Validation of Cardiorespiratory-Gated Proton Beam Delivery for Stereotactic Arrhythmia Radioablation.

IF 2.4 3区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Journal of Cardiovascular Electrophysiology Pub Date : 2026-10-01 Epub Date: 2026-09-27 DOI:10.1111/jce.70512
Jagdip Kang, Felicitas J Bijari, Yanis Chemli, Yen-Lin Chen, Helen Deng, Nicolas Depauw, Maeva Dhaynaut, Adriano Garonna, Hyeongseok Kim, Marina Macdonald-Soccorso, Sung-Hyun Moon, Marc D Normandin, Rebecca Woodcock, K Moshe Yaghoubian, Georges El Fakhri, Robert Levine, Kyung-Wook Jee, H Immo Lehmann
{"title":"Validation of Cardiorespiratory-Gated Proton Beam Delivery for Stereotactic Arrhythmia Radioablation.","authors":"Jagdip Kang, Felicitas J Bijari, Yanis Chemli, Yen-Lin Chen, Helen Deng, Nicolas Depauw, Maeva Dhaynaut, Adriano Garonna, Hyeongseok Kim, Marina Macdonald-Soccorso, Sung-Hyun Moon, Marc D Normandin, Rebecca Woodcock, K Moshe Yaghoubian, Georges El Fakhri, Robert Levine, Kyung-Wook Jee, H Immo Lehmann","doi":"10.1111/jce.70512","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Stereotactic arrhythmia radioablation (STAR) is a promising noninvasive therapy for refractory ventricular tachycardia. Using scanned proton beams for STAR enables precisely focused, high doses of ionizing radiation. Effective mitigation of target motion is critical for safety but remains challenging due to the complex interplay between beam scanning and cardiorespiratory motion. We evaluated the safety and feasibility of accurately delivering gated scanned proton beams to a ventricular myocardial target and compared lesion outcomes of respiratory (single)- and cardiorespiratory (dual)-gated proton beams.</p><p><strong>Methods: </strong>Six pigs (the first two used as a test of the protocol) underwent baseline CT for treatment planning with a single fractional dose of 35 Gy to a myocardial target in the left ventricular free wall. They were subsequently treated with either single- or dual-gated delivery using scanned proton beams. Treatment response was evaluated by echocardiography, blood analysis and positron emission tomography (PET)-CT at baseline and 14-15 weeks after irradiation. Lesions were assessed at termination, and tissues were harvested for histopathology.</p><p><strong>Results: </strong>Average target expansion for intrafractional motion was lower with dual compared to single gating (16%-23% vs. 48%-72%, N = 2 in each arm). The irradiated area was distinguishable in vivo on PET-CT and ex vivo in necropsy at the expected location in all animals. Visual lesion transmurality was confirmed by histology. Lesion sizes were not far from the expected volumes in dual-gated animals but were larger in single-gated animals (p = 0.3 for between-group comparison, N = 2 in each arm).</p><p><strong>Conclusions: </strong>The results confirmed the feasibility of the workflow. Dual-gated irradiation was associated with reduced radiation exposure of the myocardium outside the target volume, and with lesion sizes closer to those planned.</p>","PeriodicalId":15178,"journal":{"name":"Journal of Cardiovascular Electrophysiology","volume":" ","pages":"2375-2384"},"PeriodicalIF":2.4000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13661793/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jce.70512","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/27 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: Stereotactic arrhythmia radioablation (STAR) is a promising noninvasive therapy for refractory ventricular tachycardia. Using scanned proton beams for STAR enables precisely focused, high doses of ionizing radiation. Effective mitigation of target motion is critical for safety but remains challenging due to the complex interplay between beam scanning and cardiorespiratory motion. We evaluated the safety and feasibility of accurately delivering gated scanned proton beams to a ventricular myocardial target and compared lesion outcomes of respiratory (single)- and cardiorespiratory (dual)-gated proton beams.

Methods: Six pigs (the first two used as a test of the protocol) underwent baseline CT for treatment planning with a single fractional dose of 35 Gy to a myocardial target in the left ventricular free wall. They were subsequently treated with either single- or dual-gated delivery using scanned proton beams. Treatment response was evaluated by echocardiography, blood analysis and positron emission tomography (PET)-CT at baseline and 14-15 weeks after irradiation. Lesions were assessed at termination, and tissues were harvested for histopathology.

Results: Average target expansion for intrafractional motion was lower with dual compared to single gating (16%-23% vs. 48%-72%, N = 2 in each arm). The irradiated area was distinguishable in vivo on PET-CT and ex vivo in necropsy at the expected location in all animals. Visual lesion transmurality was confirmed by histology. Lesion sizes were not far from the expected volumes in dual-gated animals but were larger in single-gated animals (p = 0.3 for between-group comparison, N = 2 in each arm).

Conclusions: The results confirmed the feasibility of the workflow. Dual-gated irradiation was associated with reduced radiation exposure of the myocardium outside the target volume, and with lesion sizes closer to those planned.

心肺门控质子束放射治疗立体定向心律失常的有效性验证。
目的:立体定向心律失常放射消融术(STAR)是一种治疗难治性室性心动过速的无创治疗方法。使用扫描的质子束进行STAR可以实现精确聚焦,高剂量的电离辐射。有效减缓目标运动对安全至关重要,但由于束扫描和心肺运动之间复杂的相互作用,仍然具有挑战性。我们评估了将门控扫描的质子束精确输送到心室心肌目标的安全性和可行性,并比较了呼吸(单)门控和心肺(双)门控质子束的病变结果。方法:6头猪(前2头作为试验方案)接受基线CT检查,对左心室游离壁心肌靶进行单次剂量35gy的治疗计划。他们随后使用扫描质子束进行单门或双门递送治疗。在基线和照射后14-15周,通过超声心动图、血液分析和正电子发射断层扫描(PET)-CT评估治疗效果。在终止时评估病变,并收集组织进行组织病理学检查。结果:与单门控相比,双门控的平均靶扩张率较低(16%-23%比48%-72%,每组N = 2)。所有动物的活体PET-CT和离体尸检在预期位置上均可区分辐照区域。组织学证实视觉病变为跨壁性。双门动物的病变大小与预期体积相差不大,而单门动物的病变大小更大(组间比较p = 0.3,每组N = 2)。结论:实验结果证实了该工作流程的可行性。双门辐照可减少靶体积外心肌的辐射暴露,并使病变大小更接近计划大小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.20
自引率
14.80%
发文量
433
审稿时长
3-6 weeks
期刊介绍: Journal of Cardiovascular Electrophysiology (JCE) keeps its readership well informed of the latest developments in the study and management of arrhythmic disorders. Edited by Bradley P. Knight, M.D., and a distinguished international editorial board, JCE is the leading journal devoted to the study of the electrophysiology of the heart.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书