Delayed fluorescence on indocyanine green angiography reflects impaired red blood cell perfusion: implications for intraoperative perfusion assessment in colorectal surgery.

IF 2.2 3区 医学 Q2 SURGERY
Tetsuro Maruyama, Shunsuke Kainuma, Toru Tochigi, Masaya Uesato, Gaku Ohira, Satoshi Endo, Shunsuke Imanishi, Hiroyuki Amagai, Atsushi Hirata, Hisahiro Matsubara
{"title":"Delayed fluorescence on indocyanine green angiography reflects impaired red blood cell perfusion: implications for intraoperative perfusion assessment in colorectal surgery.","authors":"Tetsuro Maruyama, Shunsuke Kainuma, Toru Tochigi, Masaya Uesato, Gaku Ohira, Satoshi Endo, Shunsuke Imanishi, Hiroyuki Amagai, Atsushi Hirata, Hisahiro Matsubara","doi":"10.1007/s13304-026-02856-8","DOIUrl":null,"url":null,"abstract":"<p><p>Indocyanine green fluorescence angiography (ICG-FA) is widely used for intraoperative perfusion assessment in colorectal surgery. Although delayed fluorescence is commonly interpreted as impaired perfusion, its underlying hemodynamic characteristics remain unclear. A porcine model of mesenteric division was used to evaluate intestinal perfusion using both ICG-FA and Blue Laser Imaging-microcirculation (BLI-M), which enables direct visualization of red blood cell (RBC) flow. Perfusion boundaries, fluorescence dynamics, and microcirculatory flow were analyzed on both mucosal and serosal surfaces. A mucosal bridge model was created to assess the role of submucosal perfusion. In regions showing delayed fluorescence on ICG-FA, no detectable RBC flow was observed on either the mucosal or serosal surfaces using BLI-M. Despite this, fluorescence gradually increased and reached levels comparable to well-perfused regions. Quantitative analysis demonstrated prolonged time to fluorescence onset and reduced slope in delayed regions, while maximum fluorescence intensity was similar across regions. These findings suggest that delayed fluorescence reflects temporal delay rather than adequate perfusion, likely due to plasma-dominant flow or extremely low-velocity microcirculation. The perfusion boundary identified by ICG-FA corresponded to mucosal perfusion rather than serosal perfusion, indicating a layer-specific discrepancy in intestinal blood flow. Delayed fluorescence on ICG-FA may represent regions with insufficient effective RBC perfusion despite preserved fluorescence intensity. Accurate identification of the initial perfusion boundary is essential, as reliance on delayed fluorescence may lead to inappropriate transection line selection and increased risk of anastomotic leakage. To our knowledge, this is the first study to provide direct experimental evidence elucidating the mechanism underlying delayed fluorescence observed in ICG-FA.</p>","PeriodicalId":23391,"journal":{"name":"Updates in Surgery","volume":" ","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2026-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Updates in Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s13304-026-02856-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Indocyanine green fluorescence angiography (ICG-FA) is widely used for intraoperative perfusion assessment in colorectal surgery. Although delayed fluorescence is commonly interpreted as impaired perfusion, its underlying hemodynamic characteristics remain unclear. A porcine model of mesenteric division was used to evaluate intestinal perfusion using both ICG-FA and Blue Laser Imaging-microcirculation (BLI-M), which enables direct visualization of red blood cell (RBC) flow. Perfusion boundaries, fluorescence dynamics, and microcirculatory flow were analyzed on both mucosal and serosal surfaces. A mucosal bridge model was created to assess the role of submucosal perfusion. In regions showing delayed fluorescence on ICG-FA, no detectable RBC flow was observed on either the mucosal or serosal surfaces using BLI-M. Despite this, fluorescence gradually increased and reached levels comparable to well-perfused regions. Quantitative analysis demonstrated prolonged time to fluorescence onset and reduced slope in delayed regions, while maximum fluorescence intensity was similar across regions. These findings suggest that delayed fluorescence reflects temporal delay rather than adequate perfusion, likely due to plasma-dominant flow or extremely low-velocity microcirculation. The perfusion boundary identified by ICG-FA corresponded to mucosal perfusion rather than serosal perfusion, indicating a layer-specific discrepancy in intestinal blood flow. Delayed fluorescence on ICG-FA may represent regions with insufficient effective RBC perfusion despite preserved fluorescence intensity. Accurate identification of the initial perfusion boundary is essential, as reliance on delayed fluorescence may lead to inappropriate transection line selection and increased risk of anastomotic leakage. To our knowledge, this is the first study to provide direct experimental evidence elucidating the mechanism underlying delayed fluorescence observed in ICG-FA.

吲哚菁绿血管造影延迟荧光反映红细胞灌注受损:对结直肠手术术中灌注评估的意义。
吲哚菁绿荧光血管造影(ICG-FA)广泛应用于结直肠手术术中血流灌注评估。虽然延迟荧光通常被解释为灌注受损,但其潜在的血流动力学特征尚不清楚。采用猪肠系膜分裂模型,采用ICG-FA和蓝光成像-微循环(BLI-M)来评估肠道灌注,BLI-M可以直接显示红细胞(RBC)流动。在粘膜和浆膜表面分析灌注边界、荧光动力学和微循环流动。建立粘膜桥模型,评价粘膜下灌注的作用。在ICG-FA显示延迟荧光的区域,BLI-M在粘膜或浆膜表面均未观察到可检测到的红细胞流动。尽管如此,荧光逐渐增加并达到与灌注良好的区域相当的水平。定量分析表明,延迟区荧光开始时间延长,斜率降低,而各区域的最大荧光强度相似。这些发现表明,延迟的荧光反映的是时间延迟,而不是充分的灌注,可能是由于等离子体为主的血流或极低速度的微循环。ICG-FA鉴定的灌注边界对应于粘膜灌注而非浆膜灌注,表明肠血流量存在层间差异。尽管保留了荧光强度,但ICG-FA上的延迟荧光可能代表有效红细胞灌注不足的区域。准确识别初始灌注边界至关重要,因为依赖延迟荧光可能导致不适当的横断线选择和增加吻合口漏的风险。据我们所知,这是第一个提供直接实验证据来阐明ICG-FA中观察到的延迟荧光机制的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Updates in Surgery
Updates in Surgery Medicine-Surgery
CiteScore
4.50
自引率
7.70%
发文量
208
期刊介绍: Updates in Surgery (UPIS) has been founded in 2010 as the official journal of the Italian Society of Surgery. It’s an international, English-language, peer-reviewed journal dedicated to the surgical sciences. Its main goal is to offer a valuable update on the most recent developments of those surgical techniques that are rapidly evolving, forcing the community of surgeons to a rigorous debate and a continuous refinement of standards of care. In this respect position papers on the mostly debated surgical approaches and accreditation criteria have been published and are welcome for the future. Beside its focus on general surgery, the journal draws particular attention to cutting edge topics and emerging surgical fields that are publishing in monothematic issues guest edited by well-known experts. Updates in Surgery has been considering various types of papers: editorials, comprehensive reviews, original studies and technical notes related to specific surgical procedures and techniques on liver, colorectal, gastric, pancreatic, robotic and bariatric surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书