Development and validation of an integrated wearable system for continuous cardiorespiratory monitoring using photoplethysmography and optical respiratory detection.
IF 3.1 4区 医学Q2 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS
Jesús David Ramírez, Nathalia Toro, Juan Manuel Campo, Guido Gómez-Peña, Julián Antonio Villamarín-Muñoz, Jaime A Mosquera-Sánchez
{"title":"Development and validation of an integrated wearable system for continuous cardiorespiratory monitoring using photoplethysmography and optical respiratory detection.","authors":"Jesús David Ramírez, Nathalia Toro, Juan Manuel Campo, Guido Gómez-Peña, Julián Antonio Villamarín-Muñoz, Jaime A Mosquera-Sánchez","doi":"10.1007/s11517-026-03677-y","DOIUrl":null,"url":null,"abstract":"<p><p>Cardiovascular diseases remain the leading cause of mortality worldwide, with ischaemic heart disease the leading contributor and acute myocardial infarction accounting for the majority of ischaemic heart disease deaths. This study presents the development and technical validation of a low-cost, integrated wearable system for multi-parameter cardiorespiratory monitoring designed to support heart-attack detection algorithms. The system comprises two devices: a wristband incorporating a MAX30105 photoplethysmography sensor for cardiac pulse-wave and SpO[Formula: see text] acquisition, and a chest band featuring novel optical respiratory detection and an MPU6050 inertial measurement unit for respiratory rate and movement monitoring. Both devices use ESP32-C3 microcontrollers with Bluetooth Low Energy connectivity to a custom mobile application enabling real-time visualization and cloud-based storage. Validation was conducted against clinical-grade reference equipment (ADInstruments physiograph and EDAN iM8 monitor) in 43 healthy volunteers, yielding 50 acquisitions: 30 at rest and 20 post-physical activity. This is a technical feasibility study in healthy young volunteers; validation in clinical populations remains future work. Heart rate showed the closest agreement with the reference (percentage error ±1.94%, [Formula: see text] post-activity; limits of agreement [Formula: see text] to 4.21 BPM), followed by respiratory rate (±3.47%, [Formula: see text]). SpO[Formula: see text] error remained within tolerance (1.64% at rest, 2.98% post-activity) but showed weak correlation with the reference owing to range restriction in a healthy cohort, and is not yet suitable for applications requiring absolute saturation values. This study demonstrates that a low-cost, multi-sensor wearable system can achieve accuracy meeting the prespecified feasibility criterion ([Formula: see text]5% error) in a healthy young cohort, establishing technical feasibility as a prerequisite to validation in the cardiovascular patient populations for which the system is ultimately intended.</p>","PeriodicalId":49840,"journal":{"name":"Medical & Biological Engineering & Computing","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2026-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical & Biological Engineering & Computing","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11517-026-03677-y","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0
Abstract
Cardiovascular diseases remain the leading cause of mortality worldwide, with ischaemic heart disease the leading contributor and acute myocardial infarction accounting for the majority of ischaemic heart disease deaths. This study presents the development and technical validation of a low-cost, integrated wearable system for multi-parameter cardiorespiratory monitoring designed to support heart-attack detection algorithms. The system comprises two devices: a wristband incorporating a MAX30105 photoplethysmography sensor for cardiac pulse-wave and SpO[Formula: see text] acquisition, and a chest band featuring novel optical respiratory detection and an MPU6050 inertial measurement unit for respiratory rate and movement monitoring. Both devices use ESP32-C3 microcontrollers with Bluetooth Low Energy connectivity to a custom mobile application enabling real-time visualization and cloud-based storage. Validation was conducted against clinical-grade reference equipment (ADInstruments physiograph and EDAN iM8 monitor) in 43 healthy volunteers, yielding 50 acquisitions: 30 at rest and 20 post-physical activity. This is a technical feasibility study in healthy young volunteers; validation in clinical populations remains future work. Heart rate showed the closest agreement with the reference (percentage error ±1.94%, [Formula: see text] post-activity; limits of agreement [Formula: see text] to 4.21 BPM), followed by respiratory rate (±3.47%, [Formula: see text]). SpO[Formula: see text] error remained within tolerance (1.64% at rest, 2.98% post-activity) but showed weak correlation with the reference owing to range restriction in a healthy cohort, and is not yet suitable for applications requiring absolute saturation values. This study demonstrates that a low-cost, multi-sensor wearable system can achieve accuracy meeting the prespecified feasibility criterion ([Formula: see text]5% error) in a healthy young cohort, establishing technical feasibility as a prerequisite to validation in the cardiovascular patient populations for which the system is ultimately intended.
期刊介绍:
Founded in 1963, Medical & Biological Engineering & Computing (MBEC) continues to serve the biomedical engineering community, covering the entire spectrum of biomedical and clinical engineering. The journal presents exciting and vital experimental and theoretical developments in biomedical science and technology, and reports on advances in computer-based methodologies in these multidisciplinary subjects. The journal also incorporates new and evolving technologies including cellular engineering and molecular imaging.
MBEC publishes original research articles as well as reviews and technical notes. Its Rapid Communications category focuses on material of immediate value to the readership, while the Controversies section provides a forum to exchange views on selected issues, stimulating a vigorous and informed debate in this exciting and high profile field.
MBEC is an official journal of the International Federation of Medical and Biological Engineering (IFMBE).