Non-invasive assessment of left atrial activation using lead V8 during Bachmann bundle pacing.

IF 10.2 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Europace Pub Date : 2026-10-01 DOI:10.1093/europace/euag276
Simon Mulier, Arno Fennema, Johan van Koll, Masih Mafi-Rad, Vidal Essebag, Atul Verma, Dominik Linz, Justin Luermans, Kevin Vernooy, Jacqueline Joza
{"title":"Non-invasive assessment of left atrial activation using lead V8 during Bachmann bundle pacing.","authors":"Simon Mulier, Arno Fennema, Johan van Koll, Masih Mafi-Rad, Vidal Essebag, Atul Verma, Dominik Linz, Justin Luermans, Kevin Vernooy, Jacqueline Joza","doi":"10.1093/europace/euag276","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Bachmann bundle pacing (BBP) improves atrial synchrony by advancing LA activation, but quantifying inter-atrial synchronization remains challenging. This study evaluated whether lead V8 reflects posterolateral LA activation time and whether lead V8 can be used to assess the effect of BBP on LA activation.</p><p><strong>Methods and results: </strong>Consecutive patients undergoing an electrophysiology study and ablation (Cohort 1) or BBP lead implantation (Cohort 2) were prospectively enrolled. Surface ECGs were recorded with the V5 electrode repositioned to the V8 location (2 cm below the inferior left scapula). LA activation was determined using the steepest negative downslope of the P-wave (NDAT-P-V8). Iso-V8 was defined as the time from P-wave onset to first positive deflection in lead V8. In Cohort 1, a coronary sinus (CS) catheter invasively determined activation timing at the posterolateral LA (mitral isthmus region). In Cohort 2, NDAT-P-V8 and iso-V8 were used to assess the effect of BBP on LA activation. In Cohort 1 (n = 50), NDAT-P-V8 strongly correlated with the latest CS activation (r = 0.94, P < 0.001). In Cohort 2 (n = 50), lead V8 facilitated intra-procedural assessment of LA activation. IAB was corrected in 20/23 (87%), accompanied by shortening of NDAT-P-V8 (from 120 ± 25 ms to 82 ± 17 ms, P < 0.001) and iso-V8 (from 51 ± 22 ms to 18 ± 17 ms, P < 0.001), consistent with earlier LA activation.</p><p><strong>Conclusion: </strong>NDAT-P-V8 closely reflects the invasively determined timing of the posterolateral LA activation and provides a simple non-invasive marker to assess the effect of BBP on LA activation. Lead V8 may therefore help to assess and optimize atrial activation with BBP.</p>","PeriodicalId":11981,"journal":{"name":"Europace","volume":" ","pages":""},"PeriodicalIF":10.2000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13641076/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Europace","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/europace/euag276","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: Bachmann bundle pacing (BBP) improves atrial synchrony by advancing LA activation, but quantifying inter-atrial synchronization remains challenging. This study evaluated whether lead V8 reflects posterolateral LA activation time and whether lead V8 can be used to assess the effect of BBP on LA activation.

Methods and results: Consecutive patients undergoing an electrophysiology study and ablation (Cohort 1) or BBP lead implantation (Cohort 2) were prospectively enrolled. Surface ECGs were recorded with the V5 electrode repositioned to the V8 location (2 cm below the inferior left scapula). LA activation was determined using the steepest negative downslope of the P-wave (NDAT-P-V8). Iso-V8 was defined as the time from P-wave onset to first positive deflection in lead V8. In Cohort 1, a coronary sinus (CS) catheter invasively determined activation timing at the posterolateral LA (mitral isthmus region). In Cohort 2, NDAT-P-V8 and iso-V8 were used to assess the effect of BBP on LA activation. In Cohort 1 (n = 50), NDAT-P-V8 strongly correlated with the latest CS activation (r = 0.94, P < 0.001). In Cohort 2 (n = 50), lead V8 facilitated intra-procedural assessment of LA activation. IAB was corrected in 20/23 (87%), accompanied by shortening of NDAT-P-V8 (from 120 ± 25 ms to 82 ± 17 ms, P < 0.001) and iso-V8 (from 51 ± 22 ms to 18 ± 17 ms, P < 0.001), consistent with earlier LA activation.

Conclusion: NDAT-P-V8 closely reflects the invasively determined timing of the posterolateral LA activation and provides a simple non-invasive marker to assess the effect of BBP on LA activation. Lead V8 may therefore help to assess and optimize atrial activation with BBP.

巴赫曼束状起搏期间使用V8导联无创评估左心房活动。
背景和目的:巴赫曼束起搏(Bachmann bundle起搏,BBP)通过推进LA激活改善心房同步,但量化心房间同步仍然具有挑战性。本研究评估了V8导联是否反映后外侧LA激活时间,以及V8导联是否可用于评估BBP对LA激活的影响。方法:前瞻性纳入连续接受电生理研究和消融术(队列1)或血脑屏障导联植入(队列2)的患者。将V5电极重新定位到V8位置(左下肩胛骨下2cm)记录表面心电图。使用p波最陡的负下坡(NDAT-P-V8)来确定LA激活。Iso-V8定义为从p波开始到铅V8第一次正偏转的时间。在队列1中,冠状窦(CS)导管侵入性地确定了LA后外侧(二尖瓣峡区)的激活时间。在队列2中,使用NDAT-P-V8和iso-V8来评估BBP对LA激活的影响。结果:在队列1 (n=50)中,NDAT-P-V8与最新的CS激活密切相关(r = 0.94, p)。结论:NDAT-P-V8密切反映了后外侧LA激活的侵袭性确定时间,为评估BBP对LA激活的影响提供了一种简单的非侵入性标志物。因此,导联V8可能有助于评估和优化伴有BBP的心房活动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Europace
Europace 医学-心血管系统
CiteScore
10.30
自引率
8.20%
发文量
851
审稿时长
3-6 weeks
期刊介绍: EP - Europace - European Journal of Pacing, Arrhythmias and Cardiac Electrophysiology of the European Heart Rhythm Association of the European Society of Cardiology. The journal aims to provide an avenue of communication of top quality European and international original scientific work and reviews in the fields of Arrhythmias, Pacing and Cellular Electrophysiology. The Journal offers the reader a collection of contemporary original peer-reviewed papers, invited papers and editorial comments together with book reviews and correspondence.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书