[Heatwaves and Resilience of Hospital Geriatric Care Pathways: Results of the Repeated National PUGG FLASH-HEATWAVE 2026 survey].

IF 0.3
Cédric Annweiler, Jacques Boddaert, Jean-Pierre Aquino, Gaëtan Gavazzi, Sylvie Bonin-Guillaume
{"title":"[Heatwaves and Resilience of Hospital Geriatric Care Pathways: Results of the Repeated National PUGG FLASH-HEATWAVE 2026 survey].","authors":"Cédric Annweiler, Jacques Boddaert, Jean-Pierre Aquino, Gaëtan Gavazzi, Sylvie Bonin-Guillaume","doi":"10.1684/pnv.2026.1301","DOIUrl":null,"url":null,"abstract":"<p><p>Extreme heat disproportionately affects frail older adults and may simultaneously disrupt hospital capacity, working conditions, and geriatric care pathways. We aimed to describe thermal conditions, capacity strain, and organizational adaptations in acute geriatric units (AGUs) during a heatwave and one week later, and to describe conditions in medical rehabilitation units (MRUs). PUGG FLASH-HEATWAVE was a repeated national observational, non-interventional service-level survey. Phase 1 surveyed AGUs on 25-26 June 2026; phase 2 surveyed AGUs and MRUs on 2-3 July 2026. Data were aggregated at the service level. Because no stable unit identifier was available, AGU data from the two survey waves were compared as independent samples using chi-square or Fisher's exact tests. Exploratory Mann-Whitney tests assessed the association between room cooling and reported events in phase 1. One hundred and twelve AGUs, representing 4,268 usual beds, participated in phase 1; phase 2 included 30 AGUs (1,007 beds) and 26 MRUs (1,490 beds). In phase 1, 45.5% of AGUs considered patient-room temperatures to be intolerable, 71.4% reported excessive room temperatures as an operational difficulty, and 88.4% reported staff fatigue. Major or critical emergency-department strain affected 57.1% of units, while 64.3% reported capacity strain with consequences for admissions. Downstream rehabilitation and other care capacity was considered insufficient by 87.5% of AGUs. One week later, the proportion of AGUs reporting at least partly tolerable room temperatures had increased from 53.6% to 100.0% (p < 0.001), while at least moderate emergency-department strain decreased from 91.1% to 63.3% (p < 0.001), capacity strain with operational consequences from 64.3% to 40.0% (p = 0.016), and staff fatigue from 88.4% to 50.0% (p < 0.001). Downstream capacity insufficiency remained unchanged (87.5% versus 86.7%; p = 0.903). Among MRUs, 65.4% reported patient rooms that were intolerable or only partly tolerable, 73.1% had postponed or refused admissions, and 88.5% had adapted rehabilitation activities. In phase 1, units with at least partly cooled rooms reported fewer heat-related complications and heatstroke events in unadjusted exploratory analyses. The heatwave acted as a stress test for an already fragile system. Improvements in several indicators of acute strain did not resolve the persistent downstream bottleneck. A national multi-year policy should integrate thermal adaptation of healthcare facilities, protected seasonal capacity, adequate workforce resources, and regional coordination across geriatric care pathways.</p>","PeriodicalId":520632,"journal":{"name":"Geriatrie et psychologie neuropsychiatrie du vieillissement","volume":"24 3","pages":"249-260"},"PeriodicalIF":0.3000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geriatrie et psychologie neuropsychiatrie du vieillissement","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1684/pnv.2026.1301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Extreme heat disproportionately affects frail older adults and may simultaneously disrupt hospital capacity, working conditions, and geriatric care pathways. We aimed to describe thermal conditions, capacity strain, and organizational adaptations in acute geriatric units (AGUs) during a heatwave and one week later, and to describe conditions in medical rehabilitation units (MRUs). PUGG FLASH-HEATWAVE was a repeated national observational, non-interventional service-level survey. Phase 1 surveyed AGUs on 25-26 June 2026; phase 2 surveyed AGUs and MRUs on 2-3 July 2026. Data were aggregated at the service level. Because no stable unit identifier was available, AGU data from the two survey waves were compared as independent samples using chi-square or Fisher's exact tests. Exploratory Mann-Whitney tests assessed the association between room cooling and reported events in phase 1. One hundred and twelve AGUs, representing 4,268 usual beds, participated in phase 1; phase 2 included 30 AGUs (1,007 beds) and 26 MRUs (1,490 beds). In phase 1, 45.5% of AGUs considered patient-room temperatures to be intolerable, 71.4% reported excessive room temperatures as an operational difficulty, and 88.4% reported staff fatigue. Major or critical emergency-department strain affected 57.1% of units, while 64.3% reported capacity strain with consequences for admissions. Downstream rehabilitation and other care capacity was considered insufficient by 87.5% of AGUs. One week later, the proportion of AGUs reporting at least partly tolerable room temperatures had increased from 53.6% to 100.0% (p < 0.001), while at least moderate emergency-department strain decreased from 91.1% to 63.3% (p < 0.001), capacity strain with operational consequences from 64.3% to 40.0% (p = 0.016), and staff fatigue from 88.4% to 50.0% (p < 0.001). Downstream capacity insufficiency remained unchanged (87.5% versus 86.7%; p = 0.903). Among MRUs, 65.4% reported patient rooms that were intolerable or only partly tolerable, 73.1% had postponed or refused admissions, and 88.5% had adapted rehabilitation activities. In phase 1, units with at least partly cooled rooms reported fewer heat-related complications and heatstroke events in unadjusted exploratory analyses. The heatwave acted as a stress test for an already fragile system. Improvements in several indicators of acute strain did not resolve the persistent downstream bottleneck. A national multi-year policy should integrate thermal adaptation of healthcare facilities, protected seasonal capacity, adequate workforce resources, and regional coordination across geriatric care pathways.

[热浪和医院老年护理路径的弹性:全国PUGG FLASH-HEATWAVE 2026重复调查的结果]。
极端高温对体弱多病的老年人的影响尤为严重,并可能同时扰乱医院能力、工作条件和老年护理途径。我们的目的是描述热浪期间和一周后急性老年病房(agu)的热条件、能力紧张和组织适应,并描述医疗康复病房(mru)的条件。PUGG FLASH-HEATWAVE是一项全国性的非干预性服务水平调查。第一阶段于2026年6月25日至26日对agu进行了调查;第二阶段于2026年7月2日至3日调查了agu和mru。数据在服务级别聚合。由于没有稳定的单位标识符,两波调查的AGU数据作为独立样本使用卡方检验或Fisher精确检验进行比较。探索性曼-惠特尼测试评估了房间冷却与第一阶段报告事件之间的关系。112个agu,代表4268个常规床位,参与了第一阶段;第二阶段包括30个agu(1007个床位)和26个mru(1490个床位)。在第一阶段,45.5%的agu认为病房温度难以忍受,71.4%的agu认为室温过高是操作困难,88.4%的agu认为工作人员疲劳。57.1%的单位受到重大或危急急诊科压力的影响,而64.3%的单位报告能力紧张导致入院。87.5%的agu认为下游康复和其他护理能力不足。一周后,报告至少部分耐受室温的agu比例从53.6%增加到100.0% (p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书