Brynn E Marks, Marisa E Hilliard, Boris Kovatchev, Othmar Moser, Molly L Tanenbaum, Courtney Ackeifi, David T Ahn, Ramzi A Ajjan, Anastasia Albanese-O'Neill, Abdulmohsen Bakhsh, Pratik Choudhary, Kelly L Close, Elizabeth A Davis, Klemen Dovc, Sanjoy Dutta, Satish Garg, Gregory P Forlenza, Julie Heverly, Aaron J Kowalski, Catarina Limbert, David M Maahs, Julia K Mader, Marjana Marinac, Chantal Mathieu, Revital Nimri, Rimei Nishimura, David N O'Neal, Monica Oxenreiter, Chengyuan Press, Michael R Rickels, Michael C Riddell, Jonathan Rosen, Banshi Saboo, Viral N Shah, Jennifer L Sherr, Benjamin J Wheeler, Moshe Phillip, Tadej Battelino, Thomas Danne
{"title":"Roadmap to Fully Closing the Loop to Optimize Health in Type 1 Diabetes.","authors":"Brynn E Marks, Marisa E Hilliard, Boris Kovatchev, Othmar Moser, Molly L Tanenbaum, Courtney Ackeifi, David T Ahn, Ramzi A Ajjan, Anastasia Albanese-O'Neill, Abdulmohsen Bakhsh, Pratik Choudhary, Kelly L Close, Elizabeth A Davis, Klemen Dovc, Sanjoy Dutta, Satish Garg, Gregory P Forlenza, Julie Heverly, Aaron J Kowalski, Catarina Limbert, David M Maahs, Julia K Mader, Marjana Marinac, Chantal Mathieu, Revital Nimri, Rimei Nishimura, David N O'Neal, Monica Oxenreiter, Chengyuan Press, Michael R Rickels, Michael C Riddell, Jonathan Rosen, Banshi Saboo, Viral N Shah, Jennifer L Sherr, Benjamin J Wheeler, Moshe Phillip, Tadej Battelino, Thomas Danne","doi":"10.1177/15209156261496643","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Current commercially available automated insulin delivery systems require meal and exercise announcements for optimal function, placing them in the hybrid closed loop category. Ongoing advancements aim to establish fully closed loop (FCL) systems as the next-generation standard for type 1 diabetes (T1D) management, eliminating the need for such inputs. We sought to develop a shared definition of FCL so that emerging technologies, including those using artificial intelligence, multi-hormone delivery, multi-analyte sensing, and/or adjunctive therapies, are held to uniform performance standards.</p><p><strong>Methods: </strong>A group of invited experts, including clinicians, researchers, and people with lived experience convened to propose an outcome-driven definition of FCL systems.</p><p><strong>Results: </strong>FCL systems are defined by three core domains centered on meeting intensive glycemic targets while reducing self-management burden and improving lived experience: Time in Tight Range (TITR) 70-140 mg/dL (3.9-7.8 mmol/L), Time Below Range (TBR) <54 mg/dL (<3.0 mmol/L), and person-reported outcomes (PROs) measured with validated T1D-specific assessments. This definition rests on a three-tiered classification in which all FCL systems improve lived experience and attain >50% TITR and <1% TBR without mandatory meal or activity announcements. Class 3 systems must attain >50% TITR; Class 2, >70%; and Class 1, >90%-while simultaneously demonstrating improved quality of life and reduced treatment burden per validated PROs. Given the elevated hypoglycemia risk from insulin-on-board during exercise, Class 1a requires >90% TITR with demonstrable hypoglycemia prevention during standardized exercise testing (0% TBR).</p><p><strong>Conclusion: </strong>This framework provides a uniform benchmark for evaluating future FCL technologies. Taken together, this person-centered, outcome-driven framework holds that FCL systems should (1) autonomously attain near-normoglycemia, (2) meaningfully improve lived experience across the lifespan and clinical contexts, and (3) prevent exercise-related hypoglycemia.</p>","PeriodicalId":11159,"journal":{"name":"Diabetes technology & therapeutics","volume":" ","pages":"15209156261496643"},"PeriodicalIF":7.4000,"publicationDate":"2026-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes technology & therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15209156261496643","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Current commercially available automated insulin delivery systems require meal and exercise announcements for optimal function, placing them in the hybrid closed loop category. Ongoing advancements aim to establish fully closed loop (FCL) systems as the next-generation standard for type 1 diabetes (T1D) management, eliminating the need for such inputs. We sought to develop a shared definition of FCL so that emerging technologies, including those using artificial intelligence, multi-hormone delivery, multi-analyte sensing, and/or adjunctive therapies, are held to uniform performance standards.
Methods: A group of invited experts, including clinicians, researchers, and people with lived experience convened to propose an outcome-driven definition of FCL systems.
Results: FCL systems are defined by three core domains centered on meeting intensive glycemic targets while reducing self-management burden and improving lived experience: Time in Tight Range (TITR) 70-140 mg/dL (3.9-7.8 mmol/L), Time Below Range (TBR) <54 mg/dL (<3.0 mmol/L), and person-reported outcomes (PROs) measured with validated T1D-specific assessments. This definition rests on a three-tiered classification in which all FCL systems improve lived experience and attain >50% TITR and <1% TBR without mandatory meal or activity announcements. Class 3 systems must attain >50% TITR; Class 2, >70%; and Class 1, >90%-while simultaneously demonstrating improved quality of life and reduced treatment burden per validated PROs. Given the elevated hypoglycemia risk from insulin-on-board during exercise, Class 1a requires >90% TITR with demonstrable hypoglycemia prevention during standardized exercise testing (0% TBR).
Conclusion: This framework provides a uniform benchmark for evaluating future FCL technologies. Taken together, this person-centered, outcome-driven framework holds that FCL systems should (1) autonomously attain near-normoglycemia, (2) meaningfully improve lived experience across the lifespan and clinical contexts, and (3) prevent exercise-related hypoglycemia.
期刊介绍:
Diabetes Technology & Therapeutics is the only peer-reviewed journal providing healthcare professionals with information on new devices, drugs, drug delivery systems, and software for managing patients with diabetes. This leading international journal delivers practical information and comprehensive coverage of cutting-edge technologies and therapeutics in the field, and each issue highlights new pharmacological and device developments to optimize patient care.