Roadmap to Fully Closing the Loop to Optimize Health in Type 1 Diabetes.

IF 7.4 2区 医学 Q1 ENDOCRINOLOGY & METABOLISM
Brynn E Marks, Marisa E Hilliard, Boris Kovatchev, Othmar Moser, Molly L Tanenbaum, Courtney Ackeifi, David T Ahn, Ramzi A Ajjan, Anastasia Albanese-O'Neill, Abdulmohsen Bakhsh, Pratik Choudhary, Kelly L Close, Elizabeth A Davis, Klemen Dovc, Sanjoy Dutta, Satish Garg, Gregory P Forlenza, Julie Heverly, Aaron J Kowalski, Catarina Limbert, David M Maahs, Julia K Mader, Marjana Marinac, Chantal Mathieu, Revital Nimri, Rimei Nishimura, David N O'Neal, Monica Oxenreiter, Chengyuan Press, Michael R Rickels, Michael C Riddell, Jonathan Rosen, Banshi Saboo, Viral N Shah, Jennifer L Sherr, Benjamin J Wheeler, Moshe Phillip, Tadej Battelino, Thomas Danne
{"title":"Roadmap to Fully Closing the Loop to Optimize Health in Type 1 Diabetes.","authors":"Brynn E Marks, Marisa E Hilliard, Boris Kovatchev, Othmar Moser, Molly L Tanenbaum, Courtney Ackeifi, David T Ahn, Ramzi A Ajjan, Anastasia Albanese-O'Neill, Abdulmohsen Bakhsh, Pratik Choudhary, Kelly L Close, Elizabeth A Davis, Klemen Dovc, Sanjoy Dutta, Satish Garg, Gregory P Forlenza, Julie Heverly, Aaron J Kowalski, Catarina Limbert, David M Maahs, Julia K Mader, Marjana Marinac, Chantal Mathieu, Revital Nimri, Rimei Nishimura, David N O'Neal, Monica Oxenreiter, Chengyuan Press, Michael R Rickels, Michael C Riddell, Jonathan Rosen, Banshi Saboo, Viral N Shah, Jennifer L Sherr, Benjamin J Wheeler, Moshe Phillip, Tadej Battelino, Thomas Danne","doi":"10.1177/15209156261496643","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Current commercially available automated insulin delivery systems require meal and exercise announcements for optimal function, placing them in the hybrid closed loop category. Ongoing advancements aim to establish fully closed loop (FCL) systems as the next-generation standard for type 1 diabetes (T1D) management, eliminating the need for such inputs. We sought to develop a shared definition of FCL so that emerging technologies, including those using artificial intelligence, multi-hormone delivery, multi-analyte sensing, and/or adjunctive therapies, are held to uniform performance standards.</p><p><strong>Methods: </strong>A group of invited experts, including clinicians, researchers, and people with lived experience convened to propose an outcome-driven definition of FCL systems.</p><p><strong>Results: </strong>FCL systems are defined by three core domains centered on meeting intensive glycemic targets while reducing self-management burden and improving lived experience: Time in Tight Range (TITR) 70-140 mg/dL (3.9-7.8 mmol/L), Time Below Range (TBR) <54 mg/dL (<3.0 mmol/L), and person-reported outcomes (PROs) measured with validated T1D-specific assessments. This definition rests on a three-tiered classification in which all FCL systems improve lived experience and attain >50% TITR and <1% TBR without mandatory meal or activity announcements. Class 3 systems must attain >50% TITR; Class 2, >70%; and Class 1, >90%-while simultaneously demonstrating improved quality of life and reduced treatment burden per validated PROs. Given the elevated hypoglycemia risk from insulin-on-board during exercise, Class 1a requires >90% TITR with demonstrable hypoglycemia prevention during standardized exercise testing (0% TBR).</p><p><strong>Conclusion: </strong>This framework provides a uniform benchmark for evaluating future FCL technologies. Taken together, this person-centered, outcome-driven framework holds that FCL systems should (1) autonomously attain near-normoglycemia, (2) meaningfully improve lived experience across the lifespan and clinical contexts, and (3) prevent exercise-related hypoglycemia.</p>","PeriodicalId":11159,"journal":{"name":"Diabetes technology & therapeutics","volume":" ","pages":"15209156261496643"},"PeriodicalIF":7.4000,"publicationDate":"2026-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes technology & therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15209156261496643","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Current commercially available automated insulin delivery systems require meal and exercise announcements for optimal function, placing them in the hybrid closed loop category. Ongoing advancements aim to establish fully closed loop (FCL) systems as the next-generation standard for type 1 diabetes (T1D) management, eliminating the need for such inputs. We sought to develop a shared definition of FCL so that emerging technologies, including those using artificial intelligence, multi-hormone delivery, multi-analyte sensing, and/or adjunctive therapies, are held to uniform performance standards.

Methods: A group of invited experts, including clinicians, researchers, and people with lived experience convened to propose an outcome-driven definition of FCL systems.

Results: FCL systems are defined by three core domains centered on meeting intensive glycemic targets while reducing self-management burden and improving lived experience: Time in Tight Range (TITR) 70-140 mg/dL (3.9-7.8 mmol/L), Time Below Range (TBR) <54 mg/dL (<3.0 mmol/L), and person-reported outcomes (PROs) measured with validated T1D-specific assessments. This definition rests on a three-tiered classification in which all FCL systems improve lived experience and attain >50% TITR and <1% TBR without mandatory meal or activity announcements. Class 3 systems must attain >50% TITR; Class 2, >70%; and Class 1, >90%-while simultaneously demonstrating improved quality of life and reduced treatment burden per validated PROs. Given the elevated hypoglycemia risk from insulin-on-board during exercise, Class 1a requires >90% TITR with demonstrable hypoglycemia prevention during standardized exercise testing (0% TBR).

Conclusion: This framework provides a uniform benchmark for evaluating future FCL technologies. Taken together, this person-centered, outcome-driven framework holds that FCL systems should (1) autonomously attain near-normoglycemia, (2) meaningfully improve lived experience across the lifespan and clinical contexts, and (3) prevent exercise-related hypoglycemia.

全面闭环优化1型糖尿病患者健康的路线图
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Diabetes technology & therapeutics
Diabetes technology & therapeutics 医学-内分泌学与代谢
CiteScore
10.60
自引率
14.80%
发文量
145
审稿时长
3-8 weeks
期刊介绍: Diabetes Technology & Therapeutics is the only peer-reviewed journal providing healthcare professionals with information on new devices, drugs, drug delivery systems, and software for managing patients with diabetes. This leading international journal delivers practical information and comprehensive coverage of cutting-edge technologies and therapeutics in the field, and each issue highlights new pharmacological and device developments to optimize patient care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书