Artificial Intelligence Echocardiographic Interpretation in the Emergency Department: Agreement, Interpretation Yield and Reporting Scope.

IF 1.5 4区 医学 Q2 EMERGENCY MEDICINE
Vijay Manivel, Michael Hession, Behzad Mirmiran, Patrick Feeny, Nadi Pandithage, Nasim Erfani, Riaz Humayun, Steven Beatty
{"title":"Artificial Intelligence Echocardiographic Interpretation in the Emergency Department: Agreement, Interpretation Yield and Reporting Scope.","authors":"Vijay Manivel, Michael Hession, Behzad Mirmiran, Patrick Feeny, Nadi Pandithage, Nasim Erfani, Riaz Humayun, Steven Beatty","doi":"10.1111/1742-6723.70364","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To assess the agreement between artificial intelligence (AI) interpretation and expert emergency physician sonologist review of echocardiograms performed in the Emergency Department (ED).</p><p><strong>Methods: </strong>Retrospective multicentre agreement study in four Australian EDs. A total of 195 echocardiograms (2016-2023) underwent three-stage adjudicated human expert review. Human reports were compared with us2.ai reports. Agreement across 10 validated parameters was reported as percentage exact match with 95% confidence intervals and kappa under two pre-specified tiers: Guideline Compliant (GC; ASE/EACVI multi-view criteria) and Pragmatic (PR; any available measurement). Reference standard reliability was quantified.</p><p><strong>Results: </strong>Pooled agreement was 76% at both tiers (GC n = 875; PR n = 1323); AI returned an interpretation in 46% of evaluations at GC and 70% at PR. Four structural parameters reached 78%-87%: right atrial size 87% (κ = 0.62), right ventricular (RV) contractility 83% (κ = 0.42), left ventricular (LV) size 83% (κ = 0.52) and RV size 78% (κ = 0.37). Binary LV systolic agreement was 79% GC and 83% PR. Expert reviewers agreed on 85% of interpretations. Pericardial effusion, aortic regurgitation and mitral stenosis, present in 7%-20% of patients, are not reported in the current us2.ai algorithm.</p><p><strong>Conclusion: </strong>AI agreed with expert review in about three-quarters of evaluations but provided a guideline-compliant interpretation in less than half; a pragmatic approach raised yield to 70% at the same agreement. The AI withheld classifications that experts could reach; its validated scope covers only part of what ED echocardiography must address, and reports did not mark unassessed parameters. This study reports agreement, not accuracy. For now, human expert review of AI reports is required.</p>","PeriodicalId":11604,"journal":{"name":"Emergency Medicine Australasia","volume":"38 5","pages":"e70364"},"PeriodicalIF":1.5000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13653218/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Emergency Medicine Australasia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/1742-6723.70364","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To assess the agreement between artificial intelligence (AI) interpretation and expert emergency physician sonologist review of echocardiograms performed in the Emergency Department (ED).

Methods: Retrospective multicentre agreement study in four Australian EDs. A total of 195 echocardiograms (2016-2023) underwent three-stage adjudicated human expert review. Human reports were compared with us2.ai reports. Agreement across 10 validated parameters was reported as percentage exact match with 95% confidence intervals and kappa under two pre-specified tiers: Guideline Compliant (GC; ASE/EACVI multi-view criteria) and Pragmatic (PR; any available measurement). Reference standard reliability was quantified.

Results: Pooled agreement was 76% at both tiers (GC n = 875; PR n = 1323); AI returned an interpretation in 46% of evaluations at GC and 70% at PR. Four structural parameters reached 78%-87%: right atrial size 87% (κ = 0.62), right ventricular (RV) contractility 83% (κ = 0.42), left ventricular (LV) size 83% (κ = 0.52) and RV size 78% (κ = 0.37). Binary LV systolic agreement was 79% GC and 83% PR. Expert reviewers agreed on 85% of interpretations. Pericardial effusion, aortic regurgitation and mitral stenosis, present in 7%-20% of patients, are not reported in the current us2.ai algorithm.

Conclusion: AI agreed with expert review in about three-quarters of evaluations but provided a guideline-compliant interpretation in less than half; a pragmatic approach raised yield to 70% at the same agreement. The AI withheld classifications that experts could reach; its validated scope covers only part of what ED echocardiography must address, and reports did not mark unassessed parameters. This study reports agreement, not accuracy. For now, human expert review of AI reports is required.

急诊人工智能超声心动图解读:共识、解读率和报告范围。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Emergency Medicine Australasia
Emergency Medicine Australasia 医学-急救医学
CiteScore
3.70
自引率
13.00%
发文量
217
审稿时长
6-12 weeks
期刊介绍: Emergency Medicine Australasia is the official journal of the Australasian College for Emergency Medicine (ACEM) and the Australasian Society for Emergency Medicine (ASEM), and publishes original articles dealing with all aspects of clinical practice, research, education and experiences in emergency medicine. Original articles are published under the following sections: Original Research, Paediatric Emergency Medicine, Disaster Medicine, Education and Training, Ethics, International Emergency Medicine, Management and Quality, Medicolegal Matters, Prehospital Care, Public Health, Rural and Remote Care, Technology, Toxicology and Trauma. Accepted papers become the copyright of the journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书