Michaela Rippl, Sarikia Moewes, Daniel Arian Kraus, Michael Drey, Ralf Schmidmaier, Peyman Hadji
{"title":"Age-related bone mineral density patterns in a large German clinical DXA cohort: device-specific comparisons with international reference populations.","authors":"Michaela Rippl, Sarikia Moewes, Daniel Arian Kraus, Michael Drey, Ralf Schmidmaier, Peyman Hadji","doi":"10.1007/s00198-026-08245-6","DOIUrl":null,"url":null,"abstract":"<p><p>In a large German clinical DXA cohort, comparisons with international reference populations were strongly device-dependent. iDXA values were consistently lower, whereas Prodigy Pro values showed closer but age- and cohort-dependent agreement. The data should not be interpreted as scanner-independent German normative reference values.</p><p><strong>Purpose: </strong>To describe age-related bone mineral density patterns in a German DXA cohort and to compare device-specific femoral neck (FN) and total hip (TH) standardized BMD values with international reference cohorts.</p><p><strong>Methods: </strong>We retrospectively analyzed data from 6,086 women using GE Lunar iDXA or Prodigy Pro systems. Device-related differences were evaluated separately by age-group and measurement site using absolute and percentage differences, Hedges' g, Welch tests, and multiple comparison adjustment. For external comparisons, FN and TH BMD data for women aged 20-79 years were converted to standardized BMD and compared separately by device with NHANES III, the Irish DXA-HIP study, and the Italian DINS study. Hedges' g with 95% confidence intervals, two-sided Welch tests, and Holm-adjusted p values were calculated from summary statistics.</p><p><strong>Results: </strong>Prodigy Pro BMD values were higher than iDXA across most age groups and measurement sites, with moderate effect sizes in younger and middle-aged women and smaller differences at older ages. In external comparisons, iDXA sBMD was lower than all reference cohorts in all 36 comparisons (age/site/reference), remaining significant after Holm adjustment. Prodigy Pro showed smaller and age-dependent differences, with 18 of 36 comparisons remaining Holm-significant. Across the reference cohorts, Prodigy Pro percentage differences ranged from -8.9% to 1.3%, whereas iDXA ranged from -19.0% to -1.8%.</p><p><strong>Conclusion: </strong>Comparisons with international reference cohorts were strongly dependent on the DXA device. The present clinical cohort should not be interpreted as a scanner-independent German normative reference population. Device-stratified results provide a more appropriate description of concordance with international datasets than pooled analyses.</p>","PeriodicalId":520737,"journal":{"name":"Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA","volume":" ","pages":""},"PeriodicalIF":5.4000,"publicationDate":"2026-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00198-026-08245-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In a large German clinical DXA cohort, comparisons with international reference populations were strongly device-dependent. iDXA values were consistently lower, whereas Prodigy Pro values showed closer but age- and cohort-dependent agreement. The data should not be interpreted as scanner-independent German normative reference values.
Purpose: To describe age-related bone mineral density patterns in a German DXA cohort and to compare device-specific femoral neck (FN) and total hip (TH) standardized BMD values with international reference cohorts.
Methods: We retrospectively analyzed data from 6,086 women using GE Lunar iDXA or Prodigy Pro systems. Device-related differences were evaluated separately by age-group and measurement site using absolute and percentage differences, Hedges' g, Welch tests, and multiple comparison adjustment. For external comparisons, FN and TH BMD data for women aged 20-79 years were converted to standardized BMD and compared separately by device with NHANES III, the Irish DXA-HIP study, and the Italian DINS study. Hedges' g with 95% confidence intervals, two-sided Welch tests, and Holm-adjusted p values were calculated from summary statistics.
Results: Prodigy Pro BMD values were higher than iDXA across most age groups and measurement sites, with moderate effect sizes in younger and middle-aged women and smaller differences at older ages. In external comparisons, iDXA sBMD was lower than all reference cohorts in all 36 comparisons (age/site/reference), remaining significant after Holm adjustment. Prodigy Pro showed smaller and age-dependent differences, with 18 of 36 comparisons remaining Holm-significant. Across the reference cohorts, Prodigy Pro percentage differences ranged from -8.9% to 1.3%, whereas iDXA ranged from -19.0% to -1.8%.
Conclusion: Comparisons with international reference cohorts were strongly dependent on the DXA device. The present clinical cohort should not be interpreted as a scanner-independent German normative reference population. Device-stratified results provide a more appropriate description of concordance with international datasets than pooled analyses.