Tozuleristide Fluorescence-Guided Resection of Gliomas: Results of a Phase II Investigator-Initiated Study.

IF 1.4
Rachel C Fox, Xuemo Fan, Adam N Mamelak, Daniel Gomez, Chirag Patil, Ray M Chu, Jeremy Rudnick, Jethro Hu, Elliott M Sina, Keith L Black, Kristi Harrington, John S Yu
{"title":"Tozuleristide Fluorescence-Guided Resection of Gliomas: Results of a Phase II Investigator-Initiated Study.","authors":"Rachel C Fox, Xuemo Fan, Adam N Mamelak, Daniel Gomez, Chirag Patil, Ray M Chu, Jeremy Rudnick, Jethro Hu, Elliott M Sina, Keith L Black, Kristi Harrington, John S Yu","doi":"10.1227/ons.0000000000002203","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>This Phase II, investigator-initiated, nonrandomized clinical trial evaluated tozuleristide, a tumor-specific near-infrared fluorescence imaging agent, combined with the Canvas® imaging system (Blaze Bioscience) to enhance intraoperative visualization of glial tumors.</p><p><strong>Methods: </strong>Subjects with newly diagnosed, suspected, biopsy-proven, or previously resected high- or low-grade central nervous system tumors received 24 mg (contrast-enhancing glioma) or 36 mg (non-contrast-enhancing glioma) of tozuleristide 1 to 24 hours before surgery. Tumors were visualized intraoperatively using the Canvas imaging system. Biopsies were collected to assess tozuleristide sensitivity and specificity by comparing with histopathology assessment. Extent of resection (EOR), calculated from preoperative and postoperative MRI, was compared with historical controls. Fluorescence did not guide resection, and subjects were not selected for maximal EOR.</p><p><strong>Results: </strong>Thirty-nine subjects (33 contrast-enhancing, 6 nonenhancing tumors) underwent all study procedures. Fluorescence was observed in 30/33 contrast-enhancing tumors. Across 191 biopsies, fluorescence showed sensitivity = 0.735, specificity = 0.500, positive predictive value (PPV) = 0.847, negative predictive value = 0.333, and accuracy = 0.685. Residual fluorescence occurred only when total resection was unsafe and showed a nonsignificant negative correlation with EOR (r = -0.318). The mean EOR was 90.09% (24 mg tozuleristide) with 12 subjects achieving gross-total resection; 0/6 nonenhancing tumors fluoresced. Among patients with glioblastoma undergoing repeat resection, exploratory comparison with historical controls showed higher gross-total resection rates in tozuleristide-treated subjects (6/11 vs 2/11, P = .076); however, fluorescence was not incorporated into surgical decision-making, and these results thus cannot be interpreted toward efficacy.</p><p><strong>Conclusion: </strong>Tozuleristide demonstrated tumor-specific fluorescence with high sensitivity and PPV at 24 mg. The high PPV suggests that fluorescence may be useful for confirming tumor presence in enhancing gliomas, but the low negative predictive value seen cannot exclude tumor in the absence of fluorescence, particularly in infiltrative margins. A well-controlled Phase III trial is necessary to determine the efficacy of image-guided resection in improving EOR.</p>","PeriodicalId":520730,"journal":{"name":"Operative neurosurgery (Hagerstown, Md.)","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2026-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operative neurosurgery (Hagerstown, Md.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1227/ons.0000000000002203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objectives: This Phase II, investigator-initiated, nonrandomized clinical trial evaluated tozuleristide, a tumor-specific near-infrared fluorescence imaging agent, combined with the Canvas® imaging system (Blaze Bioscience) to enhance intraoperative visualization of glial tumors.

Methods: Subjects with newly diagnosed, suspected, biopsy-proven, or previously resected high- or low-grade central nervous system tumors received 24 mg (contrast-enhancing glioma) or 36 mg (non-contrast-enhancing glioma) of tozuleristide 1 to 24 hours before surgery. Tumors were visualized intraoperatively using the Canvas imaging system. Biopsies were collected to assess tozuleristide sensitivity and specificity by comparing with histopathology assessment. Extent of resection (EOR), calculated from preoperative and postoperative MRI, was compared with historical controls. Fluorescence did not guide resection, and subjects were not selected for maximal EOR.

Results: Thirty-nine subjects (33 contrast-enhancing, 6 nonenhancing tumors) underwent all study procedures. Fluorescence was observed in 30/33 contrast-enhancing tumors. Across 191 biopsies, fluorescence showed sensitivity = 0.735, specificity = 0.500, positive predictive value (PPV) = 0.847, negative predictive value = 0.333, and accuracy = 0.685. Residual fluorescence occurred only when total resection was unsafe and showed a nonsignificant negative correlation with EOR (r = -0.318). The mean EOR was 90.09% (24 mg tozuleristide) with 12 subjects achieving gross-total resection; 0/6 nonenhancing tumors fluoresced. Among patients with glioblastoma undergoing repeat resection, exploratory comparison with historical controls showed higher gross-total resection rates in tozuleristide-treated subjects (6/11 vs 2/11, P = .076); however, fluorescence was not incorporated into surgical decision-making, and these results thus cannot be interpreted toward efficacy.

Conclusion: Tozuleristide demonstrated tumor-specific fluorescence with high sensitivity and PPV at 24 mg. The high PPV suggests that fluorescence may be useful for confirming tumor presence in enhancing gliomas, but the low negative predictive value seen cannot exclude tumor in the absence of fluorescence, particularly in infiltrative margins. A well-controlled Phase III trial is necessary to determine the efficacy of image-guided resection in improving EOR.

Tozuleristide荧光引导胶质瘤切除术:一项II期研究的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书