{"title":"Similarity-Aware Evaluation, Probability Calibration, and Independent Replication for Reliable Gastrointestinal Image Classification","authors":"Housheng Liu,&nbsp;Yingwu Xu,&nbsp;Fang Cheng,&nbsp;Jinlian Zha","doi":"10.1002/ima.70452","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>High accuracy alone does not establish reliable medical-image classification because visually similar images may cross partitions and confidence may be miscalibrated. We evaluated a similarity-aware framework on a four-class gastrointestinal benchmark (4000 images) and independently replicated the methodology on GastroVision (8000 images; 27 classes). A 64-bit DCT perceptual hash defined groups at Hamming distance ≤ 4. Five-fold random and group-constrained protocols were matched by model and seed, with separate validation, calibration, and test subsets. We compared modern backbones, temperature scaling, a 2 × 2 Mixup/label-smoothing ablation, and deterministic maximum-softmax probability. On the primary benchmark, grouped EfficientNet-B0 achieved accuracy and macro-F1 of 0.9765 ± 0.0022. Grouping changed accuracy by +0.0025 relative to random splitting (Wilcoxon <i>p</i> = 0.625). Temperature scaling reduced expected calibration error from 0.1292 ± 0.0216 to 0.0123 ± 0.0030 without changing predictions, and deterministic MSP achieved error-detection AUROC of 0.9288 ± 0.0181. On GastroVision, random folds contained 78–101 detected cross-subset overlaps, whereas grouped folds contained none. Grouped EfficientNet-B0 achieved 0.8195 ± 0.0043 accuracy and 0.5792 ± 0.0148 macro-F1; ECE decreased from 0.1114 ± 0.0148 to 0.0323 ± 0.0048 after scaling. Similarity grouping removed detected resemblance without reducing accuracy, while calibration and uncertainty analyses exposed properties hidden by discrimination metrics. GastroVision supports methodological portability rather than direct external validation; pHash cannot establish patient or procedure independence, for which identifiers remain preferable.</p>\n </div>","PeriodicalId":14027,"journal":{"name":"International Journal of Imaging Systems and Technology","volume":"36 6","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2026-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Imaging Systems and Technology","FirstCategoryId":"94","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ima.70452","RegionNum":4,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

High accuracy alone does not establish reliable medical-image classification because visually similar images may cross partitions and confidence may be miscalibrated. We evaluated a similarity-aware framework on a four-class gastrointestinal benchmark (4000 images) and independently replicated the methodology on GastroVision (8000 images; 27 classes). A 64-bit DCT perceptual hash defined groups at Hamming distance ≤ 4. Five-fold random and group-constrained protocols were matched by model and seed, with separate validation, calibration, and test subsets. We compared modern backbones, temperature scaling, a 2 × 2 Mixup/label-smoothing ablation, and deterministic maximum-softmax probability. On the primary benchmark, grouped EfficientNet-B0 achieved accuracy and macro-F1 of 0.9765 ± 0.0022. Grouping changed accuracy by +0.0025 relative to random splitting (Wilcoxon p = 0.625). Temperature scaling reduced expected calibration error from 0.1292 ± 0.0216 to 0.0123 ± 0.0030 without changing predictions, and deterministic MSP achieved error-detection AUROC of 0.9288 ± 0.0181. On GastroVision, random folds contained 78–101 detected cross-subset overlaps, whereas grouped folds contained none. Grouped EfficientNet-B0 achieved 0.8195 ± 0.0043 accuracy and 0.5792 ± 0.0148 macro-F1; ECE decreased from 0.1114 ± 0.0148 to 0.0323 ± 0.0048 after scaling. Similarity grouping removed detected resemblance without reducing accuracy, while calibration and uncertainty analyses exposed properties hidden by discrimination metrics. GastroVision supports methodological portability rather than direct external validation; pHash cannot establish patient or procedure independence, for which identifiers remain preferable.

相似感知评估、概率校准和独立复制用于可靠的胃肠道图像分类
高精确度本身并不能建立可靠的医学图像分类,因为视觉上相似的图像可能会交叉分割,置信度可能会校准错误。我们在四类胃肠基准(4000张图像)上评估了相似性感知框架,并在GastroVision(8000张图像,27个类别)上独立复制了该方法。一个64位DCT感知哈希定义了汉明距离≤4的组。五倍随机和组约束协议通过模型和种子匹配,具有单独的验证、校准和测试子集。我们比较了现代骨干网、温度缩放、2 × 2混合/标签平滑消融和确定性最大软最大概率。在主要基准上,有效率网- b0组的准确率和宏观f1为0.9765±0.0022。与随机分组相比,分组的准确率提高了+0.0025 (Wilcoxon p = 0.625)。在不改变预测值的情况下,温度标度将预期校准误差从0.1292±0.0216降低到0.0123±0.0030,确定性MSP的误差检测AUROC为0.9288±0.0181。在GastroVision上,随机折叠包含78-101个检测到的交叉子集重叠,而分组折叠则没有。分组效率网- b0的准确度为0.8195±0.0043,宏观f1为0.5792±0.0148;除垢后ECE由0.1114±0.0148降至0.0323±0.0048。相似性分组在不降低准确性的情况下去除检测到的相似性,而校准和不确定度分析暴露了由区分度量隐藏的属性。GastroVision支持方法可移植性,而不是直接的外部验证;pHash不能建立患者或程序独立性,因此标识符仍然是首选。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Imaging Systems and Technology
International Journal of Imaging Systems and Technology 工程技术-成像科学与照相技术
CiteScore
6.90
自引率
6.10%
发文量
138
审稿时长
3 months
期刊介绍: The International Journal of Imaging Systems and Technology (IMA) is a forum for the exchange of ideas and results relevant to imaging systems, including imaging physics and informatics. The journal covers all imaging modalities in humans and animals. IMA accepts technically sound and scientifically rigorous research in the interdisciplinary field of imaging, including relevant algorithmic research and hardware and software development, and their applications relevant to medical research. The journal provides a platform to publish original research in structural and functional imaging. The journal is also open to imaging studies of the human body and on animals that describe novel diagnostic imaging and analyses methods. Technical, theoretical, and clinical research in both normal and clinical populations is encouraged. Submissions describing methods, software, databases, replication studies as well as negative results are also considered. The scope of the journal includes, but is not limited to, the following in the context of biomedical research: Imaging and neuro-imaging modalities: structural MRI, functional MRI, PET, SPECT, CT, ultrasound, EEG, MEG, NIRS etc.; Neuromodulation and brain stimulation techniques such as TMS and tDCS; Software and hardware for imaging, especially related to human and animal health; Image segmentation in normal and clinical populations; Pattern analysis and classification using machine learning techniques; Computational modeling and analysis; Brain connectivity and connectomics; Systems-level characterization of brain function; Neural networks and neurorobotics; Computer vision, based on human/animal physiology; Brain-computer interface (BCI) technology; Big data, databasing and data mining.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书