Diagnostic accuracy of 18F-PSMA-1007 PET/CT and bone scintigraphy for detecting bone metastases in prostate cancer.

IF 2.1 4区 医学
Kazuhiro Kitajima, Sadahiro Naka, Koji Hatano, Motohide Uemura, Hidetaka Sasaki, Takashi Kamiya, Kenta Kurimoto, Daisuke Katayama, Hiroki Kato, Yuwei Liu, Jens Cardinale, Frederik L Giesel, Norio Nonomura, Tadashi Watabe
{"title":"Diagnostic accuracy of <sup>18</sup>F-PSMA-1007 PET/CT and bone scintigraphy for detecting bone metastases in prostate cancer.","authors":"Kazuhiro Kitajima, Sadahiro Naka, Koji Hatano, Motohide Uemura, Hidetaka Sasaki, Takashi Kamiya, Kenta Kurimoto, Daisuke Katayama, Hiroki Kato, Yuwei Liu, Jens Cardinale, Frederik L Giesel, Norio Nonomura, Tadashi Watabe","doi":"10.1007/s11604-026-02081-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The performance of <sup>18</sup>F-labeled prostate-specific membrane antigen (<sup>18</sup>F-PSMA-1007) positron emission tomography/computed tomography (PET/CT) and bone scintigraphy (BS) for detecting bone metastases in prostate cancer patients was compared.</p><p><strong>Materials and methods: </strong>One hundred prostate cancer patients (initial staging, n = 9; biochemical recurrence, n = 63; metastatic castration-resistant prostate cancer (mCRPC), n = 15; m0CRPC, n = 13) underwent <sup>18</sup>F-PSMA-1007 PET/CT and BS. The patient-, region-, and lesion-based performances of <sup>18</sup>F-PSMA-1007 PET/CT and BS for detecting bone metastases were evaluated by experienced readers using a five-point scale.</p><p><strong>Results: </strong>Bone metastases were identified in 46 (46.0%) patients, 99 (24.8%) of the 400 regions, and 528 lesions. In the analysis, the area under the receiver-operating-characteristic curve (AUC), sensitivity, specificity, and accuracy values for <sup>18</sup>F-PSMA-1007 PET/CT were 0.9985, 100%, 94.4%, and 97.0%, respectively, whereas those for BS were 0.8507, 71.7%, 88.9%, and 81.0%, respectively. AUC, sensitivity, and accuracy were significantly higher for <sup>18</sup>F-PSMA-1007 PET/CT than for BS (p = 0.00021, p = 0.00087, and p = 0.00018, respectively; McNemar test). <sup>18</sup>F-PSMA-1007 PET/CT detected 527 of the 528 metastatic lesions (99.8%), whereas BS detected 253 (47.9%) (p < 0.0001). The numbers of patients with (a) no bone metastases, (b) oligometastatic disease (1-3 lesions), (c) 4-5 lesions, (d) 6-20 lesions, and (e) > 20 lesions for BS were 13, 21, 0, 8, and 4, respectively, compared with 0, 27, 3, 9, and 7, respectively, on <sup>18</sup>F-PSMA-1007 PET/CT. In addition, <sup>18</sup>F-PSMA-1007 PET/CT detected local recurrence (n = 51), nodal metastases (n = 37), and visceral metastases (n = 4).</p><p><strong>Conclusions: </strong><sup>18</sup>F-PSMA-1007 PET/CT demonstrated higher sensitivity and accuracy than BS for detecting bone metastases in prostate cancer patients.</p>","PeriodicalId":14691,"journal":{"name":"Japanese Journal of Radiology","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2026-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese Journal of Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11604-026-02081-8","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The performance of 18F-labeled prostate-specific membrane antigen (18F-PSMA-1007) positron emission tomography/computed tomography (PET/CT) and bone scintigraphy (BS) for detecting bone metastases in prostate cancer patients was compared.

Materials and methods: One hundred prostate cancer patients (initial staging, n = 9; biochemical recurrence, n = 63; metastatic castration-resistant prostate cancer (mCRPC), n = 15; m0CRPC, n = 13) underwent 18F-PSMA-1007 PET/CT and BS. The patient-, region-, and lesion-based performances of 18F-PSMA-1007 PET/CT and BS for detecting bone metastases were evaluated by experienced readers using a five-point scale.

Results: Bone metastases were identified in 46 (46.0%) patients, 99 (24.8%) of the 400 regions, and 528 lesions. In the analysis, the area under the receiver-operating-characteristic curve (AUC), sensitivity, specificity, and accuracy values for 18F-PSMA-1007 PET/CT were 0.9985, 100%, 94.4%, and 97.0%, respectively, whereas those for BS were 0.8507, 71.7%, 88.9%, and 81.0%, respectively. AUC, sensitivity, and accuracy were significantly higher for 18F-PSMA-1007 PET/CT than for BS (p = 0.00021, p = 0.00087, and p = 0.00018, respectively; McNemar test). 18F-PSMA-1007 PET/CT detected 527 of the 528 metastatic lesions (99.8%), whereas BS detected 253 (47.9%) (p < 0.0001). The numbers of patients with (a) no bone metastases, (b) oligometastatic disease (1-3 lesions), (c) 4-5 lesions, (d) 6-20 lesions, and (e) > 20 lesions for BS were 13, 21, 0, 8, and 4, respectively, compared with 0, 27, 3, 9, and 7, respectively, on 18F-PSMA-1007 PET/CT. In addition, 18F-PSMA-1007 PET/CT detected local recurrence (n = 51), nodal metastases (n = 37), and visceral metastases (n = 4).

Conclusions: 18F-PSMA-1007 PET/CT demonstrated higher sensitivity and accuracy than BS for detecting bone metastases in prostate cancer patients.

18F-PSMA-1007 PET/CT和骨显像对前列腺癌骨转移的诊断准确性。
目的:比较18f标记前列腺特异性膜抗原(18F-PSMA-1007)正电子发射断层扫描/计算机断层扫描(PET/CT)和骨显像(BS)对前列腺癌患者骨转移的检测效果。材料与方法:100例前列腺癌患者(初分期9例,生化复发63例,转移性去雄抵抗性前列腺癌15例;m0CRPC, n = 13)行18F-PSMA-1007 PET/CT和BS检查。18F-PSMA-1007 PET/CT和BS检测骨转移的患者、区域和病变表现由经验丰富的读者使用五分制进行评估。结果:发现骨转移46例(46.0%),400个区域99例(24.8%),528个病灶。18F-PSMA-1007 PET/CT的受者工作特征曲线下面积(AUC)、灵敏度、特异度和准确度分别为0.9985、100%、94.4%和97.0%,BS的受者工作特征曲线下面积、灵敏度、特异度和准确度分别为0.8507、71.7%、88.9%和81.0%。18F-PSMA-1007 PET/CT的AUC、灵敏度和准确性均显著高于BS(分别为p = 0.00021、p = 0.00087和p = 0.00018; McNemar试验)。18F-PSMA-1007 PET/CT检测到528个转移灶中的527个(99.8%),而BS检测到253个(47.9%)(BS的p20病灶分别为13、21、0、8和4个,而18F-PSMA-1007 PET/CT分别为0、27、3、9和7个)。此外,18F-PSMA-1007 PET/CT检出局部复发(n = 51)、淋巴结转移(n = 37)和内脏转移(n = 4)。结论:18F-PSMA-1007 PET/CT检测前列腺癌骨转移的敏感性和准确性均高于BS。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Japanese Journal of Radiology
Japanese Journal of Radiology Medicine-Radiology, Nuclear Medicine and Imaging
自引率
4.80%
发文量
133
期刊介绍: Japanese Journal of Radiology is a peer-reviewed journal, officially published by the Japan Radiological Society. The main purpose of the journal is to provide a forum for the publication of papers documenting recent advances and new developments in the field of radiology in medicine and biology. The scope of Japanese Journal of Radiology encompasses but is not restricted to diagnostic radiology, interventional radiology, radiation oncology, nuclear medicine, radiation physics, and radiation biology. Additionally, the journal covers technical and industrial innovations. The journal welcomes original articles, technical notes, review articles, pictorial essays and letters to the editor. The journal also provides announcements from the boards and the committees of the society. Membership in the Japan Radiological Society is not a prerequisite for submission. Contributions are welcomed from all parts of the world.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书