Clinical performance and practical implications of continuous glucose monitoring in very preterm infants: a cohort study.

IF 3.5 2区 医学 Q1 PEDIATRICS
Gordon Xin Hua Liu, Loredana Marcovecchio, Kathryn Beardsall
{"title":"Clinical performance and practical implications of continuous glucose monitoring in very preterm infants: a cohort study.","authors":"Gordon Xin Hua Liu, Loredana Marcovecchio, Kathryn Beardsall","doi":"10.1136/archdischild-2026-330804","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To explore the clinical performance of continuous glucose monitoring (CGM) in very preterm infants during the first week of life, using data from the multicentre Real time continuous glucose monitoring (REACT) randomised controlled trial (RCT) and to consider how CGM can best support neonatal glucose management.</p><p><strong>Design: </strong>Prespecified secondary analysis of paired sensor glucose (SG) and blood glucose (BG) measurements from the REACT RCT.</p><p><strong>Setting: </strong>13 neonatal intensive care units (NICUs) in the UK, Spain and the Netherlands.</p><p><strong>Patients: </strong>155 very preterm infants (≤1200 g birth weight or <34 weeks' gestation) with CGM data collected during the first week of life.</p><p><strong>Main outcome measures: </strong>Mean absolute relative difference (MARD), ISO 15197:2013 system agreement, Bland-Altman bias, error grid analysis and clinical contextualisation of CGM performance.</p><p><strong>Results: </strong>Across 2223 SG-BG pairs, overall MARD was 11.9%, and 98%-99% of values fell within clinically acceptable error grid zones. SG tended to be less accurate at BG extremes, although error grid analyses show that clinical risk from discrepancies was low. CGM detected episodes of dysglycaemia not captured by intermittent sampling. Glucose variability did not materially influence accuracy.</p><p><strong>Conclusions: </strong>CGM can provide clinically meaningful information in very preterm infants despite modest analytical inaccuracy when compared with single point-of-care values. Its greatest utility lies in continuous trend monitoring, early detection of silent dysglycaemia and reduced invasive sampling, rather than replacement of diagnostic blood testing. Clinicians should interpret SG values in context, confirm unexpected extremes with BG and focus on patterns rather than single values.</p>","PeriodicalId":8177,"journal":{"name":"Archives of Disease in Childhood - Fetal and Neonatal Edition","volume":" ","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2026-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Disease in Childhood - Fetal and Neonatal Edition","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/archdischild-2026-330804","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To explore the clinical performance of continuous glucose monitoring (CGM) in very preterm infants during the first week of life, using data from the multicentre Real time continuous glucose monitoring (REACT) randomised controlled trial (RCT) and to consider how CGM can best support neonatal glucose management.

Design: Prespecified secondary analysis of paired sensor glucose (SG) and blood glucose (BG) measurements from the REACT RCT.

Setting: 13 neonatal intensive care units (NICUs) in the UK, Spain and the Netherlands.

Patients: 155 very preterm infants (≤1200 g birth weight or <34 weeks' gestation) with CGM data collected during the first week of life.

Main outcome measures: Mean absolute relative difference (MARD), ISO 15197:2013 system agreement, Bland-Altman bias, error grid analysis and clinical contextualisation of CGM performance.

Results: Across 2223 SG-BG pairs, overall MARD was 11.9%, and 98%-99% of values fell within clinically acceptable error grid zones. SG tended to be less accurate at BG extremes, although error grid analyses show that clinical risk from discrepancies was low. CGM detected episodes of dysglycaemia not captured by intermittent sampling. Glucose variability did not materially influence accuracy.

Conclusions: CGM can provide clinically meaningful information in very preterm infants despite modest analytical inaccuracy when compared with single point-of-care values. Its greatest utility lies in continuous trend monitoring, early detection of silent dysglycaemia and reduced invasive sampling, rather than replacement of diagnostic blood testing. Clinicians should interpret SG values in context, confirm unexpected extremes with BG and focus on patterns rather than single values.

非常早产儿连续血糖监测的临床表现和实际意义:一项队列研究。
目的:利用多中心实时连续血糖监测(REACT)随机对照试验(RCT)的数据,探讨连续血糖监测(CGM)在早产儿出生后第一周的临床表现,并探讨CGM如何最好地支持新生儿血糖管理。设计:对REACT RCT的配对传感器葡萄糖(SG)和血糖(BG)测量值进行预先指定的二次分析。环境:英国、西班牙和荷兰的13个新生儿重症监护病房(NICUs)。主要结局指标:平均绝对相对差(MARD)、ISO 15197:2013系统一致性、Bland-Altman偏倚、误差网格分析和CGM表现的临床背景化。结果:在2223对SG-BG中,总体MARD为11.9%,98%-99%的值落在临床可接受的误差网格范围内。尽管误差网格分析显示差异的临床风险很低,但SG在BG极端情况下往往不太准确。CGM检测到间歇性采样未捕获的血糖异常发作。血糖变异性对准确度没有实质性影响。结论:CGM可以为极早产儿提供有临床意义的信息,尽管与单点护理值相比存在一定的分析不准确性。其最大的效用在于持续监测趋势,早期发现无症状血糖异常,减少侵入性采样,而不是替代诊断性血液检测。临床医生应根据具体情况解释SG值,确认BG的意外极端值,并关注模式而不是单一值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
9.00
自引率
4.50%
发文量
90
审稿时长
6-12 weeks
期刊介绍: Archives of Disease in Childhood is an international peer review journal that aims to keep paediatricians and others up to date with advances in the diagnosis and treatment of childhood diseases as well as advocacy issues such as child protection. It focuses on all aspects of child health and disease from the perinatal period (in the Fetal and Neonatal edition) through to adolescence. ADC includes original research reports, commentaries, reviews of clinical and policy issues, and evidence reports. Areas covered include: community child health, public health, epidemiology, acute paediatrics, advocacy, and ethics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书