Beyond segmentation accuracy: understanding model reliability and failure modes in ultrasound image analysis.

IF 4.6 Q3 ENGINEERING, BIOMEDICAL
Frontiers in medical technology Pub Date : 2026-09-23 eCollection Date: 2026-01-01 DOI:10.3389/fmedt.2026.1918432
Agathe Bricout, David Hardman, Scott Inglis, Stephen Pye, Carmel M Moran
{"title":"Beyond segmentation accuracy: understanding model reliability and failure modes in ultrasound image analysis.","authors":"Agathe Bricout, David Hardman, Scott Inglis, Stephen Pye, Carmel M Moran","doi":"10.3389/fmedt.2026.1918432","DOIUrl":null,"url":null,"abstract":"<p><p>Segmentation of ultrasound images is complex, and although deep learning has improved automation, trust remains limited, restricting adoption. Interpretability methods may help reveal model behaviours and failure modes, supporting more trustworthy AI systems. A U-Net with a ResNet-18 backbone was trained to segment pipes in images of the Edinburgh Pipe Phantom acquired using ten ultrasound probes (<i>N</i> = 162). Performance was assessed using five-fold cross-validation. Predictive entropy and variance across 20 Monte Carlo dropout forward passes were used as approximations of data-related and model-related uncertainty. Calibration was assessed using the Brier score and expected calibration error (ECE). Input-gradient saliency and Grad-CAM maps from four encoder stages and the final decoder block were evaluated. For exploratory prospective quality control, complete empty-mask failures were assessed directly from model output, while non-empty predictions were classified retrospectively using reference-based performance criteria and reference-free uncertainty and morphological features were evaluated as candidate indicators. The model achieved a Dice score of 0.81 ± 0.03 and an HD95 of 11.98 ± 3.39. Seven segmentation errors were identified: three complete failures in which no foreground mask was predicted and four non-empty predictions in which the incorrect pipe was segmented. Dice score was associated with the Brier score (Spearman <i>ρ</i> = -0.96) and ECE (<i>ρ</i> = -0.72), whereas predictive entropy and Monte Carlo dropout variance showed weak associations with segmentation performance (|<i>ρ</i>| < 0.4). In selected failure examples, uncertainty and activation sometimes overlapped the reference pipe region despite incorrect segmentation. Complete empty-mask failures were deterministically identifiable from the model output, whereas the evaluated reference-free indicators showed limited ability to identify poor-quality non-empty segmentations. Within this phantom dataset and model configuration, calibration metrics were more closely associated with segmentation quality than the evaluated uncertainty approximations. Attention and uncertainty maps provided complementary descriptive information about selected errors, but indicated spatial sensitivity rather than causal model reasoning. Simple output checks enabled deterministic identification of complete segmentation failures; however, the evaluated reference-free indicators were insufficient for validated prospective identification of subtler non-empty errors. These findings support multimodal model evaluation for EPP segmentation while emphasising the need for validation on independent datasets, devices and architectures in future studies.</p>","PeriodicalId":94015,"journal":{"name":"Frontiers in medical technology","volume":"8 ","pages":"1918432"},"PeriodicalIF":4.6000,"publicationDate":"2026-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13642736/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in medical technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fmedt.2026.1918432","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Segmentation of ultrasound images is complex, and although deep learning has improved automation, trust remains limited, restricting adoption. Interpretability methods may help reveal model behaviours and failure modes, supporting more trustworthy AI systems. A U-Net with a ResNet-18 backbone was trained to segment pipes in images of the Edinburgh Pipe Phantom acquired using ten ultrasound probes (N = 162). Performance was assessed using five-fold cross-validation. Predictive entropy and variance across 20 Monte Carlo dropout forward passes were used as approximations of data-related and model-related uncertainty. Calibration was assessed using the Brier score and expected calibration error (ECE). Input-gradient saliency and Grad-CAM maps from four encoder stages and the final decoder block were evaluated. For exploratory prospective quality control, complete empty-mask failures were assessed directly from model output, while non-empty predictions were classified retrospectively using reference-based performance criteria and reference-free uncertainty and morphological features were evaluated as candidate indicators. The model achieved a Dice score of 0.81 ± 0.03 and an HD95 of 11.98 ± 3.39. Seven segmentation errors were identified: three complete failures in which no foreground mask was predicted and four non-empty predictions in which the incorrect pipe was segmented. Dice score was associated with the Brier score (Spearman ρ = -0.96) and ECE (ρ = -0.72), whereas predictive entropy and Monte Carlo dropout variance showed weak associations with segmentation performance (|ρ| < 0.4). In selected failure examples, uncertainty and activation sometimes overlapped the reference pipe region despite incorrect segmentation. Complete empty-mask failures were deterministically identifiable from the model output, whereas the evaluated reference-free indicators showed limited ability to identify poor-quality non-empty segmentations. Within this phantom dataset and model configuration, calibration metrics were more closely associated with segmentation quality than the evaluated uncertainty approximations. Attention and uncertainty maps provided complementary descriptive information about selected errors, but indicated spatial sensitivity rather than causal model reasoning. Simple output checks enabled deterministic identification of complete segmentation failures; however, the evaluated reference-free indicators were insufficient for validated prospective identification of subtler non-empty errors. These findings support multimodal model evaluation for EPP segmentation while emphasising the need for validation on independent datasets, devices and architectures in future studies.

超越分割精度:了解超声图像分析中的模型可靠性和失效模式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.70
自引率
0.00%
发文量
0
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书