Clinical commissioning of a commercial brass GRID collimator for spatially fractionated radiotherapy.

IF 1.7 4区 医学 Q4 ONCOLOGY
Ravindra Yaparpalvi, Dinesh K Mynampati, Madhur K Garg, Wolfgang A Tomé
{"title":"Clinical commissioning of a commercial brass GRID collimator for spatially fractionated radiotherapy.","authors":"Ravindra Yaparpalvi, Dinesh K Mynampati, Madhur K Garg, Wolfgang A Tomé","doi":"10.1016/j.meddos.2026.08.006","DOIUrl":null,"url":null,"abstract":"<p><p>Spatially Fractionated Radiation Therapy (SFRT) delivers high-dose radiation in a GRID pattern to treat large tumors. This can be achieved using either a physical GRID block or virtual MLC-based patterns. This report presents our experience commissioning a commercial brass GRID collimator for SFRT. Commissioning was performed using a brass GRID collimator with 6 MV and 10 MV photon beams under both flattening filter (FF) and flattening filter-free (FFF) configurations. Dosimetric measurements were collected in a water phantom and compared with treatment planning system calculations. SFRT test plans were created and validated using a commercial detector array. Valley-to-peak dose ratio (VPDR) ranged from 0.20 to 0.30 (6-MV) and 0.30 to 0.37 (10-MV). The Percent depth doses were lower than those for open fields at all beam energies. Measured vs. calculated profiles agreed within ±5% in dose and 1 mm in distance for all beam energies. TPS-generated plans showed strong agreement with measured distributions, with an average gamma passing rate of 96.5% (3%/3 mm criteria). We successfully commissioned and validated a commercial GRID collimator for SFRT using 6-MV and 10-MV photon beams in both FF and FFF modes. Despite its substantial weight and limited maximum field size of 25 × 25 cm², GRID-based SFRT offers straightforward treatment planning, efficient dose delivery, and the potential to enhance tumor control through its characteristic peak-to-valley dose distribution.</p>","PeriodicalId":49837,"journal":{"name":"Medical Dosimetry","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2026-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Dosimetry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.meddos.2026.08.006","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Spatially Fractionated Radiation Therapy (SFRT) delivers high-dose radiation in a GRID pattern to treat large tumors. This can be achieved using either a physical GRID block or virtual MLC-based patterns. This report presents our experience commissioning a commercial brass GRID collimator for SFRT. Commissioning was performed using a brass GRID collimator with 6 MV and 10 MV photon beams under both flattening filter (FF) and flattening filter-free (FFF) configurations. Dosimetric measurements were collected in a water phantom and compared with treatment planning system calculations. SFRT test plans were created and validated using a commercial detector array. Valley-to-peak dose ratio (VPDR) ranged from 0.20 to 0.30 (6-MV) and 0.30 to 0.37 (10-MV). The Percent depth doses were lower than those for open fields at all beam energies. Measured vs. calculated profiles agreed within ±5% in dose and 1 mm in distance for all beam energies. TPS-generated plans showed strong agreement with measured distributions, with an average gamma passing rate of 96.5% (3%/3 mm criteria). We successfully commissioned and validated a commercial GRID collimator for SFRT using 6-MV and 10-MV photon beams in both FF and FFF modes. Despite its substantial weight and limited maximum field size of 25 × 25 cm², GRID-based SFRT offers straightforward treatment planning, efficient dose delivery, and the potential to enhance tumor control through its characteristic peak-to-valley dose distribution.

用于空间分割放射治疗的商用黄铜GRID准直器的临床调试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Dosimetry
Medical Dosimetry 医学-核医学
CiteScore
2.40
自引率
0.00%
发文量
51
审稿时长
34 days
期刊介绍: Medical Dosimetry, the official journal of the American Association of Medical Dosimetrists, is the key source of information on new developments for the medical dosimetrist. Practical and comprehensive in coverage, the journal features original contributions and review articles by medical dosimetrists, oncologists, physicists, and radiation therapy technologists on clinical applications and techniques of external beam, interstitial, intracavitary and intraluminal irradiation in cancer management. Articles dealing primarily with physics will be reviewed by a specially appointed team of experts in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书