{"title":"Patient-specific dosimetric impact of online adaptive radiotherapy for locally advanced cervical cancer.","authors":"Jasmine Penney, Krista Chytyk-Praznik","doi":"10.1088/2057-1976/aeb0b0","DOIUrl":null,"url":null,"abstract":"<p><p><i>Background:</i>When cervical cancer patients are treated with external beam radiation therapy, patient-specific anatomical changes, particularly bladder filling, alter the position and shape of the target volume throughout treatment. Online adaptive radiotherapy (oART) accounts for these interfractional changes by generating a treatment plan based on the patient's daily anatomy.<i>Purpose:</i>This study evaluated the dosimetric impact of oART and investigated the relationship between patient-specific anatomical changes and the dosimetric of benefit of adaptation using standard cone-beam CT (CBCT) images for locally advanced cervical cancer (LACC).<i>Methods:</i>Ten patients previously treated for LACC at our institution were identified. A reference treatment plan incorporating a 5 mm clinical target volume (CTV)-to-planning target volume (PTV) margin was generated within the planning system simulator. Three CBCT images (Fractions 1, 13, and 25) were used to retrospectively simulate an adaptive treatment session. For each CBCT, the reference plan was recalculated on the daily anatomy to generate a scheduled plan, and an adapted plan was generated for comparison based on target coverage and organ at risk (OAR) dose metrics. The relationship between interfraction anatomical variation and the dosimetric benefit of adaptation was evaluated.<i>Results:</i>Adapted plans improved target coverage while generally maintaining or reducing OAR dose relative to the scheduled plans. However, the magnitude of benefit from adaptation varied between patients. Moderate associations were observed between interfraction anatomical variation of the bladder volume change and improvements in target coverage.<i>Conclusion:</i>The dosimetric benefit of oART was patient-specific and was partially associated with interfraction anatomical variation. These findings support an individualized approach to identify patient-specific characteristics that may help determine what patients would benefit the most from adaptive radiotherapy.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2026-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/aeb0b0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background:When cervical cancer patients are treated with external beam radiation therapy, patient-specific anatomical changes, particularly bladder filling, alter the position and shape of the target volume throughout treatment. Online adaptive radiotherapy (oART) accounts for these interfractional changes by generating a treatment plan based on the patient's daily anatomy.Purpose:This study evaluated the dosimetric impact of oART and investigated the relationship between patient-specific anatomical changes and the dosimetric of benefit of adaptation using standard cone-beam CT (CBCT) images for locally advanced cervical cancer (LACC).Methods:Ten patients previously treated for LACC at our institution were identified. A reference treatment plan incorporating a 5 mm clinical target volume (CTV)-to-planning target volume (PTV) margin was generated within the planning system simulator. Three CBCT images (Fractions 1, 13, and 25) were used to retrospectively simulate an adaptive treatment session. For each CBCT, the reference plan was recalculated on the daily anatomy to generate a scheduled plan, and an adapted plan was generated for comparison based on target coverage and organ at risk (OAR) dose metrics. The relationship between interfraction anatomical variation and the dosimetric benefit of adaptation was evaluated.Results:Adapted plans improved target coverage while generally maintaining or reducing OAR dose relative to the scheduled plans. However, the magnitude of benefit from adaptation varied between patients. Moderate associations were observed between interfraction anatomical variation of the bladder volume change and improvements in target coverage.Conclusion:The dosimetric benefit of oART was patient-specific and was partially associated with interfraction anatomical variation. These findings support an individualized approach to identify patient-specific characteristics that may help determine what patients would benefit the most from adaptive radiotherapy.

在线适应性放疗对局部晚期宫颈癌患者特异性剂量学的影响。
背景:当宫颈癌患者接受外束放射治疗(EBRT)时,患者特异性解剖改变,特别是膀胱填充,在整个治疗过程中改变靶体积的位置和形状。在线适应性放疗(oART)通过根据患者的日常解剖结构生成治疗计划来解释这些分段间的变化。目的:本研究评估在线适应放疗(oART)的剂量学影响,并利用标准锥束CT (CBCT)图像研究局部晚期宫颈癌(LACC)患者特异性解剖变化与适应剂量学获益之间的关系。方法:选取10例既往在我院治疗过LACC的患者。在计划系统模拟器中生成包含5mm临床靶体积(CTV)与计划靶体积(PTV)余量的参考治疗计划。三张CBCT图像(分数1、13和25)用于回顾性模拟适应性治疗过程。对于每个CBCT,根据每日解剖重新计算参考计划以生成预定计划,并根据靶覆盖和器官危险(OAR)剂量指标生成适应计划进行比较。我们还评估了交叉解剖变异与适应性剂量学效益之间的关系。结果:与预定计划相比,调整后的计划提高了目标覆盖率,同时总体上维持或减少了OAR剂量。然而,适应的获益程度因患者而异。在膀胱体积变化的交叉解剖变异和靶覆盖的改善之间观察到适度的关联。结论:oART的剂量学益处是患者特异性的,部分与交叉解剖变异有关。这些发现支持一种个性化的方法来确定患者的特异性特征,这可能有助于确定哪些患者将从适应性放疗中获益最多。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedical Physics & Engineering Express
Biomedical Physics & Engineering Express RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.80
自引率
0.00%
发文量
153
期刊介绍: BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书