0.24°). The extraoral photogrammetry groups recorded linear trueness of 53-77 µm (precision 2-30 µm) and angular trueness of 0.22°-0.57° (precision 0.01°-0.05°). The intraoral photogrammetry recorded linear trueness of 15 µm (precision 6 µm) and angular trueness of 0.11° (precision 0.02°).</p><p><strong>Conclusions: </strong>Intraoral scanning demonstrated deviations (mean 101 µm) over twice that of analog impressions (mean 43 µm), while extraoral photogrammetry (mean 62 µm) and intraoral photogrammetry (mean 15 µm) demonstrated accuracy comparable or superior to analog impressions.</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":" ","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2026-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.70249","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The purpose of this in vitro study was to compare the accuracy of analog impressions, intraoral scanning, extraoral photogrammetry, and intraoral photogrammetry in recording complete-arch implant positions.

Materials and methods: A stainless-steel reference model representing an edentulous maxilla with six parallel implants and multiunit abutments was tested using two analog impression techniques; seven intraoral scanners with vertical scan bodies: Omnicam, Primescan, Trios 3, Trios 4, Trios 5, i700, and Aoralscan 3; three extraoral photogrammetry systems: PIC, iCam4D, and Tupel 3D; and one intraoral photogrammetry system: Aoralscan Elite (n = 10 per group). A coordinate-measuring machine measured the abutment center positions and axes on the reference model and analog stone casts, and a computer-aided design program measured the intraoral scanning and photogrammetry digital files. The inter-abutment distances and angles were compared to determine the accuracy of each technique.

Results: The analog groups recorded linear trueness of 39-47 µm (precision 17-18 µm) and angular trueness of 0.07°-0.08° (precision 0.02°-0.05°). The intraoral scanning groups recorded linear trueness of 78-141 µm (precision 18-83 µm) and angular trueness of 0.23°-0.71° (precision 0.05°-0.24°). The extraoral photogrammetry groups recorded linear trueness of 53-77 µm (precision 2-30 µm) and angular trueness of 0.22°-0.57° (precision 0.01°-0.05°). The intraoral photogrammetry recorded linear trueness of 15 µm (precision 6 µm) and angular trueness of 0.11° (precision 0.02°).

Conclusions: Intraoral scanning demonstrated deviations (mean 101 µm) over twice that of analog impressions (mean 43 µm), while extraoral photogrammetry (mean 62 µm) and intraoral photogrammetry (mean 15 µm) demonstrated accuracy comparable or superior to analog impressions.

通过模拟印模、口内扫描、口外和口内摄影测量记录全弓种植体位置的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.90
自引率
15.00%
发文量
171
审稿时长
6-12 weeks
期刊介绍: The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书