Smooth total variation regularization for interference detection and elimination (STRIDE) for MRI.

IF 3.1 3区 医学 Q2 ENGINEERING, BIOMEDICAL
Alexander Mertens, Diego Martinez, Amgad Louka, Ying Yang, Chad Harris, Ian Connell
{"title":"Smooth total variation regularization for interference detection and elimination (STRIDE) for MRI.","authors":"Alexander Mertens, Diego Martinez, Amgad Louka, Ying Yang, Chad Harris, Ian Connell","doi":"10.1088/1361-6560/aeb29e","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>Magnetic resonance imaging (MRI) is increasingly required to operate near electronic devices that emit dynamic electromagnetic interference (EMI). Existing reference-channel EMI removal methods estimate a transfer function between EMI sensors and imaging coils from the measured data alone, and do not use prior knowledge about the structure of MR images. We develop and validate an EMI removal method that uses the inherent spatial smoothness of MR images as an additional prior, demonstrated on a head-only 0.5 T scanner.<i>Approach.</i>Smooth total variation regularization for interference detection and elimination (STRIDE) operates in the image domain. For each image column, EMI sensor data are combined and subtracted from the imaging coil data such that the2 norm of the total variation (TV) along the readout direction is minimized. This exploits the smoothness of MR images, a property well-known in compressed sensing but not previously used in EMI removal. STRIDE was evaluated on phantom and<i>in-vivo</i>brain datasets under EMI scenarios replicating sources encountered at our affiliated hospitals, and compared against two implementations of External Dynamic Interference Estimation and Removal (EDITER).<i>Main results.</i>STRIDE produced visually better EMI removal and generally higher temporal signal-to-noise ratio than both EDITER implementations, with comparable EMI removal percentage. STRIDE also resulted in lower or equal root-mean-square error than both EDITER implementations in all 8 phantom EMI conditions tested. These results held across both phantom and<i>in-vivo</i>datasets.<i>Significance.</i>STRIDE shows that incorporating known properties of MR images into the EMI removal problem provides meaningful improvements over methods that rely on measured data alone. The approach is deterministic, training-free, sequence-independent, and compatible with existing EMI sensor hardware. STRIDE therefore extends reference-channel EMI removal to scenarios where existing methods fail, particularly point-of-care and interventional MRI outside fully shielded environments, providing a deterministic, training-free alternative to machine-learning approaches.</p>","PeriodicalId":20185,"journal":{"name":"Physics in medicine and biology","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2026-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in medicine and biology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6560/aeb29e","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective.Magnetic resonance imaging (MRI) is increasingly required to operate near electronic devices that emit dynamic electromagnetic interference (EMI). Existing reference-channel EMI removal methods estimate a transfer function between EMI sensors and imaging coils from the measured data alone, and do not use prior knowledge about the structure of MR images. We develop and validate an EMI removal method that uses the inherent spatial smoothness of MR images as an additional prior, demonstrated on a head-only 0.5 T scanner.Approach.Smooth total variation regularization for interference detection and elimination (STRIDE) operates in the image domain. For each image column, EMI sensor data are combined and subtracted from the imaging coil data such that the2 norm of the total variation (TV) along the readout direction is minimized. This exploits the smoothness of MR images, a property well-known in compressed sensing but not previously used in EMI removal. STRIDE was evaluated on phantom andin-vivobrain datasets under EMI scenarios replicating sources encountered at our affiliated hospitals, and compared against two implementations of External Dynamic Interference Estimation and Removal (EDITER).Main results.STRIDE produced visually better EMI removal and generally higher temporal signal-to-noise ratio than both EDITER implementations, with comparable EMI removal percentage. STRIDE also resulted in lower or equal root-mean-square error than both EDITER implementations in all 8 phantom EMI conditions tested. These results held across both phantom andin-vivodatasets.Significance.STRIDE shows that incorporating known properties of MR images into the EMI removal problem provides meaningful improvements over methods that rely on measured data alone. The approach is deterministic, training-free, sequence-independent, and compatible with existing EMI sensor hardware. STRIDE therefore extends reference-channel EMI removal to scenarios where existing methods fail, particularly point-of-care and interventional MRI outside fully shielded environments, providing a deterministic, training-free alternative to machine-learning approaches.

MRI干涉检测和消除的平滑全变分正则化(STRIDE)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Physics in medicine and biology
Physics in medicine and biology 医学-工程:生物医学
CiteScore
6.50
自引率
14.30%
发文量
409
审稿时长
2 months
期刊介绍: The development and application of theoretical, computational and experimental physics to medicine, physiology and biology. Topics covered are: therapy physics (including ionizing and non-ionizing radiation); biomedical imaging (e.g. x-ray, magnetic resonance, ultrasound, optical and nuclear imaging); image-guided interventions; image reconstruction and analysis (including kinetic modelling); artificial intelligence in biomedical physics and analysis; nanoparticles in imaging and therapy; radiobiology; radiation protection and patient dose monitoring; radiation dosimetry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书