{"title":"Refractive outcomes of posterior chamber phakic intraocular lens implantation with a central port design.","authors":"Guillermo R Vera-Duarte, Naomi C Zatarain-Barrón, David Jimenez-Collado, Carlos A Müller-Morales, Arturo Ramirez-Miranda, Enrique O Graue-Hernández, Arturo Gómez-Bastar, Alejandro Navas","doi":"10.24875/CIRU.24000591","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The objective of the study is to evaluate the visual and refractive outcomes of implantable Collamer lens (ICL) implantation with a new central port design.</p><p><strong>Methods: </strong>This is a retrospective observational study of patients with myopia and myopic astigmatism who underwent procedures for the ICL (STAAR Surgical) between 2013 and 2022. Measurements were taken for uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest and cycloplegic refraction, and intraocular pressure.</p><p><strong>Results: </strong>254 eyes of 135 patients who underwent. Of the 254 ICLs implanted, 226 (88.97%) were toric. Mean follow-up was 15.05 ± 15.12 months. Mean pre-operative sphere was -9.65 ± 4.46 D (-0.00--25.00 D) and the post-operative sphere was 0.07 ± 1.12 D (-5.75-2.50 D). Pre-operative mean spherical equivalent was -11.24 ± 4.35 D (-25-6.25 D) and -0.38 ± 1.16 D (-6.75-2.12 D) postoperatively. Mean pre-operative UDVA was 1.58 ± 0.44 (0.4-2.5) and the mean post-operative UDVA was 0.17 ± 0.17 (0-1.18). Mean pre-operative CDVA was 0.15 ± 0.12 (0-0.6) and the post-operative CDVA was 0.08 ± 0.09 (0-0.54 D).</p><p><strong>Conclusions: </strong>This study showcases a noteworthy level of visual and refractive efficacy in individuals who underwent implantation of ICL V4c models. The surgical procedure proved highly effective and safe for correcting myopia and astigmatism.</p>","PeriodicalId":93936,"journal":{"name":"Cirugia y cirujanos","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cirugia y cirujanos","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24875/CIRU.24000591","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The objective of the study is to evaluate the visual and refractive outcomes of implantable Collamer lens (ICL) implantation with a new central port design.

Methods: This is a retrospective observational study of patients with myopia and myopic astigmatism who underwent procedures for the ICL (STAAR Surgical) between 2013 and 2022. Measurements were taken for uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest and cycloplegic refraction, and intraocular pressure.

Results: 254 eyes of 135 patients who underwent. Of the 254 ICLs implanted, 226 (88.97%) were toric. Mean follow-up was 15.05 ± 15.12 months. Mean pre-operative sphere was -9.65 ± 4.46 D (-0.00--25.00 D) and the post-operative sphere was 0.07 ± 1.12 D (-5.75-2.50 D). Pre-operative mean spherical equivalent was -11.24 ± 4.35 D (-25-6.25 D) and -0.38 ± 1.16 D (-6.75-2.12 D) postoperatively. Mean pre-operative UDVA was 1.58 ± 0.44 (0.4-2.5) and the mean post-operative UDVA was 0.17 ± 0.17 (0-1.18). Mean pre-operative CDVA was 0.15 ± 0.12 (0-0.6) and the post-operative CDVA was 0.08 ± 0.09 (0-0.54 D).

Conclusions: This study showcases a noteworthy level of visual and refractive efficacy in individuals who underwent implantation of ICL V4c models. The surgical procedure proved highly effective and safe for correcting myopia and astigmatism.

中心孔型后房型人工晶状体植入术的屈光效果。
目的:评价一种新型中心孔设计的可植入式屈光体(ICL)植入术的视力和屈光效果。方法:这是一项回顾性观察研究,对2013年至2022年间接受ICL (STAAR Surgical)手术的近视和近视散光患者进行研究。测量未矫正距离视力(UDVA)、矫正距离视力(CDVA)、明显屈光和睫状体麻痹性屈光以及眼压。结果:135例患者254只眼接受了手术。254例植入的ICLs中,有226例(88.97%)成功。平均随访15.05±15.12个月。术前球平均为-9.65±4.46 D (-0.00 ~ 25.00 D),术后球平均为0.07±1.12 D (-5.75 ~ 2.50 D)。术前平均球等效为-11.24±4.35 D (-25-6.25 D),术后平均球等效为-0.38±1.16 D (-6.75-2.12 D)。术前平均UDVA为1.58±0.44(0.4 ~ 2.5),术后平均UDVA为0.17±0.17(0 ~ 1.18)。术前平均CDVA为0.15±0.12(0-0.6),术后平均CDVA为0.08±0.09 (0-0.54 D)。结论:本研究显示,接受ICL V4c模型植入术的个体视力和屈光效果显著。事实证明,该手术对矫正近视和散光非常有效和安全。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书