{"title":"Application of synthetic computed tomography based on a deep learning model in pelvic radiotherapy planning: A feasibility study.","authors":"Feng Lin, Jinyan Hu, Zhao Li, Jun Wang, Wenying Zhang, Aiping Wen, Mao Li, Yunfei Hu, Yang Wang","doi":"10.1002/acm2.70829","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>While computed tomography (CT) remains an important imaging modality in radiotherapy planning, magnetic resonance imaging (MRI)-only workflow, often realized via the generation of synthetic computed tomography (sCT), is desired due to superior soft-tissue contrast and less susceptibility to registration errors.</p><p><strong>Purpose: </strong>The aim of this study was to investigate the feasibility of applying sCT, generated from MRI using a deep learning model, to pelvic radiotherapy planning. By comparing differences between conventional CT and sCT in terms of image quality, dosimetric parameters, and three-dimensional (3D) dose distributions, the clinical potential of an MRI-only radiotherapy workflow was evaluated.</p><p><strong>Methods: </strong>Fifteen patients who underwent both pelvic CT and MRI examinations were retrospectively enrolled. For the same patients, sCT images were generated from the MRI using a pretrained pelvic deep learning model integrated in the syngo.via VB60A software platform. Treatment plans originally created on planning CT (pCT) images were re-calculated on corresponding sCT datasets. Subsequently, the mean absolute error (MAE) of CT numbers, Dice similarity coefficients (DSCs) for major structures, dose-volume histogram (DVH) parameters for the planning target volume (PTV) and major organs at risk (OARs), and 3D dose distributions were compared between plans calculated on pCT and sCT.</p><p><strong>Results: </strong>In terms of image quality, sCT demonstrated comparable CT number accuracy with pCT for soft tissue structures, with MAEs ranging from 6.8 to 8.5 Hounsfield units (HU) for the PTV, bladder, and rectum. Higher MAEs were observed for bony structures (femoral heads and bone marrow), with average MAEs ranging between 17 and 19 HU. The DSC was 0.94 ± 0.01 for the right femoral head, 0.93 ± 0.01 for the left femoral head, and 0.85 ± 0.03 for bone marrow. Regarding dosimetric comparison, the mean absolute differences in key dosimetric parameters for the PTV (D98%, D95%, and Dmean) were all below 0.6%, remaining within clinically acceptable limits. Among the OARs, except for relatively large differences for the maximum and minimum doses in the bladder, the mean dose (Dmean) differences for the rectum, femoral heads, and bone marrow were minimal (mean absolute value ≤ 0.34%), indicating high reliability. Analysis of 3D dose distributions using a 2% 2 mm γ criterion revealed an average γ passing rate of 95.92% between sCT and pCT, satisfying routine clinical quality assurance requirements.</p><p><strong>Conclusions: </strong>The findings of our study demonstrate the feasibility of applying sCT generated from MRI using a deep learning model to pelvic radiotherapy planning. The MRI-only workflow proposed on this basis eliminates systematic errors introduced by CT-MRI image registration, optimizes the clinical workflow, and fully exploits the superior soft-tissue contrast of MRI to improve target delineation accuracy. The proposed approach provides a novel technical paradigm for achieving more precise and efficient individualized radiotherapy.</p>","PeriodicalId":14989,"journal":{"name":"Journal of Applied Clinical Medical Physics","volume":"27 10","pages":"e70829"},"PeriodicalIF":2.5000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13619458/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Clinical Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/acm2.70829","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Background: While computed tomography (CT) remains an important imaging modality in radiotherapy planning, magnetic resonance imaging (MRI)-only workflow, often realized via the generation of synthetic computed tomography (sCT), is desired due to superior soft-tissue contrast and less susceptibility to registration errors.
Purpose: The aim of this study was to investigate the feasibility of applying sCT, generated from MRI using a deep learning model, to pelvic radiotherapy planning. By comparing differences between conventional CT and sCT in terms of image quality, dosimetric parameters, and three-dimensional (3D) dose distributions, the clinical potential of an MRI-only radiotherapy workflow was evaluated.
Methods: Fifteen patients who underwent both pelvic CT and MRI examinations were retrospectively enrolled. For the same patients, sCT images were generated from the MRI using a pretrained pelvic deep learning model integrated in the syngo.via VB60A software platform. Treatment plans originally created on planning CT (pCT) images were re-calculated on corresponding sCT datasets. Subsequently, the mean absolute error (MAE) of CT numbers, Dice similarity coefficients (DSCs) for major structures, dose-volume histogram (DVH) parameters for the planning target volume (PTV) and major organs at risk (OARs), and 3D dose distributions were compared between plans calculated on pCT and sCT.
Results: In terms of image quality, sCT demonstrated comparable CT number accuracy with pCT for soft tissue structures, with MAEs ranging from 6.8 to 8.5 Hounsfield units (HU) for the PTV, bladder, and rectum. Higher MAEs were observed for bony structures (femoral heads and bone marrow), with average MAEs ranging between 17 and 19 HU. The DSC was 0.94 ± 0.01 for the right femoral head, 0.93 ± 0.01 for the left femoral head, and 0.85 ± 0.03 for bone marrow. Regarding dosimetric comparison, the mean absolute differences in key dosimetric parameters for the PTV (D98%, D95%, and Dmean) were all below 0.6%, remaining within clinically acceptable limits. Among the OARs, except for relatively large differences for the maximum and minimum doses in the bladder, the mean dose (Dmean) differences for the rectum, femoral heads, and bone marrow were minimal (mean absolute value ≤ 0.34%), indicating high reliability. Analysis of 3D dose distributions using a 2% 2 mm γ criterion revealed an average γ passing rate of 95.92% between sCT and pCT, satisfying routine clinical quality assurance requirements.
Conclusions: The findings of our study demonstrate the feasibility of applying sCT generated from MRI using a deep learning model to pelvic radiotherapy planning. The MRI-only workflow proposed on this basis eliminates systematic errors introduced by CT-MRI image registration, optimizes the clinical workflow, and fully exploits the superior soft-tissue contrast of MRI to improve target delineation accuracy. The proposed approach provides a novel technical paradigm for achieving more precise and efficient individualized radiotherapy.
期刊介绍:
Journal of Applied Clinical Medical Physics is an international Open Access publication dedicated to clinical medical physics. JACMP welcomes original contributions dealing with all aspects of medical physics from scientists working in the clinical medical physics around the world. JACMP accepts only online submission.
JACMP will publish:
-Original Contributions: Peer-reviewed, investigations that represent new and significant contributions to the field. Recommended word count: up to 7500.
-Review Articles: Reviews of major areas or sub-areas in the field of clinical medical physics. These articles may be of any length and are peer reviewed.
-Technical Notes: These should be no longer than 3000 words, including key references.
-Letters to the Editor: Comments on papers published in JACMP or on any other matters of interest to clinical medical physics. These should not be more than 1250 (including the literature) and their publication is only based on the decision of the editor, who occasionally asks experts on the merit of the contents.
-Book Reviews: The editorial office solicits Book Reviews.
-Announcements of Forthcoming Meetings: The Editor may provide notice of forthcoming meetings, course offerings, and other events relevant to clinical medical physics.
-Parallel Opposed Editorial: We welcome topics relevant to clinical practice and medical physics profession. The contents can be controversial debate or opposed aspects of an issue. One author argues for the position and the other against. Each side of the debate contains an opening statement up to 800 words, followed by a rebuttal up to 500 words. Readers interested in participating in this series should contact the moderator with a proposed title and a short description of the topic