Comparison of deformable image registration algorithms for planning CT and CBCT in prostate cancer patients treated with external beam radiation therapy.

IF 1.6 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Hussam H Jassim, Nooshin Banaee, Hassan Ali Nedaei, Toshikazu Imae
{"title":"Comparison of deformable image registration algorithms for planning CT and CBCT in prostate cancer patients treated with external beam radiation therapy.","authors":"Hussam H Jassim, Nooshin Banaee, Hassan Ali Nedaei, Toshikazu Imae","doi":"10.1007/s12194-026-01143-w","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluated the performance of three categories of deformable image registration (DIR), namely intensity-based, spline-based, and hybrid methods, for planning CT (pCT)-to-cone-beam CT (CBCT) registration to evaluate the accuracy of different DIR approaches for pCT-to-CBCT registration and assess their potential applicability to CBCT-based adaptive radiotherapy. Fourteen default registration methods were compared with the Anatomically Constrained Deformation Algorithm (ANACONDA) using a CIRS phantom and five prostate cancer patients. Registration accuracy was assessed using Target Registration Error (TRE), Dice Similarity Coefficient (DSC), and image quality metrics. Deformed CT (dCT) consistently outperformed CBCT, demonstrating substantial improvements in image quality across Phantom and patient studies. ANACONDA achieved the highest registration accuracy, with TRE < 0.2 cm for prostate landmarks and DSC > 0.90 for target volumes and organs-at-risk. ANACONDA outperformed intensity-based and spline-based registration methods, providing improved image quality and anatomical registration accuracy, thereby facilitating more accurate image guidance for adaptive radiation in pelvic radiotherapy.</p>","PeriodicalId":46252,"journal":{"name":"Radiological Physics and Technology","volume":" ","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2026-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiological Physics and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12194-026-01143-w","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

This study evaluated the performance of three categories of deformable image registration (DIR), namely intensity-based, spline-based, and hybrid methods, for planning CT (pCT)-to-cone-beam CT (CBCT) registration to evaluate the accuracy of different DIR approaches for pCT-to-CBCT registration and assess their potential applicability to CBCT-based adaptive radiotherapy. Fourteen default registration methods were compared with the Anatomically Constrained Deformation Algorithm (ANACONDA) using a CIRS phantom and five prostate cancer patients. Registration accuracy was assessed using Target Registration Error (TRE), Dice Similarity Coefficient (DSC), and image quality metrics. Deformed CT (dCT) consistently outperformed CBCT, demonstrating substantial improvements in image quality across Phantom and patient studies. ANACONDA achieved the highest registration accuracy, with TRE < 0.2 cm for prostate landmarks and DSC > 0.90 for target volumes and organs-at-risk. ANACONDA outperformed intensity-based and spline-based registration methods, providing improved image quality and anatomical registration accuracy, thereby facilitating more accurate image guidance for adaptive radiation in pelvic radiotherapy.

外束放射治疗前列腺癌患者计划CT与CBCT的形变图像配准算法比较。
本研究评估了三类可变形图像配准(DIR)的性能,即基于强度、基于样条和混合方法,用于规划CT (pCT)-锥束CT (CBCT)配准,以评估pCT- CBCT配准的不同DIR方法的准确性,并评估其在基于CBCT的适应性放疗中的潜在适用性。使用CIRS幻影和5例前列腺癌患者,将14种默认配准方法与解剖学约束变形算法(ANACONDA)进行比较。使用目标配准误差(TRE)、骰子相似系数(DSC)和图像质量指标评估配准精度。变形CT (dCT)一直优于CBCT,在幻影和患者研究中显示出图像质量的实质性改善。ANACONDA取得了最高的配准精度,靶体积和高危器官的TRE为0.90。ANACONDA优于基于强度的配准方法和基于样条的配准方法,提高了图像质量和解剖配准精度,从而为盆腔放疗的自适应辐射提供更准确的图像引导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Radiological Physics and Technology
Radiological Physics and Technology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.00
自引率
12.50%
发文量
40
期刊介绍: The purpose of the journal Radiological Physics and Technology is to provide a forum for sharing new knowledge related to research and development in radiological science and technology, including medical physics and radiological technology in diagnostic radiology, nuclear medicine, and radiation therapy among many other radiological disciplines, as well as to contribute to progress and improvement in medical practice and patient health care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书