Metabolic alterations in pneumonia assessed by breath analysis: an exploratory paired longitudinal study comparing acute infection and post-recovery states.
Britta C Brugger, Noriane A Sievi, Sarah Basler, Patrick Baumgartner, Jonas Herth, Felix Schmidt, Kapil Dev Singh, Pablo Sinues, Malcolm Kohler
{"title":"Metabolic alterations in pneumonia assessed by breath analysis: an exploratory paired longitudinal study comparing acute infection and post-recovery states.","authors":"Britta C Brugger, Noriane A Sievi, Sarah Basler, Patrick Baumgartner, Jonas Herth, Felix Schmidt, Kapil Dev Singh, Pablo Sinues, Malcolm Kohler","doi":"10.1088/1752-7163/aead14","DOIUrl":null,"url":null,"abstract":"<p><p>The diagnosis and monitoring of pneumonia remain a challenge due to its diverse etiology, overlapping clinical symptoms with other respiratory infections, and limitations in current diagnostic technologies for timely and accurate detection. We evaluated whether real-time secondary electrospray ionization-high-resolution mass spectrometry breathomics can capture pneumonia-associated breath-profile changes in a paired longitudinal cohort. In this single-center longitudinal study at University Hospital Zurich, Switzerland, adults with clinically confirmed pneumonia (<i>n</i>= 47, median age: 63) were enrolled between 2020 and 2023 sampled during acute infection and again after recovery (median interval 85 d). After pre-processing, 3635 mass-spectral features were retained across ion modes, and 1498 could be linked to at least one human metabolome database (HMDB) entry by accurate-mass matching (±1 ppm). Breath profiles were assessed using a subject-grouped, nested cross-validated partial least squares discriminate analysis (PLS-DA) and paired differential analysis. PLS-DA showed framework moderate exploratory internal discrimination between pneumonia and post-pneumonia measurements with moderate performance (median balanced accuracy 0.72; median AUROC 0.80;<i>Q</i><sup>2</sup>0.24; two latent variables), with a permutation<i>p</i>-value of 0.112. Paired differential analysis identified 104 recovery-associated features (58 higher and 46 lower during pneumonia) meeting |mean log<sub>2</sub>fold change| ⩾ 1 and FDR<i>q</i>⩽ 0.05, with putative accurate-mass matches to 239 HMDB accessions. Real-time breathomics captures reproducible changes in exhaled breath mass-spectral profiles from pneumonia to convalescence and reveals breath-profile heterogeneity not fully reflected by standard clinical indices. These results should be interpreted as exploratory and hypothesis-generating, motivating multicenter validation with tandem mass spectrometry-supported compound identification, clinically relevant control groups, and longitudinal outcome linkage.</p>","PeriodicalId":15306,"journal":{"name":"Journal of breath research","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2026-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of breath research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1088/1752-7163/aead14","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
The diagnosis and monitoring of pneumonia remain a challenge due to its diverse etiology, overlapping clinical symptoms with other respiratory infections, and limitations in current diagnostic technologies for timely and accurate detection. We evaluated whether real-time secondary electrospray ionization-high-resolution mass spectrometry breathomics can capture pneumonia-associated breath-profile changes in a paired longitudinal cohort. In this single-center longitudinal study at University Hospital Zurich, Switzerland, adults with clinically confirmed pneumonia (n= 47, median age: 63) were enrolled between 2020 and 2023 sampled during acute infection and again after recovery (median interval 85 d). After pre-processing, 3635 mass-spectral features were retained across ion modes, and 1498 could be linked to at least one human metabolome database (HMDB) entry by accurate-mass matching (±1 ppm). Breath profiles were assessed using a subject-grouped, nested cross-validated partial least squares discriminate analysis (PLS-DA) and paired differential analysis. PLS-DA showed framework moderate exploratory internal discrimination between pneumonia and post-pneumonia measurements with moderate performance (median balanced accuracy 0.72; median AUROC 0.80;Q20.24; two latent variables), with a permutationp-value of 0.112. Paired differential analysis identified 104 recovery-associated features (58 higher and 46 lower during pneumonia) meeting |mean log2fold change| ⩾ 1 and FDRq⩽ 0.05, with putative accurate-mass matches to 239 HMDB accessions. Real-time breathomics captures reproducible changes in exhaled breath mass-spectral profiles from pneumonia to convalescence and reveals breath-profile heterogeneity not fully reflected by standard clinical indices. These results should be interpreted as exploratory and hypothesis-generating, motivating multicenter validation with tandem mass spectrometry-supported compound identification, clinically relevant control groups, and longitudinal outcome linkage.
期刊介绍:
Journal of Breath Research is dedicated to all aspects of scientific breath research. The traditional focus is on analysis of volatile compounds and aerosols in exhaled breath for the investigation of exogenous exposures, metabolism, toxicology, health status and the diagnosis of disease and breath odours. The journal also welcomes other breath-related topics.
Typical areas of interest include:
Big laboratory instrumentation: describing new state-of-the-art analytical instrumentation capable of performing high-resolution discovery and targeted breath research; exploiting complex technologies drawn from other areas of biochemistry and genetics for breath research.
Engineering solutions: developing new breath sampling technologies for condensate and aerosols, for chemical and optical sensors, for extraction and sample preparation methods, for automation and standardization, and for multiplex analyses to preserve the breath matrix and facilitating analytical throughput. Measure exhaled constituents (e.g. CO2, acetone, isoprene) as markers of human presence or mitigate such contaminants in enclosed environments.
Human and animal in vivo studies: decoding the ''breath exposome'', implementing exposure and intervention studies, performing cross-sectional and case-control research, assaying immune and inflammatory response, and testing mammalian host response to infections and exogenous exposures to develop information directly applicable to systems biology. Studying inhalation toxicology; inhaled breath as a source of internal dose; resultant blood, breath and urinary biomarkers linked to inhalation pathway.
Cellular and molecular level in vitro studies.
Clinical, pharmacological and forensic applications.
Mathematical, statistical and graphical data interpretation.