Enhancing the Ultimate Sensitivity of Optical Sensors Based on Passive Ring Resonators Using a PT-Symmetric System of Optically Coupled Active and Closed-Loop Passive Waveguides

IF 0.6 4区 物理与天体物理 Q4 PHYSICS, MULTIDISCIPLINARY
E. V. Shalymov
{"title":"Enhancing the Ultimate Sensitivity of Optical Sensors Based on Passive Ring Resonators Using a PT-Symmetric System of Optically Coupled Active and Closed-Loop Passive Waveguides","authors":"E. V. Shalymov","doi":"10.3103/S1068335626600701","DOIUrl":null,"url":null,"abstract":"<p>This study investigates methods for enhancing the ultimate sensitivity of sensors based on passive ring resonators by utilizing the properties of PT-symmetry. A simple PT-symmetric system is considered, consisting of two parallel waveguides—one providing optical gain and the other introducing optical loss—where the passive waveguide forms part of a ring resonator coupled to the system. This configuration enables an increase in the ultimate sensitivity of sensors based on passive ring resonators. The system can operate in several regimes. The first regime is realized when the gain of the active waveguide does not exceed the coupling coefficient between the parallel waveguides. This regime makes it possible to increase the ultimate sensitivity by more than an order of magnitude—specifically, by a factor of 12 in the example analyzed. The second regime is obtained at an optimal ratio of system parameters. Theoretically, this regime enables an almost unlimited increase in the slope of the transmission coefficient of the system near frequencies lying between the resonator eigenfrequencies, thereby increasing the ultimate sensitivity. However, the amplification of the light passing through the system also increases almost without limit, which may hinder the practical implementation of this regime. Nevertheless, in practice, the use of the second regime can be appropriate when operating the sensor near the resonator eigenfrequencies, where the system does not amplify the transmitted light. In the example in question, this enabled a 76-fold increase in the ultimate sensitivity. The influence of the system parameters on the adjustment of these regimes is also analyzed.</p>","PeriodicalId":503,"journal":{"name":"Bulletin of the Lebedev Physics Institute","volume":"53 3","pages":"S241 - S251"},"PeriodicalIF":0.6000,"publicationDate":"2026-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of the Lebedev Physics Institute","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.3103/S1068335626600701","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

This study investigates methods for enhancing the ultimate sensitivity of sensors based on passive ring resonators by utilizing the properties of PT-symmetry. A simple PT-symmetric system is considered, consisting of two parallel waveguides—one providing optical gain and the other introducing optical loss—where the passive waveguide forms part of a ring resonator coupled to the system. This configuration enables an increase in the ultimate sensitivity of sensors based on passive ring resonators. The system can operate in several regimes. The first regime is realized when the gain of the active waveguide does not exceed the coupling coefficient between the parallel waveguides. This regime makes it possible to increase the ultimate sensitivity by more than an order of magnitude—specifically, by a factor of 12 in the example analyzed. The second regime is obtained at an optimal ratio of system parameters. Theoretically, this regime enables an almost unlimited increase in the slope of the transmission coefficient of the system near frequencies lying between the resonator eigenfrequencies, thereby increasing the ultimate sensitivity. However, the amplification of the light passing through the system also increases almost without limit, which may hinder the practical implementation of this regime. Nevertheless, in practice, the use of the second regime can be appropriate when operating the sensor near the resonator eigenfrequencies, where the system does not amplify the transmitted light. In the example in question, this enabled a 76-fold increase in the ultimate sensitivity. The influence of the system parameters on the adjustment of these regimes is also analyzed.

利用光耦合有源和闭环无源波导的pt对称系统提高无源环形谐振器光传感器的极限灵敏度
本文研究了利用pt对称特性来提高无源环形谐振器传感器极限灵敏度的方法。考虑一个简单的pt对称系统,由两个平行波导组成,一个提供光增益,另一个引入光损耗,其中无源波导形成耦合到系统的环形谐振器的一部分。这种配置可以提高基于无源环形谐振器的传感器的最终灵敏度。该系统可以在几种制度下运行。当有源波导的增益不超过平行波导之间的耦合系数时,可以实现第一种状态。这种状态使得最终灵敏度有可能提高一个数量级以上,具体来说,在所分析的示例中提高了12倍。在系统参数的最优比值下获得了第二个状态。从理论上讲,这种状态使得系统在谐振器本征频率之间的频率附近传输系数的斜率几乎无限增加,从而增加了最终灵敏度。然而,通过系统的光的放大也几乎没有限制地增加,这可能会阻碍该制度的实际实施。然而,在实践中,当在谐振器本征频率附近操作传感器时,系统不会放大透射光时,第二状态的使用是合适的。在这个例子中,这使得最终灵敏度提高了76倍。分析了系统参数对这些状态调整的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Bulletin of the Lebedev Physics Institute
Bulletin of the Lebedev Physics Institute PHYSICS, MULTIDISCIPLINARY-
CiteScore
0.70
自引率
25.00%
发文量
41
审稿时长
6-12 weeks
期刊介绍: Bulletin of the Lebedev Physics Institute is an international peer reviewed journal that publishes results of new original experimental and theoretical studies on all topics of physics: theoretical physics; atomic and molecular physics; nuclear physics; optics; lasers; condensed matter; physics of solids; biophysics, and others.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书