{"title":"Optimization of selected SPECT system parameters for proton range verification: a Monte Carlo study.","authors":"S Gharib, P Taherparvar","doi":"10.1088/2057-1976/aeae43","DOIUrl":null,"url":null,"abstract":"<p><p>This Monte Carlo study investigated a dual-head SPECT-based system for prompt-gamma (PG) range verification in proton therapy, focusing on energy-window and collimator septal thickness effects on PG emission profiles and distal dose fall-off. Using GATE, correlations between PG emissions (4.44, 5.24, 6.13 MeV) and proton depth-dose distributions were evaluated for 90-180 MeV beams in a PMMA phantom. Narrow (4.2-4.6, 5.0-5.4, 5.9-6.3 MeV) and broad (4.2-6.3 MeV) windows were studied. A dual-head SPECT with parallel-hole collimator (1-5 mm septa) was simulated. Image reconstruction was performed with FBP and with OSEM including attenuation correction, using STIR 6.2. The 5.9-6.3 MeV window showed the highest spatial correlation with proton range (Δ ≈1 mm), but its low yield limited applicability. The 4.2-4.6 and 4.2-6.3 MeV windows balanced detection yield and accuracy (Δ ≈2-3 mm). Septal thicknesses ⩾4 mm produced shadowing artefacts, whereas 3 mm gave the most accurate PG localization for the 90 MeV proton beam studied. For the 4.2-4.6 and 4.2-6.3 MeV windows, the PG localization errors (relative to the true PG emission profile) were 1.5 ± 0.5 and 1.4 ± 0.4 mm with FBP, and 1.9 ± 0.3 and 1.7 ± 0.4 mm with OSEM, despite ∼20% lower PG yield than the 1 mm septum. Overall, appropriate window and septal thickness provided PG localization accuracy of 1-2 mm. A 3 mm septum with either the 4.2-4.6 or 4.2-6.3 MeV window offers a favourable trade-off between spatial accuracy and detection efficiency under the 90 MeV condition investigated here, highlighting the potential of optimized SPECT systems for proton range monitoring at this energy.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2026-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/aeae43","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
This Monte Carlo study investigated a dual-head SPECT-based system for prompt-gamma (PG) range verification in proton therapy, focusing on energy-window and collimator septal thickness effects on PG emission profiles and distal dose fall-off. Using GATE, correlations between PG emissions (4.44, 5.24, 6.13 MeV) and proton depth-dose distributions were evaluated for 90-180 MeV beams in a PMMA phantom. Narrow (4.2-4.6, 5.0-5.4, 5.9-6.3 MeV) and broad (4.2-6.3 MeV) windows were studied. A dual-head SPECT with parallel-hole collimator (1-5 mm septa) was simulated. Image reconstruction was performed with FBP and with OSEM including attenuation correction, using STIR 6.2. The 5.9-6.3 MeV window showed the highest spatial correlation with proton range (Δ ≈1 mm), but its low yield limited applicability. The 4.2-4.6 and 4.2-6.3 MeV windows balanced detection yield and accuracy (Δ ≈2-3 mm). Septal thicknesses ⩾4 mm produced shadowing artefacts, whereas 3 mm gave the most accurate PG localization for the 90 MeV proton beam studied. For the 4.2-4.6 and 4.2-6.3 MeV windows, the PG localization errors (relative to the true PG emission profile) were 1.5 ± 0.5 and 1.4 ± 0.4 mm with FBP, and 1.9 ± 0.3 and 1.7 ± 0.4 mm with OSEM, despite ∼20% lower PG yield than the 1 mm septum. Overall, appropriate window and septal thickness provided PG localization accuracy of 1-2 mm. A 3 mm septum with either the 4.2-4.6 or 4.2-6.3 MeV window offers a favourable trade-off between spatial accuracy and detection efficiency under the 90 MeV condition investigated here, highlighting the potential of optimized SPECT systems for proton range monitoring at this energy.
期刊介绍:
BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.