Proof-of-Concept Study of Task-Based Adaptive SPECT Imaging via System Sampling Strategies on a 12-Head Robotic SPECT Platform.

Yifei Jin, Ling-Jian Meng
{"title":"Proof-of-Concept Study of Task-Based Adaptive SPECT Imaging via System Sampling Strategies on a 12-Head Robotic SPECT Platform.","authors":"Yifei Jin, Ling-Jian Meng","doi":"10.1109/TMI.2026.3733006","DOIUrl":null,"url":null,"abstract":"<p><p>In this work, we explored a computational framework for task-based adaptive SPECT imaging based on a robotic platform. The framework has two key components. First, we utilized the modified uniform Cramér-Rao bound (MUCRB) to approximate the imaging variance attainable with a given system configuration characterized by the imaging time distribution (ITD) over a discretized system configuration space. Second, we developed a computational approach to enable direct optimization of the ITD (and the associated system configuration) to achieve a minimum imaging variance. To enable efficient system optimization, a convex surrogate of the MUCRB-based variance metric was derived, and a non-uniform object-space pixelation (NUOP) strategy was introduced to reduce computational load, while preserving resolution within regions of interest (ROIs). This framework was evaluated using simulation studies with a 12-camera-head robotic SPECT system. We used several phantoms and a series of performance measures to demonstrate the effectiveness of the adaptive imaging strategy. For the brain phantom, the adapted ITD reduced RMSE from 859.0 to 734.3. For the hot-rod phantom, RMSE was reduced from 1411.9/1316.5 to 1191.2/1138.0 across the two ROIs, while CRC increased from 0.092/0.351 to 0.181/0.604. For the cold-rod phantom, RMSE was reduced from 720.0/691.1 to 603.5/587.4 across the two ROIs relative to whole-view ITD, while CRC increased from 0.069/0.150 to 0.373/0.499. These results demonstrated that the proposed framework enables efficient, task-specific optimization of acquisition strategies and significantly improved ROI image quality.</p>","PeriodicalId":94033,"journal":{"name":"IEEE transactions on medical imaging","volume":"PP ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TMI.2026.3733006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this work, we explored a computational framework for task-based adaptive SPECT imaging based on a robotic platform. The framework has two key components. First, we utilized the modified uniform Cramér-Rao bound (MUCRB) to approximate the imaging variance attainable with a given system configuration characterized by the imaging time distribution (ITD) over a discretized system configuration space. Second, we developed a computational approach to enable direct optimization of the ITD (and the associated system configuration) to achieve a minimum imaging variance. To enable efficient system optimization, a convex surrogate of the MUCRB-based variance metric was derived, and a non-uniform object-space pixelation (NUOP) strategy was introduced to reduce computational load, while preserving resolution within regions of interest (ROIs). This framework was evaluated using simulation studies with a 12-camera-head robotic SPECT system. We used several phantoms and a series of performance measures to demonstrate the effectiveness of the adaptive imaging strategy. For the brain phantom, the adapted ITD reduced RMSE from 859.0 to 734.3. For the hot-rod phantom, RMSE was reduced from 1411.9/1316.5 to 1191.2/1138.0 across the two ROIs, while CRC increased from 0.092/0.351 to 0.181/0.604. For the cold-rod phantom, RMSE was reduced from 720.0/691.1 to 603.5/587.4 across the two ROIs relative to whole-view ITD, while CRC increased from 0.069/0.150 to 0.373/0.499. These results demonstrated that the proposed framework enables efficient, task-specific optimization of acquisition strategies and significantly improved ROI image quality.

12头机器人SPECT平台上基于任务的自适应SPECT成像系统采样策略的概念验证研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书