Electrophoretic deposition of CaP-TiSiN composite coatings on 316L stainless steel: corrosion resistance and in vitro cytocompatibility.

Q3 Engineering
Ahmed S Abbas, Ahmed Hafedh Mohammed, Mohammed Dakhil Abbas, Zaid Kareem, Mohammed Ali Abdulrehman, Ali M Flayyih
{"title":"Electrophoretic deposition of CaP-TiSiN composite coatings on 316L stainless steel: corrosion resistance and in vitro cytocompatibility.","authors":"Ahmed S Abbas, Ahmed Hafedh Mohammed, Mohammed Dakhil Abbas, Zaid Kareem, Mohammed Ali Abdulrehman, Ali M Flayyih","doi":"10.1080/03091902.2026.2741144","DOIUrl":null,"url":null,"abstract":"<p><p>The EPD technique was used to synthesize CaP-TiSiN composite coatings on 316 L stainless steel to enhance its surface mechanical, electrochemical, and biological properties. The fabricated coatings were characterized by SEM, EDS, XRD, water contact-angle determination, Vickers microhardness test, scratch adhesion test, potentiodynamic polarization, and in vitro MTT test on MC3T3-E1 osteoblast-like cells. The CaP-TiSiN composite coating possessed a dense, relatively homogeneous microstructure with uniform distribution of the constituents. The microhardness value rose from 177.0 HV of bare 316 L to 602.4 HV of the CaP-TiSiN coating, and the scratch critical load was 18.8 N. Corrosion rate dropped from 0.00057 to 0.00007 mm/year, and the water contact angle became 54.3°, which indicates improvement in wettability. In MTT test, the CaP-TiSiN-coated samples showed maximum metabolic activity at all times, which was achieved as high as 116.3% on day 5 and significantly higher than TiSiN coating (<i>p</i> < 0.05) and HA coating on day 5 (<i>p</i> = 0.041). This suggests that EPD-synthesized CaP-TiSiN composite coatings could be employed as efficient surface modifications of 316 L stainless steel in biomedicine.</p>","PeriodicalId":39637,"journal":{"name":"Journal of Medical Engineering and Technology","volume":" ","pages":"1-17"},"PeriodicalIF":0.0000,"publicationDate":"2026-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/03091902.2026.2741144","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

The EPD technique was used to synthesize CaP-TiSiN composite coatings on 316 L stainless steel to enhance its surface mechanical, electrochemical, and biological properties. The fabricated coatings were characterized by SEM, EDS, XRD, water contact-angle determination, Vickers microhardness test, scratch adhesion test, potentiodynamic polarization, and in vitro MTT test on MC3T3-E1 osteoblast-like cells. The CaP-TiSiN composite coating possessed a dense, relatively homogeneous microstructure with uniform distribution of the constituents. The microhardness value rose from 177.0 HV of bare 316 L to 602.4 HV of the CaP-TiSiN coating, and the scratch critical load was 18.8 N. Corrosion rate dropped from 0.00057 to 0.00007 mm/year, and the water contact angle became 54.3°, which indicates improvement in wettability. In MTT test, the CaP-TiSiN-coated samples showed maximum metabolic activity at all times, which was achieved as high as 116.3% on day 5 and significantly higher than TiSiN coating (p < 0.05) and HA coating on day 5 (p = 0.041). This suggests that EPD-synthesized CaP-TiSiN composite coatings could be employed as efficient surface modifications of 316 L stainless steel in biomedicine.

316L不锈钢表面CaP-TiSiN复合涂层的电泳沉积:耐蚀性和体外细胞相容性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Medical Engineering and Technology
Journal of Medical Engineering and Technology Engineering-Biomedical Engineering
CiteScore
4.60
自引率
0.00%
发文量
77
期刊介绍: The Journal of Medical Engineering & Technology is an international, independent, multidisciplinary, bimonthly journal promoting an understanding of the physiological processes underlying disease processes and the appropriate application of technology. Features include authoritative review papers, the reporting of original research, and evaluation reports on new and existing techniques and devices. Each issue of the journal contains a comprehensive information service which provides news relevant to the world of medical technology, details of new products, book reviews, and selected contents of related journals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书