Performance validation of a new finger-root-adapted ring-shaped oximeter sensor during stepwise steady-state inspired hypoxia.

IF 2.6 3区 医学 Q2 ANESTHESIOLOGY
Yihan Zhang, Lan Gao, Wenxiu Zhu, Weiqiang Chen, Yue Liu, Huixin Chen, Yanling Wang, Yalan Li, Fei Huang, Jieke Tang, Shangrong Li
{"title":"Performance validation of a new finger-root-adapted ring-shaped oximeter sensor during stepwise steady-state inspired hypoxia.","authors":"Yihan Zhang, Lan Gao, Wenxiu Zhu, Weiqiang Chen, Yue Liu, Huixin Chen, Yanling Wang, Yalan Li, Fei Huang, Jieke Tang, Shangrong Li","doi":"10.1007/s10877-026-01500-5","DOIUrl":null,"url":null,"abstract":"<p><p>Peripheral pulse oxygen saturation (SpO<sub>2</sub>) is a widely applied substitute parameter to arterial oxygen saturation (SaO<sub>2</sub>). Optimized morphological design and geometrical arrangement of the light-source and photodetector without compromising their precision, can maximize the clinical utility of the SpO<sub>2</sub> sensors. We analyzed data of 36 participants collected from two multicenter trials that examined the performances of 3 transmittance oximeter sensors. A finger-root-adapted ring-shaped sensor with light-source and detector located on the sides of the finger, was compared with 2 fingertip-adapted designs (finger-clip and finger-case), whose light-sources and detectors were located on the antero-posterior axis of the finger. A stepwise steady-state inspired hypoxia protocol according to ISO 80,601 2-61: 2017 were adopted to examine the SpO<sub>2</sub> measurements of all the sensors obtained at 5 different SaO<sub>2</sub> levels (100%-97%, 92% - 96%, 85% ~ 91%, 78% ~ 84%, 70% ~ 77) under either quiescent or motion condition as well as in darkly or lightly pigmented populations. Under each tested condition, all the sensors presented an accuracy root mean square (Arms) within 2%. Bland-Altman analysis of all the sensors demonstrated narrow limits of agreement. Paired SaO₂ and SpO₂ values were fitted to linear regression lines and yielded high coefficients of determination (R² > 0.97) for all sensors, indicating excellent distribution matches. The finger-ring sensor was rated by the participants to offer higher finger-movement flexibility, attachment stability and more comfortable experiences to users. The finger-root-adapted ring-shaped oximetry sensor demonstrated high precision and is more user-friendly for SpO<sub>2</sub> monitoring.</p>","PeriodicalId":15513,"journal":{"name":"Journal of Clinical Monitoring and Computing","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2026-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Monitoring and Computing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10877-026-01500-5","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Peripheral pulse oxygen saturation (SpO2) is a widely applied substitute parameter to arterial oxygen saturation (SaO2). Optimized morphological design and geometrical arrangement of the light-source and photodetector without compromising their precision, can maximize the clinical utility of the SpO2 sensors. We analyzed data of 36 participants collected from two multicenter trials that examined the performances of 3 transmittance oximeter sensors. A finger-root-adapted ring-shaped sensor with light-source and detector located on the sides of the finger, was compared with 2 fingertip-adapted designs (finger-clip and finger-case), whose light-sources and detectors were located on the antero-posterior axis of the finger. A stepwise steady-state inspired hypoxia protocol according to ISO 80,601 2-61: 2017 were adopted to examine the SpO2 measurements of all the sensors obtained at 5 different SaO2 levels (100%-97%, 92% - 96%, 85% ~ 91%, 78% ~ 84%, 70% ~ 77) under either quiescent or motion condition as well as in darkly or lightly pigmented populations. Under each tested condition, all the sensors presented an accuracy root mean square (Arms) within 2%. Bland-Altman analysis of all the sensors demonstrated narrow limits of agreement. Paired SaO₂ and SpO₂ values were fitted to linear regression lines and yielded high coefficients of determination (R² > 0.97) for all sensors, indicating excellent distribution matches. The finger-ring sensor was rated by the participants to offer higher finger-movement flexibility, attachment stability and more comfortable experiences to users. The finger-root-adapted ring-shaped oximetry sensor demonstrated high precision and is more user-friendly for SpO2 monitoring.

一种新型指根适应环形血氧计传感器在逐步稳态启发缺氧中的性能验证。
外周脉搏血氧饱和度(SpO2)是广泛应用于动脉血氧饱和度(SaO2)的替代参数。优化光源和光电探测器的形态设计和几何布置,在不影响其精度的前提下,最大限度地提高SpO2传感器的临床应用价值。我们分析了来自两个多中心试验的36名参与者的数据,这些试验检查了3种透光血氧计传感器的性能。将光源和检测器位于手指侧面的指根适应型环形传感器与光源和检测器位于手指前后轴线的两种指尖适应型设计(指夹和指盒)进行比较。采用ISO 80,601 2-61: 2017的逐步稳态启发缺氧方案,检查在静止或运动状态以及深肤色或浅肤色人群中,在5种不同的SaO2水平(100%-97%,92% - 96%,85% ~ 91%,78% ~ 84%,70% ~ 77%)下获得的所有传感器的SpO2测量值。在每个测试条件下,所有传感器的精度均方根(Arms)都在2%以内。布兰德-奥特曼对所有传感器的分析表明,一致性的范围很窄。成对的SaO₂和SpO₂值拟合到线性回归线上,所有传感器的决定系数都很高(R²> 0.97),表明分布匹配良好。手指环传感器被参与者评价为提供更高的手指运动灵活性,附着稳定性和更舒适的用户体验。手指根部适应的环形血氧传感器精度高,对SpO2监测更加友好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.30
自引率
13.60%
发文量
144
审稿时长
6-12 weeks
期刊介绍: The Journal of Clinical Monitoring and Computing is a clinical journal publishing papers related to technology in the fields of anaesthesia, intensive care medicine, emergency medicine, and peri-operative medicine. The journal has links with numerous specialist societies, including editorial board representatives from the European Society for Computing and Technology in Anaesthesia and Intensive Care (ESCTAIC), the Society for Technology in Anesthesia (STA), the Society for Complex Acute Illness (SCAI) and the NAVAt (NAVigating towards your Anaestheisa Targets) group. The journal publishes original papers, narrative and systematic reviews, technological notes, letters to the editor, editorial or commentary papers, and policy statements or guidelines from national or international societies. The journal encourages debate on published papers and technology, including letters commenting on previous publications or technological concerns. The journal occasionally publishes special issues with technological or clinical themes, or reports and abstracts from scientificmeetings. Special issues proposals should be sent to the Editor-in-Chief. Specific details of types of papers, and the clinical and technological content of papers considered within scope can be found in instructions for authors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书