Yihan Zhang, Lan Gao, Wenxiu Zhu, Weiqiang Chen, Yue Liu, Huixin Chen, Yanling Wang, Yalan Li, Fei Huang, Jieke Tang, Shangrong Li
{"title":"Performance validation of a new finger-root-adapted ring-shaped oximeter sensor during stepwise steady-state inspired hypoxia.","authors":"Yihan Zhang, Lan Gao, Wenxiu Zhu, Weiqiang Chen, Yue Liu, Huixin Chen, Yanling Wang, Yalan Li, Fei Huang, Jieke Tang, Shangrong Li","doi":"10.1007/s10877-026-01500-5","DOIUrl":null,"url":null,"abstract":"<p><p>Peripheral pulse oxygen saturation (SpO<sub>2</sub>) is a widely applied substitute parameter to arterial oxygen saturation (SaO<sub>2</sub>). Optimized morphological design and geometrical arrangement of the light-source and photodetector without compromising their precision, can maximize the clinical utility of the SpO<sub>2</sub> sensors. We analyzed data of 36 participants collected from two multicenter trials that examined the performances of 3 transmittance oximeter sensors. A finger-root-adapted ring-shaped sensor with light-source and detector located on the sides of the finger, was compared with 2 fingertip-adapted designs (finger-clip and finger-case), whose light-sources and detectors were located on the antero-posterior axis of the finger. A stepwise steady-state inspired hypoxia protocol according to ISO 80,601 2-61: 2017 were adopted to examine the SpO<sub>2</sub> measurements of all the sensors obtained at 5 different SaO<sub>2</sub> levels (100%-97%, 92% - 96%, 85% ~ 91%, 78% ~ 84%, 70% ~ 77) under either quiescent or motion condition as well as in darkly or lightly pigmented populations. Under each tested condition, all the sensors presented an accuracy root mean square (Arms) within 2%. Bland-Altman analysis of all the sensors demonstrated narrow limits of agreement. Paired SaO₂ and SpO₂ values were fitted to linear regression lines and yielded high coefficients of determination (R² > 0.97) for all sensors, indicating excellent distribution matches. The finger-ring sensor was rated by the participants to offer higher finger-movement flexibility, attachment stability and more comfortable experiences to users. The finger-root-adapted ring-shaped oximetry sensor demonstrated high precision and is more user-friendly for SpO<sub>2</sub> monitoring.</p>","PeriodicalId":15513,"journal":{"name":"Journal of Clinical Monitoring and Computing","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2026-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Monitoring and Computing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10877-026-01500-5","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Peripheral pulse oxygen saturation (SpO2) is a widely applied substitute parameter to arterial oxygen saturation (SaO2). Optimized morphological design and geometrical arrangement of the light-source and photodetector without compromising their precision, can maximize the clinical utility of the SpO2 sensors. We analyzed data of 36 participants collected from two multicenter trials that examined the performances of 3 transmittance oximeter sensors. A finger-root-adapted ring-shaped sensor with light-source and detector located on the sides of the finger, was compared with 2 fingertip-adapted designs (finger-clip and finger-case), whose light-sources and detectors were located on the antero-posterior axis of the finger. A stepwise steady-state inspired hypoxia protocol according to ISO 80,601 2-61: 2017 were adopted to examine the SpO2 measurements of all the sensors obtained at 5 different SaO2 levels (100%-97%, 92% - 96%, 85% ~ 91%, 78% ~ 84%, 70% ~ 77) under either quiescent or motion condition as well as in darkly or lightly pigmented populations. Under each tested condition, all the sensors presented an accuracy root mean square (Arms) within 2%. Bland-Altman analysis of all the sensors demonstrated narrow limits of agreement. Paired SaO₂ and SpO₂ values were fitted to linear regression lines and yielded high coefficients of determination (R² > 0.97) for all sensors, indicating excellent distribution matches. The finger-ring sensor was rated by the participants to offer higher finger-movement flexibility, attachment stability and more comfortable experiences to users. The finger-root-adapted ring-shaped oximetry sensor demonstrated high precision and is more user-friendly for SpO2 monitoring.
期刊介绍:
The Journal of Clinical Monitoring and Computing is a clinical journal publishing papers related to technology in the fields of anaesthesia, intensive care medicine, emergency medicine, and peri-operative medicine.
The journal has links with numerous specialist societies, including editorial board representatives from the European Society for Computing and Technology in Anaesthesia and Intensive Care (ESCTAIC), the Society for Technology in Anesthesia (STA), the Society for Complex Acute Illness (SCAI) and the NAVAt (NAVigating towards your Anaestheisa Targets) group.
The journal publishes original papers, narrative and systematic reviews, technological notes, letters to the editor, editorial or commentary papers, and policy statements or guidelines from national or international societies. The journal encourages debate on published papers and technology, including letters commenting on previous publications or technological concerns. The journal occasionally publishes special issues with technological or clinical themes, or reports and abstracts from scientificmeetings. Special issues proposals should be sent to the Editor-in-Chief. Specific details of types of papers, and the clinical and technological content of papers considered within scope can be found in instructions for authors.