{"title":"Sutureless Aortic Valve Replacement as a Bailout Strategy for Type A Aortic Dissection: 2 Case Reports.","authors":"Sahri Kim, Joon Bum Kim","doi":"10.5090/jcs.26.096","DOIUrl":null,"url":null,"abstract":"<p><p>Sutureless aortic valve replacement (AVR) is generally avoided in type A aortic dissection (TAAD) because fragile, dissected tissue may provide inadequate stent fixation. We describe 2 patients with TAAD in whom a Perceval Plus sutureless bioprosthesis was successfully deployed as a bailout after failed aortic valve repair. In both cases, prior ascending aortic replacement created a stable prosthetic landing zone that allowed reliable radial fixation. Conversion to sutureless AVR increased aortic cross-clamp time by only 20-23 minutes, approximately half the time required for conventional sutured implantation. Postoperative imaging showed appropriate valve positioning without paravalvular leakage, and hemodynamic function remained stable at 7 and 8 months. Sutureless AVR may therefore offer a viable, time-saving bailout strategy for selected patients with TAAD, an intact aortic annulus, and a stabilized proximal aorta.</p>","PeriodicalId":34499,"journal":{"name":"Journal of Chest Surgery","volume":" ","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2026-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chest Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5090/jcs.26.096","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Sutureless aortic valve replacement (AVR) is generally avoided in type A aortic dissection (TAAD) because fragile, dissected tissue may provide inadequate stent fixation. We describe 2 patients with TAAD in whom a Perceval Plus sutureless bioprosthesis was successfully deployed as a bailout after failed aortic valve repair. In both cases, prior ascending aortic replacement created a stable prosthetic landing zone that allowed reliable radial fixation. Conversion to sutureless AVR increased aortic cross-clamp time by only 20-23 minutes, approximately half the time required for conventional sutured implantation. Postoperative imaging showed appropriate valve positioning without paravalvular leakage, and hemodynamic function remained stable at 7 and 8 months. Sutureless AVR may therefore offer a viable, time-saving bailout strategy for selected patients with TAAD, an intact aortic annulus, and a stabilized proximal aorta.