Proton-density fat-saturated non-contrast MR imaging is comparable to post-contrast MR imaging for revealing wrist synovitis.

IF 5.6 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Su Wu, James Francis Griffith, João Dourado, Lai Shan Tam
{"title":"Proton-density fat-saturated non-contrast MR imaging is comparable to post-contrast MR imaging for revealing wrist synovitis.","authors":"Su Wu, James Francis Griffith, João Dourado, Lai Shan Tam","doi":"10.1186/s13244-026-02406-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Standard MR imaging (MRI) for rheumatoid arthritis (RA) patients comprises a post-contrast T1-fat-saturated (T1FS + C) sequence to detect wrist synovitis and tenosynovitis. This study investigates whether non-contrast sequences can provide similar information to post-contrast imaging.</p><p><strong>Materials and methods: </strong>Seventy-seven RA patients (F/M:  64/13; age: 61 ± 12 years) underwent MRI examination of the most symptomatic wrist on a 3.0-T system. Axial T1FS + C as well as proton-density imaging with fat-saturation (PDFS) and T2-weighted imaging with fat-saturation (T2FS) sequences were performed. Two radiologists independently scored synovitis and tenosynovitis severity on all sequences, using the rheumatoid arthritis magnetic resonance imaging scoring system (RAMRIS). Intra- and interclass correlation coefficients (ICCs) were assessed.</p><p><strong>Results: </strong>For synovitis severity scoring, PDFS was practically identical to T1FS + C, while T2FS overestimated synovitis severity by up to 19%. For synovitis severity, PDFS imaging correlated better with T1FS + C than T2FS imaging (ICC: Reader 1: 0.931 vs 0.897; Reader 2: 0.969 vs 0.948). For tenosynovitis severity, PDFS and T2FS both yielded higher tenosynovitis scores than T1FS + C (p < 0.001). Compared to T1FS + C imaging, PDFS overestimated tenosynovitis severity by up to 39%, while T2FS overestimated tenosynovitis severity by up to 54%. For tenosynovitis severity, PDFS imaging correlated better with T1FS + C than T2FS imaging (ICC: Reader 1: 0.856 vs 0.731; Reader 2: 0.808 vs 0.800).</p><p><strong>Conclusion: </strong>PDFS imaging had good (for tenosynovitis) to excellent (for synovitis) intra- and inter-reader reliability and provides comparable scoring to T1FS + C imaging when evaluating synovitis severity, though it tends to overestimate tenosynovitis severity. PDFS imaging can reasonably replace contrast-enhanced imaging for assessing wrist synovitis in RA patients.</p><p><strong>Key points: </strong>Question Post-contrast imaging is recommended for evaluating synovitis and tenosynovitis in rheumatoid arthritis (RA) patients, though it involves higher cost, scan time, and discomfort. Findings Proton-density imaging with fat-saturation (PDFS) imaging had good to excellent intra- and inter-reader reliability for evaluating synovitis and tenosynovitis in RA wrists. Compared to post-contrast T1-fat-saturated (T1FS + C) imaging, PDFS imaging provides comparable semi-quantitative synovitis severity grading but tends to overestimate tenosynovitis severity. Critical relevance statement Post-contrast imaging for synovitis and tenosynovitis in RA patients involves discomfort, a longer time, and cost. PDFS imaging has good reliability and compares well with post-contrast imaging. In RA wrists, compared to T1FS+C imaging, PDFS imaging provides comparative semi-quantitative synovitis severity grading but tends to overestimate tenosynovitis severity.</p>","PeriodicalId":13639,"journal":{"name":"Insights into Imaging","volume":"17 1","pages":""},"PeriodicalIF":5.6000,"publicationDate":"2026-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13653001/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Insights into Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13244-026-02406-1","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Standard MR imaging (MRI) for rheumatoid arthritis (RA) patients comprises a post-contrast T1-fat-saturated (T1FS + C) sequence to detect wrist synovitis and tenosynovitis. This study investigates whether non-contrast sequences can provide similar information to post-contrast imaging.

Materials and methods: Seventy-seven RA patients (F/M:  64/13; age: 61 ± 12 years) underwent MRI examination of the most symptomatic wrist on a 3.0-T system. Axial T1FS + C as well as proton-density imaging with fat-saturation (PDFS) and T2-weighted imaging with fat-saturation (T2FS) sequences were performed. Two radiologists independently scored synovitis and tenosynovitis severity on all sequences, using the rheumatoid arthritis magnetic resonance imaging scoring system (RAMRIS). Intra- and interclass correlation coefficients (ICCs) were assessed.

Results: For synovitis severity scoring, PDFS was practically identical to T1FS + C, while T2FS overestimated synovitis severity by up to 19%. For synovitis severity, PDFS imaging correlated better with T1FS + C than T2FS imaging (ICC: Reader 1: 0.931 vs 0.897; Reader 2: 0.969 vs 0.948). For tenosynovitis severity, PDFS and T2FS both yielded higher tenosynovitis scores than T1FS + C (p < 0.001). Compared to T1FS + C imaging, PDFS overestimated tenosynovitis severity by up to 39%, while T2FS overestimated tenosynovitis severity by up to 54%. For tenosynovitis severity, PDFS imaging correlated better with T1FS + C than T2FS imaging (ICC: Reader 1: 0.856 vs 0.731; Reader 2: 0.808 vs 0.800).

Conclusion: PDFS imaging had good (for tenosynovitis) to excellent (for synovitis) intra- and inter-reader reliability and provides comparable scoring to T1FS + C imaging when evaluating synovitis severity, though it tends to overestimate tenosynovitis severity. PDFS imaging can reasonably replace contrast-enhanced imaging for assessing wrist synovitis in RA patients.

Key points: Question Post-contrast imaging is recommended for evaluating synovitis and tenosynovitis in rheumatoid arthritis (RA) patients, though it involves higher cost, scan time, and discomfort. Findings Proton-density imaging with fat-saturation (PDFS) imaging had good to excellent intra- and inter-reader reliability for evaluating synovitis and tenosynovitis in RA wrists. Compared to post-contrast T1-fat-saturated (T1FS + C) imaging, PDFS imaging provides comparable semi-quantitative synovitis severity grading but tends to overestimate tenosynovitis severity. Critical relevance statement Post-contrast imaging for synovitis and tenosynovitis in RA patients involves discomfort, a longer time, and cost. PDFS imaging has good reliability and compares well with post-contrast imaging. In RA wrists, compared to T1FS+C imaging, PDFS imaging provides comparative semi-quantitative synovitis severity grading but tends to overestimate tenosynovitis severity.

质子密度饱和脂肪非对比磁共振成像与对比后磁共振成像在显示手腕滑膜炎方面相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Insights into Imaging
Insights into Imaging Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
7.30
自引率
4.30%
发文量
182
审稿时长
13 weeks
期刊介绍: Insights into Imaging (I³) is a peer-reviewed open access journal published under the brand SpringerOpen. All content published in the journal is freely available online to anyone, anywhere! I³ continuously updates scientific knowledge and progress in best-practice standards in radiology through the publication of original articles and state-of-the-art reviews and opinions, along with recommendations and statements from the leading radiological societies in Europe. Founded by the European Society of Radiology (ESR), I³ creates a platform for educational material, guidelines and recommendations, and a forum for topics of controversy. A balanced combination of review articles, original papers, short communications from European radiological congresses and information on society matters makes I³ an indispensable source for current information in this field. I³ is owned by the ESR, however authors retain copyright to their article according to the Creative Commons Attribution License (see Copyright and License Agreement). All articles can be read, redistributed and reused for free, as long as the author of the original work is cited properly. The open access fees (article-processing charges) for this journal are kindly sponsored by ESR for all Members. The journal went open access in 2012, which means that all articles published since then are freely available online.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书