Awake versus deep airway device removal in pediatric tonsillectomy: a systematic review and meta-analysis.

IF 1.9
Henrique Baggio Pivetta, Alice O Almeida, Rafael L Miranda, Rafaela P Silva, Raphaela G Mendes, João M M Borges, Raquel E Saldanha, Matheus Arraes, Pablo P Sanín, Walid Alrayashi
{"title":"Awake versus deep airway device removal in pediatric tonsillectomy: a systematic review and meta-analysis.","authors":"Henrique Baggio Pivetta, Alice O Almeida, Rafael L Miranda, Rafaela P Silva, Raphaela G Mendes, João M M Borges, Raquel E Saldanha, Matheus Arraes, Pablo P Sanín, Walid Alrayashi","doi":"10.1016/j.bjane.2026.844840","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>Tonsillectomy, with or without adenoidectomy, is among the most common pediatric surgeries, associated with a high incidence of perioperative respiratory adverse events. The timing of airway device removal, during deep anesthesia or after awakening, may influence these outcomes.</p><p><strong>Methods: </strong>PubMed, Embase and CENTRAL were systematically searched for studies comparing awake and deep airway device removal in pediatric otolaryngology surgery. The primary analysis was restricted to Randomized Controlled Trials (RCTs). The primary outcome was laryngospasm; secondary outcomes included cough, oxygen desaturation and airway obstruction. Risk Ratios (RR) with 95% Confidence Intervals (95% CI) were pooled using random-effects models.</p><p><strong>Results: </strong>Seven studies (six RCTs and one observational study, the latter used only in sensitivity analyses), including 1,571 children, were analyzed. Deep airway device removal was associated with a higher risk of airway obstruction (RR = 1.82; 95% CI 1.10-3.03; p = 0.020) and a lower risk of cough (RR = 0.57; 95% CI 0.43-0.75; p < 0.001), with no evidence of a difference between the Laryngeal Mask Airway (LMA) and Endotracheal Tube (ETT) subgroups (p for subgroup differences = 0.992). Laryngospasm did not differ significantly (RR = 0.99; 95% CI 0.43-2.30; p = 0.984). Desaturation was lower with deep removal in the RCT-only analysis (RR = 0.62; 95% CI 0.44-0.88; p = 0.007).</p><p><strong>Conclusions: </strong>Deep airway device removal was associated with less coughing, with no evidence that this effect differed between LMA and ETT. Deep removal may increase airway obstruction, though sensitive to individual studies. Desaturation findings were sensitive to study design and sare not definitive.</p>","PeriodicalId":72456,"journal":{"name":"Brazilian journal of anesthesiology (Elsevier)","volume":" ","pages":"844840"},"PeriodicalIF":1.9000,"publicationDate":"2026-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian journal of anesthesiology (Elsevier)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.bjane.2026.844840","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objectives: Tonsillectomy, with or without adenoidectomy, is among the most common pediatric surgeries, associated with a high incidence of perioperative respiratory adverse events. The timing of airway device removal, during deep anesthesia or after awakening, may influence these outcomes.

Methods: PubMed, Embase and CENTRAL were systematically searched for studies comparing awake and deep airway device removal in pediatric otolaryngology surgery. The primary analysis was restricted to Randomized Controlled Trials (RCTs). The primary outcome was laryngospasm; secondary outcomes included cough, oxygen desaturation and airway obstruction. Risk Ratios (RR) with 95% Confidence Intervals (95% CI) were pooled using random-effects models.

Results: Seven studies (six RCTs and one observational study, the latter used only in sensitivity analyses), including 1,571 children, were analyzed. Deep airway device removal was associated with a higher risk of airway obstruction (RR = 1.82; 95% CI 1.10-3.03; p = 0.020) and a lower risk of cough (RR = 0.57; 95% CI 0.43-0.75; p < 0.001), with no evidence of a difference between the Laryngeal Mask Airway (LMA) and Endotracheal Tube (ETT) subgroups (p for subgroup differences = 0.992). Laryngospasm did not differ significantly (RR = 0.99; 95% CI 0.43-2.30; p = 0.984). Desaturation was lower with deep removal in the RCT-only analysis (RR = 0.62; 95% CI 0.44-0.88; p = 0.007).

Conclusions: Deep airway device removal was associated with less coughing, with no evidence that this effect differed between LMA and ETT. Deep removal may increase airway obstruction, though sensitive to individual studies. Desaturation findings were sensitive to study design and sare not definitive.

在儿童扁桃体切除术中清醒与深度气道装置移除:系统回顾和荟萃分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书