Fully biodegradable versus nitinol occluder devices for transcatheter patent foramen ovale closure: a systematic review.

Abdulbari Alsaeed, Ahmad R Al-Qudimat, Mohammed Qintar, Raed M Al-Zoubi, Rufaidah H Alameen, Osama Mohamad
{"title":"Fully biodegradable versus nitinol occluder devices for transcatheter patent foramen ovale closure: a systematic review.","authors":"Abdulbari Alsaeed, Ahmad R Al-Qudimat, Mohammed Qintar, Raed M Al-Zoubi, Rufaidah H Alameen, Osama Mohamad","doi":"10.21542/gcsp.2026.34","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> The optimal device platform for transcatheter patent foramen ovale (PFO) closure remains uncertain. Permanent nitinol occluders are widely used, but concerns persist regarding long-term foreign-body exposure and device-related complications. Fully biodegradable occluders have been developed to provide temporary septal support during endothelialization before gradual resorption, with the intended benefit accruing only after the device has resorbed. <b>Methods:</b> We systematically searched Medline, PubMed, Embase, Scopus, Web of Science, the Cochrane Library, and trial registries through 17 February 2026. Eligible studies were randomized or comparative observational studies of patients aged 16 years or older undergoing PFO closure with biodegradable or bioresorbable versus nitinol or metallic occluders. Two reviewers independently screened studies and extracted data. Risk of bias was assessed using RoB 2 for randomized evidence and ROBINS-I for non-randomized evidence. Because of clinical and methodological heterogeneity, findings were synthesized narratively. <b>Results:</b> Three comparative studies were included-one randomized trial and two retrospective cohorts-comprising 481 analyzed participants. Procedural success was high with both device types. Residual shunt generally decreased over time, with no clear advantage for either platform. Serious adverse events, device thrombosis, embolization or detachment, and atrial arrhythmias were uncommon, though event counts were small. Two of the three studies were migraine-specific cohorts, and the randomized trial enrolled a mixed-indication population in which treatment-resistant migraine was the most common single indication; the available evidence therefore reflects device-platform performance predominantly in migraine populations. No study followed participants substantially beyond the expected biodegradation window. <b>Conclusion:</b> Current evidence suggests similar short- to mid-term performance of biodegradable and nitinol occluders, but certainty is low to very low, and no study yet assesses the post-resorption period in which any advantage of a biodegradable platform would be expected to emerge. Larger multicenter studies with standardized imaging, rhythm monitoring, and follow-up extending beyond biodegradation are needed. Because two of the three studies were migraine-specific and event counts were small, these findings should not be extrapolated to stroke-prevention populations, and the absence of observed between-device differences should not be interpreted as equivalence.</p>","PeriodicalId":12669,"journal":{"name":"Global Cardiology Science & Practice","volume":"2026 4","pages":"e202634"},"PeriodicalIF":0.0000,"publicationDate":"2026-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13613138/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global Cardiology Science & Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21542/gcsp.2026.34","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The optimal device platform for transcatheter patent foramen ovale (PFO) closure remains uncertain. Permanent nitinol occluders are widely used, but concerns persist regarding long-term foreign-body exposure and device-related complications. Fully biodegradable occluders have been developed to provide temporary septal support during endothelialization before gradual resorption, with the intended benefit accruing only after the device has resorbed. Methods: We systematically searched Medline, PubMed, Embase, Scopus, Web of Science, the Cochrane Library, and trial registries through 17 February 2026. Eligible studies were randomized or comparative observational studies of patients aged 16 years or older undergoing PFO closure with biodegradable or bioresorbable versus nitinol or metallic occluders. Two reviewers independently screened studies and extracted data. Risk of bias was assessed using RoB 2 for randomized evidence and ROBINS-I for non-randomized evidence. Because of clinical and methodological heterogeneity, findings were synthesized narratively. Results: Three comparative studies were included-one randomized trial and two retrospective cohorts-comprising 481 analyzed participants. Procedural success was high with both device types. Residual shunt generally decreased over time, with no clear advantage for either platform. Serious adverse events, device thrombosis, embolization or detachment, and atrial arrhythmias were uncommon, though event counts were small. Two of the three studies were migraine-specific cohorts, and the randomized trial enrolled a mixed-indication population in which treatment-resistant migraine was the most common single indication; the available evidence therefore reflects device-platform performance predominantly in migraine populations. No study followed participants substantially beyond the expected biodegradation window. Conclusion: Current evidence suggests similar short- to mid-term performance of biodegradable and nitinol occluders, but certainty is low to very low, and no study yet assesses the post-resorption period in which any advantage of a biodegradable platform would be expected to emerge. Larger multicenter studies with standardized imaging, rhythm monitoring, and follow-up extending beyond biodegradation are needed. Because two of the three studies were migraine-specific and event counts were small, these findings should not be extrapolated to stroke-prevention populations, and the absence of observed between-device differences should not be interpreted as equivalence.

经导管卵圆孔未闭闭合的完全可生物降解与镍钛诺封堵器:系统综述。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Global Cardiology Science & Practice
Global Cardiology Science & Practice Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.60
自引率
0.00%
发文量
20
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书