{"title":"Associations and condition sensitivity of smartphone-and force-plate-derived sway metrics during VR-CTSIB.","authors":"Saeed Eshghi, Amin Mohammadi, Eric Schussler, Ryan S McCann","doi":"10.1088/2057-1976/aeac32","DOIUrl":null,"url":null,"abstract":"<p><p>Smartphone-based sensors may provide a complement to laboratory-based force-plate balance assessment; however, validation studies have not established whether smartphone-force-plate associations and agreement vary across combined manipulations of visual input and support-surface reliability, or which smartphone-derived metrics are most sensitive to sensory challenges. Therefore, this study compared smartphone-derived and force-plate-derived sway metrics during virtual reality-based clinical test of sensory interaction and balance (VR-CTSIB) conditions. This secondary analysis included 40 adults (20 with chronic ankle instability and 20 healthy controls). Participants completed 30 s double-leg stance trials under six VR-CTSIB conditions combining firm or foam surfaces with NormVision, DisplayOff, and SwayRef visual environments. Sway data were collected using a force plate and a smartphone-based head-mounted display. Root mean square (RMS) and mean absolute value (MAV) were calculated in the mediolateral (ML) and anterior-posterior (AP) directions. Pearson correlations with false discovery rate (FDR) correction were used to examine device associations, Bland-Altman analyses assessed agreement, and Cohen's<i>dz</i>quantified condition sensitivity. In the primary analyses, ML smartphone metrics showed larger correlation coefficients with force-plate measures than AP metrics. The largest correlations were observed in the firm NormVision condition for ML RMS with force-plate ML velocity RMS (<i>r</i>= 0.705, FDR-adjusted<i>p</i>< 0.001) and ML MAV with force-plate ML velocity MAV (<i>r</i>= 0.679, FDR-adjusted<i>p</i>< 0.001). Force-plate outcomes demonstrated greater condition sensitivity than smartphone-derived outcomes. Among smartphone metrics, ML MAV and RMS in the SwayRef condition showed the largest effects (<i>dz</i>= 0.895 and 0.876, respectively). Bland-Altman analyses showed systematic bias, with agreement varying across metrics and conditions. Overall, smartphone-derived sway metrics may provide complementary information during VR-based balance assessment, particularly in the ML direction. However, associations, agreement, and condition sensitivity varied by metric and sensory condition, indicating that smartphone- and force-plate-derived measures should not be interpreted as interchangeable.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2026-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/aeac32","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Smartphone-based sensors may provide a complement to laboratory-based force-plate balance assessment; however, validation studies have not established whether smartphone-force-plate associations and agreement vary across combined manipulations of visual input and support-surface reliability, or which smartphone-derived metrics are most sensitive to sensory challenges. Therefore, this study compared smartphone-derived and force-plate-derived sway metrics during virtual reality-based clinical test of sensory interaction and balance (VR-CTSIB) conditions. This secondary analysis included 40 adults (20 with chronic ankle instability and 20 healthy controls). Participants completed 30 s double-leg stance trials under six VR-CTSIB conditions combining firm or foam surfaces with NormVision, DisplayOff, and SwayRef visual environments. Sway data were collected using a force plate and a smartphone-based head-mounted display. Root mean square (RMS) and mean absolute value (MAV) were calculated in the mediolateral (ML) and anterior-posterior (AP) directions. Pearson correlations with false discovery rate (FDR) correction were used to examine device associations, Bland-Altman analyses assessed agreement, and Cohen'sdzquantified condition sensitivity. In the primary analyses, ML smartphone metrics showed larger correlation coefficients with force-plate measures than AP metrics. The largest correlations were observed in the firm NormVision condition for ML RMS with force-plate ML velocity RMS (r= 0.705, FDR-adjustedp< 0.001) and ML MAV with force-plate ML velocity MAV (r= 0.679, FDR-adjustedp< 0.001). Force-plate outcomes demonstrated greater condition sensitivity than smartphone-derived outcomes. Among smartphone metrics, ML MAV and RMS in the SwayRef condition showed the largest effects (dz= 0.895 and 0.876, respectively). Bland-Altman analyses showed systematic bias, with agreement varying across metrics and conditions. Overall, smartphone-derived sway metrics may provide complementary information during VR-based balance assessment, particularly in the ML direction. However, associations, agreement, and condition sensitivity varied by metric and sensory condition, indicating that smartphone- and force-plate-derived measures should not be interpreted as interchangeable.

VR-CTSIB期间智能手机和力板衍生的摇摆指标的关联和条件敏感性。
基于智能手机的传感器可以为基于实验室的力板平衡评估提供补充;然而,验证研究尚未确定智能手机-力-板的关联和一致性是否在视觉输入和支撑面可靠性的组合操作中有所不同,或者哪种智能手机衍生的指标对感官挑战最敏感。因此,本研究在基于虚拟现实的感觉相互作用和平衡临床测试(VR-CTSIB)条件下,比较了智能手机衍生和力板衍生的摇摆指标。这项二次分析包括40名成年人(20名患有慢性踝关节不稳定(CAI), 20名健康对照)。参与者在六种VR-CTSIB条件下完成了30秒的双腿站立试验,包括坚固或泡沫表面与NormVision, DisplayOff和SwayRef视觉环境。Sway数据是通过测力板和基于智能手机的头戴式显示器收集的。计算中外侧(ML)和前后(AP)方向的均方根(RMS)和平均绝对值(MAV)。Pearson相关性与错误发现率校正用于检查器械相关性,Bland-Altman分析评估一致性,Cohen的dz量化病情敏感性。在初步分析中,ML智能手机指标与力板指标的相关系数大于AP指标。在公司NormVision条件下,中外侧RMS与力板中外侧速度RMS的相关性最大(r = 0.705, fdr校正p < 0.001), ML MAV与力板ML速度MAV的相关性最大(r = 0.679, fdr校正p < 0.001)。力板结果显示出比智能手机结果更高的条件敏感性。在智能手机指标中,SwayRef条件下的ML MAV和RMS的影响最大(dz分别= 0.895和0.876)。Bland-Altman分析显示出系统性偏差,在不同的指标和条件下,一致性有所不同。总的来说,智能手机衍生的摇摆指标可以在基于虚拟现实的平衡评估中提供补充信息,特别是在ML方向上。然而,关联、一致性和条件敏感性因度量和感官条件而异,这表明智能手机和力板衍生的测量不应被解释为可互换。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedical Physics & Engineering Express
Biomedical Physics & Engineering Express RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.80
自引率
0.00%
发文量
153
期刊介绍: BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书