{"title":"Patient-specific dosimetric impact of online adaptive radiotherapy for locally advanced cervical cancer.","authors":"Jasmine Penney, Krista Chytyk-Praznik","doi":"10.1088/2057-1976/aeb0b0","DOIUrl":null,"url":null,"abstract":"<p><p><i>Background:</i>When cervical cancer patients are treated with external beam radiation therapy, patient-specific anatomical changes, particularly bladder filling, alter the position and shape of the target volume throughout treatment. Online adaptive radiotherapy (oART) accounts for these interfractional changes by generating a treatment plan based on the patient's daily anatomy.<i>Purpose:</i>This study evaluated the dosimetric impact of oART and investigated the relationship between patient-specific anatomical changes and the dosimetric of benefit of adaptation using standard cone-beam CT (CBCT) images for locally advanced cervical cancer (LACC).<i>Methods:</i>Ten patients previously treated for LACC at our institution were identified. A reference treatment plan incorporating a 5 mm clinical target volume (CTV)-to-planning target volume (PTV) margin was generated within the planning system simulator. Three CBCT images (Fractions 1, 13, and 25) were used to retrospectively simulate an adaptive treatment session. For each CBCT, the reference plan was recalculated on the daily anatomy to generate a scheduled plan, and an adapted plan was generated for comparison based on target coverage and organ at risk (OAR) dose metrics. The relationship between interfraction anatomical variation and the dosimetric benefit of adaptation was evaluated.<i>Results:</i>Adapted plans improved target coverage while generally maintaining or reducing OAR dose relative to the scheduled plans. However, the magnitude of benefit from adaptation varied between patients. Moderate associations were observed between interfraction anatomical variation of the bladder volume change and improvements in target coverage.<i>Conclusion:</i>The dosimetric benefit of oART was patient-specific and was partially associated with interfraction anatomical variation. These findings support an individualized approach to identify patient-specific characteristics that may help determine what patients would benefit the most from adaptive radiotherapy.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2026-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/aeb0b0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Background:When cervical cancer patients are treated with external beam radiation therapy, patient-specific anatomical changes, particularly bladder filling, alter the position and shape of the target volume throughout treatment. Online adaptive radiotherapy (oART) accounts for these interfractional changes by generating a treatment plan based on the patient's daily anatomy.Purpose:This study evaluated the dosimetric impact of oART and investigated the relationship between patient-specific anatomical changes and the dosimetric of benefit of adaptation using standard cone-beam CT (CBCT) images for locally advanced cervical cancer (LACC).Methods:Ten patients previously treated for LACC at our institution were identified. A reference treatment plan incorporating a 5 mm clinical target volume (CTV)-to-planning target volume (PTV) margin was generated within the planning system simulator. Three CBCT images (Fractions 1, 13, and 25) were used to retrospectively simulate an adaptive treatment session. For each CBCT, the reference plan was recalculated on the daily anatomy to generate a scheduled plan, and an adapted plan was generated for comparison based on target coverage and organ at risk (OAR) dose metrics. The relationship between interfraction anatomical variation and the dosimetric benefit of adaptation was evaluated.Results:Adapted plans improved target coverage while generally maintaining or reducing OAR dose relative to the scheduled plans. However, the magnitude of benefit from adaptation varied between patients. Moderate associations were observed between interfraction anatomical variation of the bladder volume change and improvements in target coverage.Conclusion:The dosimetric benefit of oART was patient-specific and was partially associated with interfraction anatomical variation. These findings support an individualized approach to identify patient-specific characteristics that may help determine what patients would benefit the most from adaptive radiotherapy.
期刊介绍:
BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.