Chaochao Zhang, Yingxin Dai, Dan Cao, Rong Chen, Zhiyuan Gao, Yifan Gong, Anni Guo, Xiaowei Huang, Aiping Liu, Tiantian Liu, Ce Shi, Yi Sun, Wenjuan Wang, Hongkun Wu, Jing Yang, Yiwen Yao, Lei Yu, Ying Zhang, Haiyin Zheng, Kaimin Mao, Min Li, Bing Zheng
{"title":"An LR-based risk stratification framework for assessing interlaboratory variability in HEp-2 IFA pattern interpretation.","authors":"Chaochao Zhang, Yingxin Dai, Dan Cao, Rong Chen, Zhiyuan Gao, Yifan Gong, Anni Guo, Xiaowei Huang, Aiping Liu, Tiantian Liu, Ce Shi, Yi Sun, Wenjuan Wang, Hongkun Wu, Jing Yang, Yiwen Yao, Lei Yu, Ying Zhang, Haiyin Zheng, Kaimin Mao, Min Li, Bing Zheng","doi":"10.1515/cclm-2026-1012","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Interlaboratory variability in HEp-2 indirect immunofluorescence assay (IFA) interpretation remains a major challenge. Conventional agreement metrics quantify disagreement but do not distinguish discrepancies by diagnostic relevance. We aimed to develop a likelihood ratio (LR)-based framework for clinically informed assessment of interpretation variability.</p><p><strong>Methods: </strong>Pattern-specific positive LRs were derived from 33,690 routine HEp-2 IFA records and used to classify patterns into four risk tiers. A pattern discrepancy score (PDS) was developed to quantify discrepancies according to risk-tier displacement. Interlaboratory variability was assessed using a standardized 200-specimen panel tested by 18 laboratories, and diagnostic performance was explored in six laboratories.</p><p><strong>Results: </strong>Pattern disagreement rates ranged from 17.5 to 50.0 %. PDS strongly correlated with disagreement rate (Spearman's ρ=0.936, p<0.001), but laboratories with similar disagreement rates differed in cross-tier discrepancy distribution. Most discrepancies remained within the same risk tier; among discordant interpretations involving high-risk reference patterns, 20.4 % crossed into another tier. Pattern concordance varied markedly, while titer agreement was moderate to almost perfect (weighted κ, 0.569-0.821). Across six laboratories, diagnostic performance varied (Youden Index, 0.391-0.617), but was not significantly associated with interpretation consistency.</p><p><strong>Conclusions: </strong>HEp-2 IFA interpretation variability differs in both frequency and potential diagnostic relevance. The LR-based framework and PDS complement conventional agreement measures by identifying discrepancies that alter diagnostic risk classification, potentially supporting risk-oriented proficiency assessment and targeted quality improvement.</p>","PeriodicalId":10390,"journal":{"name":"Clinical chemistry and laboratory medicine","volume":" ","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical chemistry and laboratory medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/cclm-2026-1012","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: Interlaboratory variability in HEp-2 indirect immunofluorescence assay (IFA) interpretation remains a major challenge. Conventional agreement metrics quantify disagreement but do not distinguish discrepancies by diagnostic relevance. We aimed to develop a likelihood ratio (LR)-based framework for clinically informed assessment of interpretation variability.
Methods: Pattern-specific positive LRs were derived from 33,690 routine HEp-2 IFA records and used to classify patterns into four risk tiers. A pattern discrepancy score (PDS) was developed to quantify discrepancies according to risk-tier displacement. Interlaboratory variability was assessed using a standardized 200-specimen panel tested by 18 laboratories, and diagnostic performance was explored in six laboratories.
Results: Pattern disagreement rates ranged from 17.5 to 50.0 %. PDS strongly correlated with disagreement rate (Spearman's ρ=0.936, p<0.001), but laboratories with similar disagreement rates differed in cross-tier discrepancy distribution. Most discrepancies remained within the same risk tier; among discordant interpretations involving high-risk reference patterns, 20.4 % crossed into another tier. Pattern concordance varied markedly, while titer agreement was moderate to almost perfect (weighted κ, 0.569-0.821). Across six laboratories, diagnostic performance varied (Youden Index, 0.391-0.617), but was not significantly associated with interpretation consistency.
Conclusions: HEp-2 IFA interpretation variability differs in both frequency and potential diagnostic relevance. The LR-based framework and PDS complement conventional agreement measures by identifying discrepancies that alter diagnostic risk classification, potentially supporting risk-oriented proficiency assessment and targeted quality improvement.
期刊介绍:
Clinical Chemistry and Laboratory Medicine (CCLM) publishes articles on novel teaching and training methods applicable to laboratory medicine. CCLM welcomes contributions on the progress in fundamental and applied research and cutting-edge clinical laboratory medicine. It is one of the leading journals in the field, with an impact factor over 3. CCLM is issued monthly, and it is published in print and electronically.
CCLM is the official journal of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and publishes regularly EFLM recommendations and news. CCLM is the official journal of the National Societies from Austria (ÖGLMKC); Belgium (RBSLM); Germany (DGKL); Hungary (MLDT); Ireland (ACBI); Italy (SIBioC); Portugal (SPML); and Slovenia (SZKK); and it is affiliated to AACB (Australia) and SFBC (France).
Topics:
- clinical biochemistry
- clinical genomics and molecular biology
- clinical haematology and coagulation
- clinical immunology and autoimmunity
- clinical microbiology
- drug monitoring and analysis
- evaluation of diagnostic biomarkers
- disease-oriented topics (cardiovascular disease, cancer diagnostics, diabetes)
- new reagents, instrumentation and technologies
- new methodologies
- reference materials and methods
- reference values and decision limits
- quality and safety in laboratory medicine
- translational laboratory medicine
- clinical metrology
Follow @cclm_degruyter on Twitter!