Compression Suture Staple Repair of Simulated Gluteus Medius Partial Tendon Tears Provides Increased Contact Pressure Compared With Stepwise Bridged Repair.

Q3 Medicine
Arthroscopy Sports Medicine and Rehabilitation Pub Date : 2026-09-22 eCollection Date: 2026-10-01 DOI:10.1002/ars2.70079
J Houston Dove, David P Beason, Glenn S Fleisig, Benton A Emblom
{"title":"Compression Suture Staple Repair of Simulated Gluteus Medius Partial Tendon Tears Provides Increased Contact Pressure Compared With Stepwise Bridged Repair.","authors":"J Houston Dove, David P Beason, Glenn S Fleisig, Benton A Emblom","doi":"10.1002/ars2.70079","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To examine the contact mechanics of 2 different suture anchor configuration constructs for gluteus medius repair in partial-thickness tears and to define an optimal distance for anchor placement in a biomechanical model.</p><p><strong>Methods: </strong>Trochanteric bone was simulated using polyurethane foam blocks, and a polyurethane rubber was used as a surrogate for the gluteus medius tendon tissue. As the rubber remained partially attached to the foam, this design simulated a partial-thickness tear without any retraction of the tendon tissue. A pressure sensor was used to collect contact data. Repairs were performed with knotless suture anchors. Three different 2-anchor repair interval distances (10, 15, and 20 mm) were first tested to define the optimal distance for anchor placement. We then performed 2 different 3-anchor repairs (stepwise bridged and compression suture staple) using the optimal distance. Pressure data were collected and compared between 3-anchor groups.</p><p><strong>Results: </strong>Results from the 2-anchor interval distance testing showed an overall significant effect for contact force (<i>P</i> < .001), area (<i>P</i> < .001), and pressure (<i>P</i> = .01), with 15 mm being the optimal distance to exert the most pressure. Results from the 3-anchor testing at 15 mm between anchors showed that contact pressure on the surrogate tendon was significantly (<i>P</i> = .04) greater for the compression suture staple technique (208.5 ± 61.6 kPa) compared with the stepwise bridged technique (143.4 ± 41.4 kPa).</p><p><strong>Conclusions: </strong>In this biomechanical study, the compression suture staple technique exerted more pressure than the stepwise bridged repair technique at time 0 with no cyclic loading. Additionally, 15 mm had the greatest contact pressure of those examined for anchor placement using knotless suture anchors for these repairs.</p><p><strong>Clinical relevance: </strong>By studying the contact mechanics of different suture anchor configurations, we determined which setup may provide better compression of the tendon onto the bone.</p>","PeriodicalId":34631,"journal":{"name":"Arthroscopy Sports Medicine and Rehabilitation","volume":" ","pages":"e70079"},"PeriodicalIF":0.0000,"publicationDate":"2026-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13596692/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthroscopy Sports Medicine and Rehabilitation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/ars2.70079","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/10/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To examine the contact mechanics of 2 different suture anchor configuration constructs for gluteus medius repair in partial-thickness tears and to define an optimal distance for anchor placement in a biomechanical model.

Methods: Trochanteric bone was simulated using polyurethane foam blocks, and a polyurethane rubber was used as a surrogate for the gluteus medius tendon tissue. As the rubber remained partially attached to the foam, this design simulated a partial-thickness tear without any retraction of the tendon tissue. A pressure sensor was used to collect contact data. Repairs were performed with knotless suture anchors. Three different 2-anchor repair interval distances (10, 15, and 20 mm) were first tested to define the optimal distance for anchor placement. We then performed 2 different 3-anchor repairs (stepwise bridged and compression suture staple) using the optimal distance. Pressure data were collected and compared between 3-anchor groups.

Results: Results from the 2-anchor interval distance testing showed an overall significant effect for contact force (P < .001), area (P < .001), and pressure (P = .01), with 15 mm being the optimal distance to exert the most pressure. Results from the 3-anchor testing at 15 mm between anchors showed that contact pressure on the surrogate tendon was significantly (P = .04) greater for the compression suture staple technique (208.5 ± 61.6 kPa) compared with the stepwise bridged technique (143.4 ± 41.4 kPa).

Conclusions: In this biomechanical study, the compression suture staple technique exerted more pressure than the stepwise bridged repair technique at time 0 with no cyclic loading. Additionally, 15 mm had the greatest contact pressure of those examined for anchor placement using knotless suture anchors for these repairs.

Clinical relevance: By studying the contact mechanics of different suture anchor configurations, we determined which setup may provide better compression of the tendon onto the bone.

与逐步桥接修复相比,加压缝合钉钉修复模拟臀中肌腱部分撕裂提供了更高的接触压力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.70
自引率
0.00%
发文量
218
审稿时长
45 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书