Dual Adaptive Grouped Multivariate Variational Mode Decomposition for Physiological Signals.

IF 4.4 2区 医学 Q2 ENGINEERING, BIOMEDICAL
Tian Zhang, Duanpo Wu, Lian Zhang, Yuhan Gao, Tiejia Jiang, Yixuan Yuan, Xiaolong Ye, Siwei Ye, Chenggang Yan
{"title":"Dual Adaptive Grouped Multivariate Variational Mode Decomposition for Physiological Signals.","authors":"Tian Zhang, Duanpo Wu, Lian Zhang, Yuhan Gao, Tiejia Jiang, Yixuan Yuan, Xiaolong Ye, Siwei Ye, Chenggang Yan","doi":"10.1109/TBME.2026.3741411","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Grouped multivariate variational mode decomposition (GMVMD) is sensitive to the preset group number $G$ and common mode number $K$. To improve its adaptability to multichannel electroencephalogram (EEG) and electrocardiogram (ECG) signals, we determine both automatically.</p><p><strong>Methods: </strong>We propose dual adaptive grouped multivariate variational mode decomposition (DA-GMVMD) with three stages: adaptive grouping, adaptive $K$ search and grouped decomposition. Adaptive grouping constructs a channel graph and determines the channel groups using the Laplacian eigengap and spectral clustering. Adaptive $K$ search uses probe-mode energy shares to select a mode number for each group. Grouped decomposition applies multivariate variational mode decomposition (MVMD) to each group and combines the results.</p><p><strong>Results: </strong>On synthetic signals, DA-GMVMD recovers the underlying grouping structure and remains stable across noise levels. In a separate synthetic test, it recovers the group-specific mode numbers. On the CHB-MIT, MODMA, and PTB-XL datasets, it achieves lower reconstruction error than GMVMD with fixed parameters and several baselines related to MVMD. The reduction relative to GMVMD is significant on CHB-MIT and MODMA. On PTB-XL, DA-GMVMD has a lower observed mean reconstruction error. The reconstructed signals retain seizure classification information on CHB-MIT, regional band power and bilateral asymmetry on MODMA, and R-peak timing and ECG intervals on PTB-XL.</p><p><strong>Conclusion: </strong>DA-GMVMD adapts the channel groups and their mode numbers to the signal content while retaining the evaluated EEG and ECG information in the reconstructed signals.</p><p><strong>Significance: </strong>DA-GMVMD makes multichannel EEG and ECG decomposition less sensitive to a manually preset group number and common mode number.</p>","PeriodicalId":13245,"journal":{"name":"IEEE Transactions on Biomedical Engineering","volume":"PP ","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2026-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/TBME.2026.3741411","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Grouped multivariate variational mode decomposition (GMVMD) is sensitive to the preset group number $G$ and common mode number $K$. To improve its adaptability to multichannel electroencephalogram (EEG) and electrocardiogram (ECG) signals, we determine both automatically.

Methods: We propose dual adaptive grouped multivariate variational mode decomposition (DA-GMVMD) with three stages: adaptive grouping, adaptive $K$ search and grouped decomposition. Adaptive grouping constructs a channel graph and determines the channel groups using the Laplacian eigengap and spectral clustering. Adaptive $K$ search uses probe-mode energy shares to select a mode number for each group. Grouped decomposition applies multivariate variational mode decomposition (MVMD) to each group and combines the results.

Results: On synthetic signals, DA-GMVMD recovers the underlying grouping structure and remains stable across noise levels. In a separate synthetic test, it recovers the group-specific mode numbers. On the CHB-MIT, MODMA, and PTB-XL datasets, it achieves lower reconstruction error than GMVMD with fixed parameters and several baselines related to MVMD. The reduction relative to GMVMD is significant on CHB-MIT and MODMA. On PTB-XL, DA-GMVMD has a lower observed mean reconstruction error. The reconstructed signals retain seizure classification information on CHB-MIT, regional band power and bilateral asymmetry on MODMA, and R-peak timing and ECG intervals on PTB-XL.

Conclusion: DA-GMVMD adapts the channel groups and their mode numbers to the signal content while retaining the evaluated EEG and ECG information in the reconstructed signals.

Significance: DA-GMVMD makes multichannel EEG and ECG decomposition less sensitive to a manually preset group number and common mode number.

生理信号的双自适应分组多变量变分模态分解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Biomedical Engineering
IEEE Transactions on Biomedical Engineering 工程技术-工程:生物医学
CiteScore
9.40
自引率
4.30%
发文量
880
审稿时长
2.5 months
期刊介绍: IEEE Transactions on Biomedical Engineering contains basic and applied papers dealing with biomedical engineering. Papers range from engineering development in methods and techniques with biomedical applications to experimental and clinical investigations with engineering contributions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书